Evaluation of a new thermometer for rapid axillary temperature measurement in preterm infants

被引:0
|
作者
Dollberg, S [1 ]
Mincis, L [1 ]
Mimouni, FB [1 ]
Ashbel, G [1 ]
Barak, M [1 ]
机构
[1] Tel Aviv Med Ctr & Sch Med, Lis Matern Hosp, Dept Neonatol, IL-64239 Tel Aviv, Israel
关键词
thermometry; preterm infants; accurate; reproducible;
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Mercury-in-glass thermometers are considered the "gold-standard" for temperature measurements, but require at least 4 minutes for accuracy. Electronic thermometers sample temperature measurements over a shorter period. The objective of this study was to evaluate the accuracy and reproducibility of the Penguin (Medisim, Jerusalem, Israel) and the IVAC (San Diego, CA) Temp plus 11 thermometers in preterm infants. Axillary temperature was obtained in 50 thermally stable preterm. infants each time with the mercury-in-glass, the IVAC, and the Penguin thermometers. Analysis of variance F-test, and linear regression analyses were used to test correlation of each electronic thermometer with the mercury-in-glass one, and the effect of body weight. Temperature measurement taken with the Penguin thermometer was significantly higher than that measured with the two other ones, p < 0.001. The differences in means and in variances were not significantly different between IVAC and mercury-in-glass, while the variance of the Penguin measurement was higher than that of the two other instruments (P < 0.001). The IVAC instrument correlated more tightly with the mercury-in-glass (r = 0.89,p < 0.001) than did the Penguin (r = 0.54, P < 0.001). There was an inverse correlation between the deviation of the Penguin measurement from the mercury-in-glass and the weight of the patient (P < 0.08), while no significant correlation was found between the deviation of the IVAC measurement from the mercury in glass and the patient's weight (p = 0.56). Measurements of axillary temperature using the Penguin thermometer in incubated preterm infants are less accurate and less reproducible than those obtained using the IVAC or the glass thermometers.
引用
收藏
页码:201 / 204
页数:4
相关论文
共 50 条
  • [1] TAKING AN INFANTS TEMPERATURE - AXILLARY OR RECTAL THERMOMETER
    BROWN, PJ
    CHRISTMAS, BF
    FORD, RPK
    NEW ZEALAND MEDICAL JOURNAL, 1992, 105 (939) : 309 - 311
  • [2] Precision of a new thermometer for rapid rectal temperature measurement in neonates
    Dollberg, S
    Lahav, S
    Mimouni, FB
    AMERICAN JOURNAL OF PERINATOLOGY, 2001, 18 (02) : 103 - 105
  • [3] Precision of a new thermometer for rapid rectal temperature measurement in neonates
    Dollberg, S
    Lahav, S
    Mimouni, FB
    PEDIATRIC RESEARCH, 2000, 47 (04) : 396A - 396A
  • [4] Axillary versus rectal temperature measurement in premature and newborn infants
    Roll, C
    Wallot, M
    Hanssler, L
    ZEITSCHRIFT FUR GEBURTSHILFE UND NEONATOLOGIE, 1998, 202 (05): : 207 - 211
  • [5] Continuous measurement of core body temperature in preterm infants
    Dollberg, S
    Rimon, A
    Atherton, HD
    Hoath, SB
    AMERICAN JOURNAL OF PERINATOLOGY, 2000, 17 (05) : 257 - 264
  • [6] Comparing Axillary and Rectal Temperature Measurements in Very Preterm Infants: A Prospective Observational Study
    Cho, Mikyoung
    Kim, Chae Young
    Lee, JungBok
    Lee, Yumi
    Park, Minhwa
    Bae, Soohyun
    Kim, Yuri
    Kim, Yongjoo
    Lee, Byong Sop
    Kim, Ellen Ai-Rhan
    Kim, Ki-Soo
    Jung, Euiseok
    NEONATOLOGY, 2021, 118 (02) : 180 - 186
  • [7] Development of a new thermometer for the measurement of carcass surface temperature in slaughterhouse
    Duret, Steven
    Gahartian, Jerome
    Binti-Zacharia, Farah
    Thomas, Alain
    Derens-Bertheau, Evelyne
    26TH IIR INTERNATIONAL CONGRESS OF REFRIGERATION, VOL 3, 2023, : 199 - 207
  • [8] THERMOMETER FOR MEASURING RAPID TEMPERATURE CHANGES
    不详
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 1962, A 21 (10): : 494 - &
  • [9] An evaluation of a new human milk fortifier in preterm infants
    McNaught, TP
    Chan, GM
    Reis, B
    JOURNAL OF INVESTIGATIVE MEDICINE, 2000, 48 (01) : 93A - 93A
  • [10] Comparison of tympanic temperature readings with axillary thermometer in the OPD setting
    Malik, Munir
    Rabbani, Mohammad Zafar
    Amir, Mohammed
    Afzal, Uzma
    Malik, Mohammad Umair
    RAWAL MEDICAL JOURNAL, 2009, 34 (02):