Diagnostic accuracy of 18F-PSMA-1007 PET/CT for prostate 18 cancer in primary staging and biochemical recurrence with different serum PSA levels: A systematic review and meta- analysis

被引:0
|
作者
Liu, Xue [1 ]
Wang, Qi [2 ]
Zhang, Bao [3 ]
Jiang, Tao [3 ]
Zeng, Wenbing [1 ]
机构
[1] Chongqing Univ Three Gorges Hosp, PET CT Ctr, 165 Xincheng Rd, Chongqing 404000, Peoples R China
[2] Jishou Univ, Sch Med, Jishou, Hunan, Peoples R China
[3] First Pepoles Hosp Huaihua City, Dept Nucl Med, 144 Jinxi South Rd, Huaihua 418000, Hunan, Peoples R China
关键词
Prostate cancer; Biochemical recurrence; F-18-PSMA-1007; Meta-analysis; PET; GA-68-PSMA-11; METAANALYSIS; TOMOGRAPHY; BIAS;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We performed a systematic review and meta-analysis to evaluate the application value of flu-orine-18-prostate specific membrane antigen (F-18-PSMA-1007) positron emission tomography/computed to-mography (PET/CT) in patients with different serum prostate specific antigen (PSA) levels and primary pros-tate cancer (PCa) or the biochemical recurrence of Pca. Methods: A comprehensive electronic literature se-arch of the PubMed, Embase and Cochrane Library databases was conducted in accordance with the PRISMA statement. We calculated the pooled sensitivity and specificity of F-PSMA-1007 PET/CT in PCa. A summary 18 receiver operator characteristic (SROC) curve and the area under the curve (AUC) were used to assess the accuracy of F-18-PSMA-1007 PET/CT for PCa. Results: The final analysis included 11 studies that described 799 18 patients and 4261 lesions with F-18-PSMA-1007 PET/CT in PCa. The pooled sensitivity and specificity of F-18-PS -18 18 MA-1007 PET/CT in PCa were 0.836 and 0.946, respectively. The per-patient pooled sensitivity and specificity of F-PSMA-1007 PET/CT in PCa were 0.934 and 0.453, and the per-lesion values were 0.816 and 0.979, res -18 pectively. The pooled sensitivity and specificity of F-PSMA-1007 PET/CT in PCa with PSA>2ng/mL were 18 0.923 and 0.442 in a patient-based analysis and 0.799 and 0.961 in a lesion-based analysis, respectively. The pooled sensitivity and specificity of F-18-PSMA-1007 PET/CT in PCa with PSA<2ng/mL were 0.832 and 0.277 in 18 a patient-based analysis, respectively. Conclusion: This meta-analysis showed that F-PSMA-1007 PET/CT 18 has a higher diagnostic value for prostate cancer in the setting of primary PCa and biochemical recurrence. As serum PSA levels increase, the diagnostic accuracy of F-18-PSMA-1007 PET/CT also improves. 18
引用
收藏
页码:88 / 102
页数:15
相关论文
共 50 条
  • [1] Diagnostic Role of 18F-PSMA-1007 PET/CT in Prostate Cancer Staging: A Systematic Review
    Awenat, Salam
    Piccardo, Arnoldo
    Carvoeiras, Patricia
    Signore, Giovanni
    Giovanella, Luca
    Prior, John O.
    Treglia, Giorgio
    DIAGNOSTICS, 2021, 11 (03)
  • [2] Diagnostic Accuracy of 18F-PSMA-1007 PET/CT Imaging for Lymph Node Staging of Prostate Carcinoma in Primary and Biochemical Recurrence
    Sprute, Katharina
    Kramer, Vasko
    Koerber, Stefan A.
    Meneses, Manuel
    Fernandez, Rene
    Soza-Ried, Cristian
    Eiber, Mathias
    Weber, Wolfgang A.
    Rauscher, Isabel
    Rahbar, Kambiz
    Schaefers, Michael
    Watabe, Tadashi
    Uemura, Motohide
    Naka, Sadahiro
    Nonomura, Norio
    Hatazawa, Jun
    Schwab, Constantin
    Schuetz, Viktoria
    Hohenfellner, Markus
    Holland-Letz, Tim
    Debus, Juergen
    Kratochwil, Clemens
    Amaral, Horacio
    Choyke, Pete L.
    Haberkorn, Uwe
    Sandoval, Camilo
    Giesel, Frederik L.
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (02) : 208 - 213
  • [3] Diagnostic accuracy of [18F]PSMA-1007 PET/CT in biochemical recurrence of prostate cancer
    Mingels, Clemens
    Bohn, Karl Peter
    Rominger, Axel
    Afshar-Oromieh, Ali
    Alberts, Ian
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (07) : 2436 - 2444
  • [4] Diagnostic accuracy of [18F]PSMA-1007 PET/CT in biochemical recurrence of prostate cancer
    Clemens Mingels
    Karl Peter Bohn
    Axel Rominger
    Ali Afshar-Oromieh
    Ian Alberts
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 2436 - 2444
  • [5] Diagnostic Efficacy of 18F-PSMA-1007 in Staging of Prostate Cancer
    Gourevich, K.
    Koskosi, A.
    Keidar, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S598 - S598
  • [6] Diagnostic performance of 18F-PSMA-1007 PET/CT in patients with biochemical recurrent prostate cancer
    Kambiz Rahbar
    Ali Afshar-Oromieh
    Robert Seifert
    Stefan Wagner
    Michael Schäfers
    Martin Bögemann
    Matthias Weckesser
    European Journal of Nuclear Medicine and Molecular Imaging, 2018, 45 : 2055 - 2061
  • [7] Diagnostic performance of 18F-PSMA-1007 PET/CT in patients with biochemical recurrent prostate cancer
    Rahbar, Kambiz
    Afshar-Oromieh, Ali
    Seifert, Robert
    Wagner, Stefan
    Schaefers, Michael
    Boegemann, Martin
    Weckesser, Matthias
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (12) : 2055 - 2061
  • [8] Diagnostic accuracy of 18F-PSMA-1007-PET/CT imaging for lymph node staging in prostate carcinoma in primary and biochemical recurrence
    Sprute, K.
    Kramer, V.
    Koerber, S.
    Meneses, M.
    Fernandez, R.
    Soza-Ried, C.
    Eiber, M.
    Weber, W.
    Rauscher, I.
    Rhabar, K.
    Schaefers, M.
    Watabe, T.
    Uemura, M.
    Naka, S.
    Nonomura, N.
    Hatazawa, J.
    Schwab, C.
    Schuetz, V.
    Hohenfellner, M.
    Holland-Letz, T.
    Debus, J.
    Kratochwil, C.
    Amaral, H.
    Chokyke, P.
    Haberkorn, U.
    Sandoval, C.
    Giesel, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S362 - S363
  • [9] Supraclavicular nodal metastasis at primary staging of prostate cancer using 18F-PSMA-1007 PET/CT
    Gitau, Samuel Nguku
    Shah, Jasmit
    Olwit, William
    Saeed, Samnakay
    Mansour, Manel Haj
    Makhdomi, Khalid
    EJNMMI REPORTS, 2025, 9 (01)
  • [10] 18F-PSMA-1007 PET in Biochemical Recurrent Prostate Cancer: An Updated Meta-Analysis
    Ferrari, Matteo
    Treglia, Giorgio
    CONTRAST MEDIA & MOLECULAR IMAGING, 2021, 2021