Evaluation of hydraulic mixing performance in a full-scale anaerobic digester with an external liquid recirculation system using CFD and experimental validation
被引:7
|
作者:
Arnau, Rosario
论文数: 0引用数: 0
h-index: 0
机构:
Univ Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, SpainUniv Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, Spain
Arnau, Rosario
[1
]
Climent, Javier
论文数: 0引用数: 0
h-index: 0
机构:
Univ Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, SpainUniv Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, Spain
Climent, Javier
[1
]
Martinez-Cuenca, Raul
论文数: 0引用数: 0
h-index: 0
机构:
Univ Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, SpainUniv Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, Spain
Martinez-Cuenca, Raul
[1
]
Rodriguez, Jorge
论文数: 0引用数: 0
h-index: 0
机构:
Khalifa Univ, Res & Innovat Ctr CO2 & H2 RICH, Dept Chem Engn, POB 127788, Abu Dhabi, U Arab EmiratesUniv Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, Spain
Rodriguez, Jorge
[2
]
Chiva, Sergio
论文数: 0引用数: 0
h-index: 0
机构:
Univ Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, SpainUniv Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, Spain
Chiva, Sergio
[1
]
机构:
[1] Univ Jaume 1, Dept Mech Engn & Construct, Avd Vicent Sos Baynat S-N, Castellon de La Plana 12071, Spain
[2] Khalifa Univ, Res & Innovat Ctr CO2 & H2 RICH, Dept Chem Engn, POB 127788, Abu Dhabi, U Arab Emirates
Anaerobic digestion (AD) has become an essential process for sludge treatment and its optimum perfor-mance is related to its mixing degree. In this study, a full-scale Anaerobic Digester (ADer) with an exter-nal recirculation mixing system was studied via single-phase 3D-CFD simulations to assess the influence of recirculation flow and a 3-blade propeller. The model was validated with inert tracer tests. The design and mixing parameters were studied to characterise the mixing efficiency in different scenarios. The design parameters were assessed first, but wide deviations from the recommended values were found. Local mixing parameters were found to be useful for defining the degree and type of mixing, and are highly recommended in the CFD studies of ADers. A second-order statistical moment was proposed as a global mixing parameter to describe geometrical and local mixing, and to state a reliable homogenisa-tion time. (c) 2021 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
机构:
Univ Bradford, Fac Engn & Informat, Bradford BD7 1DP, W Yorkshire, EnglandUniv Bradford, Fac Engn & Informat, Bradford BD7 1DP, W Yorkshire, England
Dapelo, Davide
Bridgeman, John
论文数: 0引用数: 0
h-index: 0
机构:
Univ Bradford, Fac Engn & Informat, Bradford BD7 1DP, W Yorkshire, EnglandUniv Bradford, Fac Engn & Informat, Bradford BD7 1DP, W Yorkshire, England
机构:
Univ Wollongong, Sch Civil Min & Environm Engn, Strateg Water Infrastruct Lab, Wollongong, NSW 2500, AustraliaUniv Wollongong, Sch Civil Min & Environm Engn, Strateg Water Infrastruct Lab, Wollongong, NSW 2500, Australia
Nghiem, Long D.
Wickham, Richard
论文数: 0引用数: 0
h-index: 0
机构:
Univ Wollongong, Sch Civil Min & Environm Engn, Strateg Water Infrastruct Lab, Wollongong, NSW 2500, AustraliaUniv Wollongong, Sch Civil Min & Environm Engn, Strateg Water Infrastruct Lab, Wollongong, NSW 2500, Australia
Wickham, Richard
Ohandja, Dieudonne-Guy
论文数: 0引用数: 0
h-index: 0
机构:
Sydney Water, William Holmes St, Potts Hill, NSW 2143, AustraliaUniv Wollongong, Sch Civil Min & Environm Engn, Strateg Water Infrastruct Lab, Wollongong, NSW 2500, Australia