Proprioceptive assessment of the wrist joint across both joint degrees of freedom

被引:0
|
作者
Cuppone, A. [1 ]
Squeri, V. [1 ]
Semprini, M. [2 ]
Konczak, J. [3 ,4 ]
机构
[1] Ist Italiano Tecnol IIT, Robot Brain & Cognit Sci, Genoa, Italy
[2] Ist Italiano Tecnol IIT, Ctr Neurosci & Cognit Syst UniTn, Genoa, Italy
[3] Univ Minnesota, Human Sensorimotor Control Lab, Ctr Clin Movement Sci, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Sch Kinesiol, Minneapolis, MN 55455 USA
关键词
joint position sense; proprioceptive acuity; wrist; robotic assessment; MOTOR COMMANDS; POSITION; ROLES;
D O I
暂无
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Neurological movement disorders such as stroke or sensory neuropathy are associated with somatosensory deficits. From a neurorehabilitation perspective, the assessment of proprioceptive function is important for planning and applying adequate rehabilitation treatments. Numerous behavioral and psychophysical methods arc available to measure proprioceptive acuity. However, no universally accepted and adopted protocol exists. In recent years robotic devices have increasingly been used to investigate and assess proprioceptive function, but few studies have focused on the wrist joint. To fill this knowledge gap, this study aimed to systematically map the proprioceptive acuity of the wrist for its two joint degrees of freedom (DoF) flexion/extension (FE) and abduction/adduction (AA). Twenty eight healthy young adults performed an ipsilateral, active joint position matching task using a robotic device. As a measure of proprioceptive acuity we determined the error between target position and the matched joint position. Results showed that: first, proprioceptive acuity varied between the two joint DoF with the matching error for AA being lower than the FE. Second, within each DoF, the motion direction did not affect the accuracy. Third, the radial component of the matching error showed DoF dependence: the FE movements tended to undershoot, while the AA movement overshot the target position. Results are indicative of a joint DoF dependent anisotropy of wrist proprioceptive acuity.
引用
收藏
页码:894 / 898
页数:5
相关论文
共 50 条
  • [1] Wrist joint proprioceptive acuity assessment using inertial and magnetic measurement systems
    Li, Lin
    Li, ShuWang
    Li, YanXia
    INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2019, 15 (04)
  • [2] The calcaneocuboid joint moves with three degrees of freedom
    Thomas M Greiner
    Kevin A Ball
    Journal of Foot and Ankle Research, 1 (Suppl 1)
  • [3] JOINT MODELS, DEGREES OF FREEDOM, AND ANATOMICAL MOTION MEASUREMENT
    KINZEL, GL
    GUTKOWSKI, LJ
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (01): : 55 - 62
  • [4] Freezing and freeing of degrees of freedom in joint action learning
    Hafkamp, Marijn S. J.
    Casanova, Remy
    Bootsma, Reinoud J.
    FRONTIERS IN PSYCHOLOGY, 2023, 14
  • [5] THE WRIST JOINT
    REFIOR, HJ
    KRODEL, A
    ORTHOPADE, 1986, 15 (04): : 313 - 317
  • [6] MINIMAL JOINT MOTION OPTIMIZATION OF MANIPULATORS WITH EXTRA DEGREES OF FREEDOM
    YAHSI, OS
    OZGOREN, K
    MECHANISM AND MACHINE THEORY, 1984, 19 (03) : 325 - 330
  • [7] Ankle rehabilitation device with two degrees of freedom and compliant joint
    , C-M Racu
    Doroftei, I.
    MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING (MODTECH2015), 2015, 95
  • [8] Dynamic CT technique for assessment of wrist joint instabilities
    Leng, Shuai
    Zhao, Kristin
    Qu, Mingliang
    An, Kai-Nan
    Berger, Richard
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 : S50 - S56
  • [9] The Best of Both Worlds: A Joint Modeling Approach for the Assessment of Change across Repeated Measurements
    Hsieh, Chueh-An
    von Eye, Alexander
    INTERNATIONAL JOURNAL OF PSYCHOLOGICAL RESEARCH, 2010, 3 (01): : 177 - 210
  • [10] Osteoarthritis of the Wrist STT Joint and Radiocarpal Joint
    Wollstein, Ronit
    Clavijo, Julio
    Gilula, Louis A.
    ARTHRITIS, 2012,