Effect of blood and microbubble oxygen and nitrogen content on perfluorocarbon-filled dextrose albumin microbubble size and efficacy: In vitro and in vivo studies

被引:13
|
作者
Porter, T [1 ]
Kricsfeld, D [1 ]
Cheatham, S [1 ]
Li, SP [1 ]
机构
[1] Univ Nebraska, Med Ctr, Cardiol Sect, Omaha, NE 68198 USA
关键词
D O I
10.1016/S0894-7317(98)70020-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We hypothesized, on the basis of in vitro observations, that a higher oxygen partial pressure within perfluorocarbon-containing microbubbles (PCMB) would enhance inward nitrogen diffusion after venous injection, leading to improved myocardial contrast. The in vitro studies measured PCMB size and concentration after injection into arterial blood that was obtained during inhalation of either room air or 100% oxygen. We then compared the myocardial contrast produced from PCMB sonicated in the presence of either a nitrogen-free environment (100% oxygen) or room air in three closed chest dogs. PCMB exposed to oxygenated blood in vitro were significantly smaller after insonation than PCMB exposed to arterial blood obtained during room air inhalation, confirming the important role of dissolved nitrogen in stabilizing PCMB size. In vivo studies demonstrated that intravenous PCMB sonicated with 100% oxygen produced significantly greater anterior and posterior myocardial contrast than PCMB sonicated in the presence of room air.
引用
收藏
页码:421 / 425
页数:5
相关论文
共 4 条
  • [1] EFFECT OF ALBUMIN AND DEXTROSE CONCENTRATION ON ULTRASOUND AND MICROBUBBLE MEDIATED GENE TRANSFECTION IN VIVO
    Browning, Richard J.
    Mulvana, Helen
    Tang, Meng-Xing
    Hajnal, Jo V.
    Wells, Dominic J.
    Eckersley, Robert J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (06): : 1067 - 1077
  • [2] Optimization of the size distribution and myocardial contrast effect of perfluorocarbon-filled albumin microbubbles by lyophilization under continuous negative pressure
    Chen, SY
    Wang, ZW
    Zhou, YT
    Grayburn, PA
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (08) : 748 - 753
  • [3] The effect of ultrasound frame rate on perfluorocarbon-exposed sonicated dextrose albumin microbubble size and concentration when insonifying at different flow rates, transducer frequencies, and acoustic outputs
    Porter, TR
    Kricsfeld, D
    Cheatham, S
    Li, SP
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (06) : 593 - 601
  • [4] Studies on the effect of high oxygen pressure II. Effect of high oxygen pressure on the sugar, phosphorus, non-protein nitrogen, chloride, creatinin, calcium and potassium content of the blood
    Shilling, CW
    Thomson, RM
    Behnke, AR
    Shaw, LA
    Messer, AC
    AMERICAN JOURNAL OF PHYSIOLOGY, 1934, 107 (01): : 29 - 36