Using flow conditioners to improve flow meter performance and reduce piping costs

被引:0
|
作者
Feener, DM [1 ]
机构
[1] VORTAB Co, San Marcos, CA USA
关键词
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The process controls industry is required to measure flow more accurately to meet plant operation and cost accounting objectives. Recent studies have shown that the accuracy of many flow meter technologies are adversely affected by flow disturbances of up to forty diameters upstream of the flow meter mounting location. In addition, many flow meter installations are not designed with the flow meter manufacturer's recommended straight run of piping, because plant sizes are being reduced to save costs. This results in poor flow meter performance and unacceptable errors in flow meter accuracy. The opposing concerns of reducing plant size and improving flow meter accuracy is resolved by using flow conditioners to improve flow meter performance in non ideal piping installations. This improvement can be demonstrated through the use of flow visualization (a technique that visually demonstrates flow conditioner performance) and empirical testing of various flow meter technologies with flow conditioners.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [1] Flow conditioners reduce piping cost and improve flowmeter performance
    McQueen, D
    MEASUREMENTS & CONTROL, 1996, (177): : 114 - 117
  • [2] A comparative study of two flow conditioners and their efficacy to reduce asymmetric swirling flow effects on orifice meter performance
    Ouazzane, AK
    Barigou, M
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1999, 77 (A8): : 747 - 753
  • [4] Numerical simulation of flow conditioners used for flow meter calibration
    von Lavante, E.
    Pereira, G. Moniz
    Banaszak, U.
    Mickan, B.
    COMPUTATIONAL FLUID DYNAMICS 2004, PROCEEDINGS, 2006, : 863 - +
  • [5] USING OSCILLATORY FLOW TO IMPROVE PERFORMANCE
    MACKLEY, M
    CHEMICAL ENGINEER-LONDON, 1987, (433): : 18 - 20
  • [6] Process modifiers improve performance and reduce costs
    Markarian, Jennifer
    Plastics, Additives and Compounding, 2004, 6 (02) : 34 - 37
  • [7] Improve Membrane System Performance and Reduce Costs
    Freeman, Scott
    Opflow, 2019, 45 (12) : 10 - 14
  • [8] Cryopump pumping performance estimation using flow meter method
    Cheng, H. -P.
    Chen, T. -H.
    Lu, Y. -C.
    Sun, C. -W.
    IDMC 05: PROCEEDINGS OF THE INTERNATIONAL DISPLAY MANUFACTURING CONFERENCE 2005, 2005, : 668 - 672
  • [9] FLOW METER PERFORMANCE .2.
    BAUMOEL, J
    AUSTRALIAN JOURNAL OF INSTRUMENTATION & CONTROL, 1979, 35 (03): : 62 - 63
  • [10] Ultrasonic doppler flow meter performance
    Trimmer, W.L.
    Taylor, A.