Plethysmography Variability Index and Stroke Volume Variation Changes in Relation to Central Venous Pressure Changes During Living Related Donor Right Hepatotomy: A Diagnostic Test Accuracy

被引:1
|
作者
Kamel, Yasmin Abdelsalam [1 ]
Ammar, Amany Said [2 ]
Baiomy, Omnai Gamal [1 ]
Lotfi, Mamdouh El-Sayed [2 ]
Yassen, Khaled Ahmed [1 ,3 ]
机构
[1] Menoufia Univ, Natl Liver Inst, Anesthesia Dept, Shebin El Kom City, Egypt
[2] Menoufia Univ, Fac Med, Anaesthesia Dept, Shebin El Kom City, Egypt
[3] King Faisal Univ, Coll Med, Anesthesia Div, Surg Dept, Al Hasa, Saudi Arabia
关键词
Fluid status; Liver donation surgery; Monitoring; PREDICT FLUID RESPONSIVENESS; MECHANICALLY VENTILATED PATIENTS; DYNAMIC PRELOAD VARIABLES; MINIMAL BLOOD-LOSS; LIVER-TRANSPLANTATION; HEPATIC RESECTION; ARTERIAL-PRESSURE; INTENSIVE-CARE; HEPATECTOMY; MANAGEMENT;
D O I
10.6002/ect.2020.0546
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Objectives: During donor hepatectomy, we investigated (1) the Electrical Cardiometry associations and agreements between noninvasive plethysmography variability index and noninvasive stroke volume variation, (2) their association with central venous pressure, and (3) their ability to monitor intraoperative changes and discriminate donors with increased blood loss. Materials and Methods: A diagnostic test accuracy was applied among donors (American Society of Anesthesiologists classification I). Data were recorded at 10 minutes after anesthesia induction, hourly during dissection, after resection, and at end of surgery. Crystalloids were restricted during resection to reduce central venous pressure but were otherwise infused to maintain mean invasive arterial blood pressure >60 mm Hg and urine output >0.5 mL/kg/h. Results: All 34 donors were related. Sons or daughters represented 58.8% (median age 26.0 years [interquartile range, 21.0-34.0]). Median values (with interquartile ranges) were anesthesia time, 7.5 hours (7.0-8.0); blood loss, 400 mL (400.0-500.0); infused acetated Ringer solution, 4000.0 mL (3500.0-4500.0); colloids, 250.0 mL (0-500.0); and urine output, 1.4 mL/kg/h (1.30-1.7). No blood products were transfused. Central venous pressure showed negligible negative correlations for both plethysmography variability index and stroke volume variation. Plethysmography variability index showed negligible correlation and poor agreement with stroke volume variation (P < .001, with intraclass correlation = 0.213 and a relatively wide bias; 95% CI, 0.03-0.37). All 3 methods reflected a state of normovolemia despite fluid restriction during resection and were unable to discriminate donors with increased blood loss (>400 mL). Conclusions: Plethysmography variability index and stroke volume variation showed negligible correlation and poor agreement with central venous pressure. Transfusion-free dissection was possible despite normovolemia, with median values of 8 mm Hg central venous pressure, 10% stroke volume variation, and 12% plethysmography variability index. Plethysmography variability index and stroke volume variation were unable to discriminate donors with increased blood loss.
引用
收藏
页码:693 / 702
页数:10
相关论文
共 5 条
  • [1] Stroke Volume Variation-Guided Versus Central Venous Pressure-Guided Low Central Venous Pressure With Milrinone During Living Donor Hepatectomy: A Randomized Double-Blinded Clinical Trial
    Lee, Jiwon
    Kim, Won Ho
    Ryu, Ho-Geol
    Lee, Hyung-Chul
    Chung, Eun-Jin
    Yang, Seong-Mi
    Jung, Chul-Woo
    ANESTHESIA AND ANALGESIA, 2017, 125 (02): : 423 - 430
  • [2] Assessment of fluid responsiveness using pulse pressure variation, stroke volume variation, plethysmographic variability index, central venous pressure, and inferior vena cava variation in patients undergoing mechanical ventilation: a systematic review and meta-analysis
    Chaves, Renato Carneiro de Freitas
    Barbas, Carmen Silvia Valente
    Queiroz, Veronica Neves Fialho
    Neto, Ary Serpa
    Deliberato, Rodrigo Octavio
    Pereira, Adriano Jose
    Timenetsky, Karina Tavares
    Silva Junior, Joao Manoel
    Takaoka, Flavio
    de Backer, Daniel
    Celi, Leo Anthony
    Correa, Thiago Domingos
    CRITICAL CARE, 2024, 28 (01)
  • [3] Observations on significant hemodynamic changes caused by a high concentration of epidurally administered ropivacaine: correlation and prediction study of stroke volume variation and central venous pressure in thoracic epidural anesthesia
    Jeong-Min Hong
    Hyeon Jeong Lee
    Young-Jae Oh
    Ah Rhem Cho
    Hyae Jin Kim
    Do-Won Lee
    Wang-Seok Do
    Jae-Young Kwon
    Haekyu Kim
    BMC Anesthesiology, 17
  • [4] Observations on significant hemodynamic changes caused by a high concentration of epidurally administered ropivacaine: correlation and prediction study of stroke volume variation and central venous pressure in thoracic epidural anesthesia
    Hong, Jeong-Min
    Lee, Hyeon Jeong
    Oh, Young-Jae
    Cho, Ah Rhem
    Kim, Hyae Jin
    Lee, Do-Won
    Do, Wang-Seok
    Kwon, Jae-Young
    Kim, Haekyu
    BMC ANESTHESIOLOGY, 2017, 17
  • [5] Relationship between pulse pressure variation and stroke volume variation with changes in cardiac index during hypotension in patients undergoing major spine surgeries in prone position - A prospective observational study
    Arumugam, Rajasekar
    Thomas, Susan
    Jacob, Nisha Sara M.
    Nadaraj, Ambily
    George, Sajan P.
    Singh, Georgene
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2022, 38 (04) : 553 - 559