Effects of the Replacement Length of Concrete with ECC on the Cyclic Behavior of Reinforced Concrete Columns

被引:6
|
作者
Hyun, Jung-Hwan [1 ]
Bang, Jin-Wook [2 ]
Lee, Bang-Yeon [3 ]
Kim, Yun-Yong [4 ]
机构
[1] Ssangyong Engn & Construct Co Ltd, Civil Engn Team, 299 Olymp Ro, Seoul 05510, South Korea
[2] Tongyang Construct Mat Co Ltd, R&D Ctr, 2822 Gimpo Daero, Gimpo 10024, South Korea
[3] Chonnam Natl Univ, Sch Architecture, 77 Yongbong Ro, Gwangju 61186, South Korea
[4] Chungnam Natl Univ, Dept Civil Engn, 99 Daehak Ro, Daejeon 34134, South Korea
基金
新加坡国家研究基金会;
关键词
column; cyclic behavior; ductility; energy dissipation; ECC; DEFORMATION-BEHAVIOR; MATRIX DUCTILITY; STEADY-STATE; CRACKING; MEMBERS;
D O I
10.3390/ma14133542
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper presents an experimental investigation on the effects of the replacement length of concrete with engineered cementitious composites (ECC) on the cyclic behavior of a reinforced concrete (RC) column. A conventional RC column specimen and two RC composite columns designed with ECC were fabricated. To investigate the cyclic behavior of each specimen, a series of cyclic loading tests was performed under a reversed cyclic loading condition with a constant axial load. Test results showed that ECC columns exhibited higher cyclic behavior in terms of load carrying capacity, ductility, and energy dissipation capacity compared to the RC column. It was also found that when applying ECC to the column specimen with a length of 3.6d or more, the energy dissipation capacity was greatly increased.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Cyclic load behaviour of reinforced concrete columns with SMA and ECC in the critical regions
    George, Gisha
    Bindhu, K. R.
    Billah, A. H. M. Muntasir
    STRUCTURES, 2023, 58
  • [2] Cyclic behavior of concrete columns reinforced with partially unbonded hybrid
    Ibrahim, Adam I.
    Wu, Gang
    Sun, Zeyang
    Cui, Haoran
    ENGINEERING STRUCTURES, 2017, 131 : 311 - 323
  • [3] Compressive behavior of corroded reinforced concrete columns strengthened with BFRP reinforced ECC in marine environment
    Zhang, Zaiyu
    Wu, Xiaohong
    Sun, Qing
    Tian, Penggang
    Hu, Gaoxing
    OCEAN ENGINEERING, 2023, 279
  • [4] Effects of length and location of steel corrosion on the behavior and load capacity of reinforced concrete columns
    Xiao-Hui, Wang
    Xi-La, Liu
    Bao-Ru, Deng
    Journal of Shanghai Jiaotong University (Science), 2012, 17 (04) : 391 - 400
  • [5] Effects of Length and Location of Steel Corrosion on the Behavior and Load Capacity of Reinforced Concrete Columns
    王小惠
    刘西拉
    邓宝如
    Journal of Shanghai Jiaotong University(Science), 2012, 17 (04) : 391 - 400
  • [6] Seismic behavior of composite columns with steel reinforced ECC permanent formwork and infilled concrete
    Pan, Zuanfeng
    Zhu, Yazhi
    Qiao, Zhi
    Meng, Shaoping
    ENGINEERING STRUCTURES, 2020, 212
  • [7] Study on axial compression behavior of reinforced concrete columns strengthened by FRPG-ECC
    Li, Na
    Xia, Yongyang
    Li, Wangpeng
    Li, Shan
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2024, 52 (10): : 7 - 12
  • [8] Load history effect on cyclic behavior of reinforced concrete tied columns
    Lukkunaprasit, P
    Thepmangkorn, J
    JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (10) : 1629 - 1633
  • [9] Cyclic Behavior of Reinforced Concrete Columns with L-Shaped Ties
    Shin, Yeongsoo
    Kim, Hee-Sun
    Kim, Chul-Goo
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (03)
  • [10] Cyclic behavior of reinforced concrete columns with five-spiral reinforcement
    Ou, Yu-Chen
    Lau, John Victor Juvida
    Li, Jhe-Yan
    Havlasek, Petr
    Bittnar, Zdenek
    JOURNAL OF BUILDING ENGINEERING, 2022, 61