A proposed algorithm for diagnosing hypertension using automated office blood pressure measurement

被引:57
作者
Myers, Martin G. [1 ,2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Schulich Heart Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med, Div Cardiol, Toronto, ON, Canada
关键词
automated sphygmomanometers; blood pressure measurement; hypertension diagnosis; WHITE-COAT; RECOMMENDATIONS; VALIDATION;
D O I
10.1097/HJH.0b013e328335d091
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To validate an algorithm for the interpretation of automated office blood pressure (AOBP) measurement based upon data from untreated patients referred by physicians in the community for 24-h ambulatory blood pressure monitoring (ABPM). Methods An algorithm for interpreting AOBP readings was developed taking into account the previously documented equivalence of AOBP and mean awake ambulatory BP (ABP; mmHg), which were each classified as optimum BP (<130/80), borderline BP (130-139/80-89) and hypertension (>= 140/90). This classification was applied to data derived from 254 untreated patients undergoing 24-h ABPM, AOBP and routine manual BP taken at the patient's own family physician's office. Results The mean awake ABP (135.3+/-12.4/81.0+/-10.2) was similar to the mean AOBP (132.6+/-17.4/80.0+/-11.1) with both values being significantly (P<0.001) lower than the routine manual BP (149.7+/-15.2/89.3+/-9.5). Of the 69 patients with a systolic AOBP at least 140, only five (7.3%) exhibited white-coat hypertension with a normal mean awake ambulatory systolic BP less than 130. Similarly, of the 47 patients with a diastolic AOBP at least 90, none had optimum BP (diastolic BP<80 mmHg on ABPM). White-coat hypertension was significantly (P=0.005/P=0.006) more prevalent for systolic/diastolic BP (22.1%/13.4%) when routine, manual BP readings were analysed. Conclusion In contrast to routine manual office BP, a diagnosis of hypertension by AOBP is unlikely to be associated with an optimum awake ABP. J Hypertens 28: 703-708 (C) 2010 Wolters Kluwer Health | Lippincott Williams & Wilkins.
引用
收藏
页码:703 / 708
页数:6
相关论文
共 23 条
[1]   The BpTRU automatic blood pressure monitor compared to 24 hour ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension [J].
Beckett L. ;
Godwin M. .
BMC Cardiovascular Disorders, 5 (1)
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[4]   Daytime and nighttime blood pressure as predictors of death and cause-specific cardiovascular events in hypertension [J].
Fagard, Robert H. ;
Celis, Hilde ;
Thijs, Lutgarde ;
Staessen, Jan A. ;
Clement, Denis L. ;
De Buyzere, Marc L. ;
De Bacquer, Dirk A. .
HYPERTENSION, 2008, 51 (01) :55-61
[5]  
Hemmelgarn Brenda R, 2005, Can J Cardiol, V21, P645
[6]   Diagnostic thresholds for ambulatory blood pressure monitoring based on 10-year cardiovascular risk [J].
Kikuya, Masahiro ;
Hansen, Tine W. ;
Thijs, Lutgarde ;
Bjorklund-Bodegard, Kristina ;
Kuznetsova, Tatiana ;
Ohkubo, Takayoshi ;
Richart, Tom ;
Torp-Pedersen, Christian ;
Lind, Lars ;
Ibsen, Hans ;
Imai, Yutaka ;
Staessen, Jan A. .
CIRCULATION, 2007, 115 (16) :2145-2152
[7]  
Mancia G, 1995, J HYPERTENS, V13, P1377
[8]  
Myers Martin G, 2007, J Clin Hypertens (Greenwich), V9, P267
[9]   Consistent relationship between automated office blood pressure recorded in different settings [J].
Myers, Martin G. ;
Valdivieso, Miguel ;
Kiss, Alexander .
BLOOD PRESSURE MONITORING, 2009, 14 (03) :108-111
[10]   Use of automated office blood pressure measurement to reduce the white coat response [J].
Myers, Martin G. ;
Valdivieso, Miguel ;
Kiss, Alexander .
JOURNAL OF HYPERTENSION, 2009, 27 (02) :280-286