Comparison of load shifting incentives for low-energy buildings with heat pumps to attain grid flexibility benefits

被引:78
|
作者
Patteeuw, Dieter [1 ,3 ]
Henze, Gregor P. [2 ]
Helsen, Lieve [1 ,3 ]
机构
[1] Katholieke Univ Leuven, Div Appl Mech & Energy Convers, Dept Mech Engn, KU Leuven Energy Inst, Celestijnenlaan 300 Box 2420, B-3001 Leuven, Belgium
[2] Univ Colorado, Dept Civil Environm & Architectural Engn, Boulder, CO 80309 USA
[3] EnergyVille, Thor Pk, Waterschei, Belgium
关键词
Electricity price; Direct load control; Heat pump; Load shifting; Electricity generation; Integrated assessment model; ACTIVE DEMAND RESPONSE; WIND POWER INTEGRATION; SIDE MANAGEMENT; MODEL; SYSTEMS;
D O I
10.1016/j.apenergy.2016.01.036
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper aims at assessing the value of load shifting and demand side flexibility for improving electric grid system operations. In particular, this study investigates to what extent residential heat pumps participating in load shifting can contribute to reducing operational costs and CO2 emissions associated with electric power generation and how home owners with heat pump systems can be best motivated to achieve these flexibility benefits. Residential heat pumps, when intelligently orchestrated in their operation, can lower operational costs and CO2 emissions by performing load shifting in order to reduce curtailment of electricity from renewable energy sources and improve the efficiency of dispatchable power plants. In order to study the interaction, both the electricity generation system and residences with heat pumps are modeled. In a first step, an integrated modeling approach is presented which represents the idealized case where the electrical grid operation in terms of unit commitment and dispatch is concurrently optimized with that of a large number of residential heat pumps located in homes designed to low-energy design standards. While this joint optimization approach does not lend itself for real-time implementation, it serves as an upper bound for the achievable operational cost savings. The main focus of this paper is to assess to what extent load shifting incentives are able to achieve the aforementioned savings potential. Two types of incentives are studied: direct load control and dynamic time-of-use pricing. Since both the electricity generation supply system and the residential building stock with heat pumps had been modeled for the joint optimization, the performance of both load shifting incentives can be compared by separately assessing the supply and demand side. Superior performance is noted for the direct-load control scenario, achieving 60-90% of the cost savings attained in the jointly optimized best-case scenario. In dynamic time-of-use pricing, poor performance in terms of reduced cost and emissions is noted when the heat pumps response is not taken into account. When the heat pumps response is taken into account, dynamic time-of-use pricing performs better. However, both dynamic time-of-use pricing schemes show inferior performance at high levels of residential heat pump penetration. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:80 / 92
页数:13
相关论文
共 46 条
  • [1] Operation and energy flexibility evaluation of direct load controlled buildings equipped with heat pumps
    Mor, Gerard
    Cipriano, Jordi
    Grillone, Benedetto
    Amblard, Frederic
    Menon, Ramanunni Parakkal
    Page, Jessen
    Brennenstuhl, Marcus
    Pietruschka, Dirk
    Baumer, Ruben
    Eicker, Ursula
    ENERGY AND BUILDINGS, 2021, 253
  • [2] Increasing Economic Benefits by Load-Shifting of Electrical Heat Pumps
    Laveyne, Joannes I.
    Zwaenepoel, Brecht
    Van Eetvelde, Greet
    Vandevelde, Lieven
    PRES 2014, 17TH CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1-3, 2014, 39 : 1513 - +
  • [3] Heating system energy flexibility of low-energy residential buildings
    Foteinaki, Kyriaki
    Li, Rongling
    Heller, Alfred
    Rode, Carsten
    ENERGY AND BUILDINGS, 2018, 180 : 95 - 108
  • [4] Assessing the Demand Side Management Potential and the Energy Flexibility of Heat Pumps in Buildings
    Arteconi, Alessia
    Polonara, Fabio
    ENERGIES, 2018, 11 (07):
  • [5] A performance comparison of passive and low-energy buildings
    Mahdavi, Ardeshir
    Doppelbauer, Eva-Maria
    ENERGY AND BUILDINGS, 2010, 42 (08) : 1314 - 1319
  • [6] Evaluation of energy flexibility of low-energy residential buildings connected to district heating
    Foteinaki, Kyriaki
    Li, Rongling
    Pean, Thibault
    Rode, Carsten
    Salom, Jaume
    ENERGY AND BUILDINGS, 2020, 213
  • [7] A review on chemisorption heat storage in low-energy buildings
    Kuznik, Frederic
    Johannes, Kevyn
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 2333 - 2341
  • [8] Economic and environmental benefits of low-cost passive low-energy buildings
    Zhou Z.
    Li C.
    Wang L.
    Cole D.
    Zhou, Z. (jasonwjoe@sina.com), 1600, Eastern Macedonia and Thrace Institute of Technology (09): : 27 - 33
  • [9] Energy system and cost impacts of heat supply to low-energy buildings in Sweden
    Sandvall, Akram
    Karlsson, Kenneth B.
    ENERGY, 2023, 268
  • [10] Assessment of the thermal energy flexibility of residential buildings with heat pumps under various electric tariff designs
    Wilczynski, Eric John
    Chambers, Jonathan
    Patel, Martin K.
    Worrell, Ernst
    Pezzutto, Simon
    ENERGY AND BUILDINGS, 2023, 294