Solid-state tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on ionic liquid/sol-gel titania/Nafion composite film

被引:13
|
作者
Jang, Junho [1 ]
Lee, Won-Yong [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
Chemiluminescence; ECL; Ionic liquid; Sol-gel titania; Composite film; DANSYL AMINO-ACIDS; MODIFIED ELECTRODE; BETA-BLOCKERS; ELECTROCHEMILUMINESCENCE; CHROMATOGRAPHY; NAFION; TRIS(2,2'-BIPYRIDINE)RUTHENIUM(II); TRIS(2,2-BIPYRIDYL)RUTHENIUM(II); ELECTROCHEMISTRY; RUTHENIUM;
D O I
10.1016/j.jelechem.2014.10.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of being able to control the selectivity of solid-state tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrogenerated chemiluminescence (ECL) sensor is proposed by selecting ionic liquids with appropriate hydrophobicity in the sol-gel titania/Nafion composite film. Four different kinds of ionic liquids with different hydrophobicity such as 1-butyl-3-methylimidazolium hexafluorophosphate (BMImPF(6)), 1-ethyl-3-methylimidazolium hexafluorophosphate (EMImPF(6)), 1-hexyl-3-methylimidazolium hexafluorophosphate (HMImPF(6)), 1-benzyl-3-methylimidazolium hexafluorophosphate (BnMImPF(6)) were incorporated in the sol-gel titania/Nafion composite films. The sequence of the observed ECL intensities for hydrophobic analytes is closely related to the sequence of the hydrophobicity of the ionic liquids used in the composite-based ECL sensor. In contrast, the observed ECL sequence for hydrophilic analytes such as ascorbic acid and oxalate is the opposite to the sequence of the hydrophobicity of the ionic liquids used in the composite film. Due to the decreased electron transfer resistance in the ionic liquid-based sol gel titania/Nafion composite films, the present ECL sensor based on the BMImPF(6)/titania/Nafion composite film gave a remarkable detection limit (S/N = 3) of 0.48 nM for TPA. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [1] Tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence ethanol biosensor based on ionic liquid doped titania-Nafion composite film
    Yang, Yuna
    Nam, Sungju
    Lee, Won-Yong
    MICROCHEMICAL JOURNAL, 2018, 142 : 62 - 69
  • [2] Tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films
    Choi, HN
    Lee, JY
    Lyu, YK
    Lee, WY
    ANALYTICA CHIMICA ACTA, 2006, 565 (01) : 48 - 55
  • [3] Solid-state Electrogenerated Chemiluminescence Based on Semiconductor Nanocrystals and Tris(2,2′-bipyridyl) Ruthenium(II) Complex
    Kargbo, Osman
    Ding, Shou-Nian
    Li, Qi-Le
    CURRENT ANALYTICAL CHEMISTRY, 2014, 10 (04) : 622 - 634
  • [4] One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film
    Lee, Sang Jung
    Lee, Don Hui
    Lee, Won-Yong
    SENSORS, 2022, 22 (08)
  • [5] Sol-gel-immobilized Tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor for high-performance liquid chromatography
    Choi, HN
    Cho, SH
    Park, YJ
    Lee, DW
    Lee, WY
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 49 - 56
  • [6] Electrogenerated chemiluminescence biosensor with alcohol dehydrogenase and tris(2,2′-bipyridyl)ruthenium (II) immobilized in sol-gel hybrid material
    Xu, ZA
    Guo, ZH
    Dong, SJ
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (03): : 455 - 461
  • [7] Electrogene rated Chemiluminescence Sensor Based on Tris(2,2′-bipyridyl) ruthenium(II) Immobilized in the Composite Film of Multi-walled Carbon Nanotube/Sol-gel Zinc oxide/Nafion
    Choi, Eun Jung
    Kang, Chang Hoon
    Choi, Han Nim
    Lee, Won-Yong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2009, 30 (10): : 2387 - 2392
  • [8] Solid-supported chemiluminescence and electrogenerated chemiluminescence based on a tris(2,2′-bipyridyl)ruthenium(II) derivative
    Greenway, GM
    Greenwood, A
    Watts, P
    Wiles, C
    CHEMICAL COMMUNICATIONS, 2006, (01) : 85 - 87
  • [9] Coreactants of tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence
    Yuan, Yali
    Han, Shuang
    Hu, Lianzhe
    Parveen, Saima
    Xu, Guobao
    ELECTROCHIMICA ACTA, 2012, 82 : 484 - 492
  • [10] Tris (2,2′-bipyridyl) ruthenium (II) electrogeuerated chemiluminescence sensor based on sol-gel-derived V2O5/Nafion composite films
    Choi, HN
    Lyu, YK
    Lee, WY
    ELECTROANALYSIS, 2006, 18 (03) : 275 - 281