Real-time myocardial contrast echocardiography for the detection of stress-induced myocardial ischemia

被引:2
|
作者
Dubart, AE
da Silva, KGC
Korosoglou, G
Bekeredjian, R
Hanson, A
Hardt, S
Rosenberg, M
Ferrari, N
Hoerig, B
Zehelein, J
Kuecherer, H
机构
[1] Dept Cardiol Innere Med III, D-69120 Heidelberg, Germany
[2] Univ Lille, Clin Invest Ctr, Lille, France
来源
ZEITSCHRIFT FUR KARDIOLOGIE | 2004年 / 93卷 / 11期
关键词
contrast echocardiography; myocardial perfusion; myocardial ischemia; coronary artery disease; perfusion imaging;
D O I
10.1007/s00392-004-0144-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Realtime contrast echocardiography (MCE) is a new promising technique for assessing myocardial perfusion. The purpose of this study was to test whether realtime MCE can be used to detect functionally significant coronary artery stenosis in patients with known or suspected coronary artery disease. Myocardial contrast echo cardiographic studies were compared with nearly simultaneous 99mTc-sestamibi single photon emission computed tomography (SPECT) as a clinical standard reference to evaluate regional myocardial perfusion defects. Methods Real-time MCE based on continuous infusion of Optison (8-10 ml/h) was performed in 66 patients during standard 99mTc-SPECT dipyrida-mole (0.56 mg/kg x 4 min) stress testing. Images were obtained in apical 4- and 2-chamber views, each divided into 6 segments. Tracer uptake and myocardial opacification were visually analyzed for each segment by two pairs of blinded observers and graded as normal, mildly reduced, severely reduced, or absent. In 792 myocardial segments, myocardial opacification by MCE was uninterpretable in 143 (18%) segments and tracer uptake by SPECT was not clearly defined in 92 (12%) segments. Interobserver variability for MCE was good with concordance rates of 83% (K = 0.72) for rest- and 86% (K = 0.76) for stress images. Overall concordance between MCE and SPECT was good (83%, K = 0.63) at a segmental level. In the diagnosis of fixed and reversible defects, and of normal perfusion, concordance rates were 73, 65 and 83%, respectively. When analysis was performed at the regional level, we found comparable levels of concordance rates for LAD (83%, K = 0.59), LCX (86%, K = 0.64) and RCA (80%, K = 0.68) perfusion territories. Conclusions These findings suggest that realtime MCE is a clinically acceptable method to evaluate myocardial perfusion defects during dipyridamole stress testing.
引用
收藏
页码:890 / +
页数:7
相关论文
共 50 条
  • [1] Feasibility and diagnostic accuracy of real-time myocardial contrast echocardiography in detecting stress-induced perfusion defects
    Dubart, E
    da Silva, KG
    Hansen, A
    Korosoglou, G
    Rosenberg, M
    Ferrari, N
    Zehelein, J
    Kücherer, H
    EUROPEAN HEART JOURNAL, 2002, 23 : 397 - 397
  • [2] Safety of dobutamine stress real-time myocardial contrast echocardiography
    Tsutsui, JM
    Elhendy, A
    Xie, F
    O'Leary, EL
    McGrain, AC
    Porter, TR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) : 1235 - 1242
  • [3] Quantification of transmural gradient of blood flow in myocardial ischemia with real-time myocardial contrast echocardiography and dipyridamole stress test
    Yao, Gui-Hua
    Zhang, Cheng
    Sun, Feng-Rong
    Zhang, Mei
    Zhao, Yu-Xia
    Zhang, Peng-Fei
    Zhong, Lin
    Ding, Shi-Fang
    Chen, Wen-Qiang
    Li, Xiao-Nan
    Zhang, Yun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (01): : 22 - 30
  • [4] Real-time myocardial contrast dobutamine stress echocardiography in coronary stenosis
    Roberts, Elved B.
    Schafer, Frank
    Akhtar, Wahid
    Patel, Devan
    Evans, Tom R.
    Coghlan, J. G.
    Lipkin, David P.
    Davar, Joseph I.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 113 (01) : 19 - 24
  • [5] REAL-TIME MYOCARDIAL CONTRAST STRESS ECHOCARDIOGRAPHY USING BOLUS APPLICATION
    Wasmeier, Gerald H.
    Asmussen, Sven
    Voigt, Jens-Uwe
    Flachskampf, Frank A.
    Daniel, Werner G.
    Nixdorff, Uwe
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (11): : 1724 - 1731
  • [7] Comparison of adenosine stress and dobutamine stress by real-time myocardial contrast echocardiography in detecting myocardium ischemia in dogs
    Xing Yan-qiu
    Hou Bo-wen
    Zhang Yun
    Liu Xiang-qun
    Gao Hai-qing
    CHINESE MEDICAL JOURNAL, 2009, 122 (17) : 2002 - 2007
  • [8] Global impaired myocardial perfusion in the setting of acute ischemia: A real-time myocardial contrast echocardiography assessment
    Khankirawatana, B
    Khankirawatana, S
    Lof, J
    Porter, TR
    CIRCULATION, 2001, 104 (17) : 469 - 469
  • [9] Detection of myocardial ischaemia using power modulation real-time contrast echocardiography during adenosine stress echocardiography
    Gudmundsson, P
    Winter, R
    Dencker, M
    Thorsson, O
    Willenheimer, R
    EUROPEAN HEART JOURNAL, 2004, 25 : 380 - 381
  • [10] Detection of Subendocardial Ischemia in the Left Anterior Descending Coronary Artery Territory With Real-Time Myocardial Contrast Echocardiography During Dobutamine Stress Echocardiography
    Xie, Feng
    Dodla, Saritha
    O'Leary, Edward
    Porter, Thomas R.
    JACC-CARDIOVASCULAR IMAGING, 2008, 1 (03) : 271 - 278