Regenerative magnet load power supply with utility friendly operation

被引:0
|
作者
Balaji, AS [1 ]
Das, SP [1 ]
Dubey, GK [1 ]
Basu, M [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Kanpur 208016, Uttar Pradesh, India
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the present paper, a utility friendly regenerative magnet load power supply has been proposed which can tolerate supply voltage dips and long duration sags or under voltages and maintains unity input power factor under all operating conditions. The harmonies injected into the utility are very less and the total harmonic distortion (THD) complies with IEEE standards. Unity power factor at the input is maintained by using a synchronous link onverter (SLC) as the front-end ac to dc converter with regenerative capability. The two-quadrant chopper in the second stage operates in a constant frequency current control mode and takes care of the load current ripple. The performance evaluation of the magnet load power supply has been made using SABER simulator. A laboratory prototype has been fabricated and tested successfully. The real time control algorithm has been implemented using a PC with PCL-207 data acquisition card.
引用
收藏
页码:1392 / 1397
页数:6
相关论文
共 50 条
  • [1] Utility friendly magnet-load power supply
    Tripathi, RK
    Das, SP
    2005 IEEE 36TH POWER ELECTRONIC SPECIALISTS CONFERENCE (PESC), VOLS 1-3, 2005, : 333 - 339
  • [2] Feedforward current control of MRI magnet with power supply driven operation
    Kitada, S.
    Sakamoto, R.
    Shirai, Y.
    Yokoyama, S.
    14TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2019), 2020, 1559
  • [3] The operation results and study of KSTAR pulsed electric power network for superconducting magnet power supply
    Song, Inho
    Eom, Daeyoung
    Ahn, Hyunsik
    FUSION ENGINEERING AND DESIGN, 2019, 143 : 164 - 170
  • [4] A LOW RIPPLE POWER-SUPPLY FOR HIGH-CURRENT MAGNET LOAD
    LIANG, R
    DEWAN, SB
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (04) : 1006 - 1015
  • [5] Power Supply of Electricity Driven Vehicles and Its Integration with the Load Curves of the Supply Operation.
    Oehms, Klaus Joachim
    Busch, Heinz
    Elektrotechnische Zeitschrift Ausgabe A, 1973, 94 (11): : 706 - 711
  • [6] STABILIZED MAGNET POWER SUPPLY
    KALINKEV.IF
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (05): : 1275 - &
  • [7] Research on Short Circuit Operation Control Strategy of a Superconducting Magnet Power Supply for CRAFT
    Ronglin Huang
    Yinfeng Zhu
    Peng Fu
    Liansheng Huang
    Zhongma Wang
    Liuwei Xu
    Ge Gao
    Journal of Fusion Energy, 2021, 40
  • [8] Research on Short Circuit Operation Control Strategy of a Superconducting Magnet Power Supply for CRAFT
    Huang, Ronglin
    Zhu, Yinfeng
    Fu, Peng
    Huang, Liansheng
    Wang, Zhongma
    Xu, Liuwei
    Gao, Ge
    JOURNAL OF FUSION ENERGY, 2021, 40 (02)
  • [9] Design of control algorithm for accelerator magnet power supply with large time constant load
    Xu Wang
    Peng Liu
    FengLi Long
    WenTong Su
    Yao Gao
    XiaoLei Shi
    Tao Zeng
    GuanJian Wu
    Jian Cheng
    Radiation Detection Technology and Methods, 2020, 4 : 383 - 391
  • [10] Design of control algorithm for accelerator magnet power supply with large time constant load
    Wang, Xu
    Liu, Peng
    Long, FengLi
    Su, WenTong
    Gao, Yao
    Shi, XiaoLei
    Zeng, Tao
    Wu, GuanJian
    Cheng, Jian
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2020, 4 (03) : 383 - 391