No improvement in reducing outliers in coronal axis alignment with patient-specific instrumentation

被引:19
|
作者
Maus, Uwe [1 ]
Marques, Carlos J. [2 ]
Scheunemann, David [3 ]
Lampe, Frank [3 ]
Lazovic, Djordje [1 ]
Hommel, Hagen [4 ]
Vogel, Dennis [5 ]
Haunschild, Martin [6 ]
Pfitzner, Tilman [7 ]
机构
[1] Carl von Ossietzky Univ Oldenburg, Pius Hosp, Univ Hosp Orthoped Surg, Georgstr 12, D-26121 Oldenburg, Germany
[2] Schoen Klin Hamburg Eilbek, Dept Orthoped & Joint Replacement, Res Ctr, Dehnhaide 120, D-22081 Hamburg, Germany
[3] Schoen Klin Hamburg Eilbek, Dept Orthoped & Joint Replacement, Dehnhaide 120, D-22081 Hamburg, Germany
[4] Lehrkrankenhaus Med Hsch Brandenburg, Orthoped Clin, Krankenhaus Markisch Oderland, Sonnenburger Weg 3, D-16269 Wriezen, Germany
[5] St Remigius Krankenhaus Opladen, Klin Orthopadie & Unfallchirurg, St Remigius 26, D-51379 Leverkusen, Germany
[6] Katholisches Klinikum Koblenz Montabaur, Klin Allgemeine Orthopadie Endoprothet & Kinderor, Kardinal Krementz Str 1-5, D-56073 Koblenz Montabaur, Germany
[7] Charite Univ Med Berlin, Ctr Musculoskeletal Surg, Dept Orthoped, Charitepl, D-10117 Berlin, Germany
关键词
Total knee replacement; Patient-specific instrumentation; Mechanical leg alignment; Clinical outcomes; TOTAL KNEE ARTHROPLASTY; RANDOMIZED CONTROLLED-TRIAL; COMPUTER-ASSISTED SURGERY; CONVENTIONAL INSTRUMENTATION; CLINICAL-TRIAL; POSTOPERATIVE ALIGNMENT; MECHANICAL ALIGNMENT; COMPONENT ALIGNMENT; FOLLOW-UP; SURVIVAL;
D O I
10.1007/s00167-017-4741-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose and hypothesis Patient-specific instrumentation (PSI) uses 3D preoperative imaging to produce individualized cutting blocks specific to patients' anatomy and according to the preoperative plan with the aim to reduce the number of mechanical leg alignment (MLA) outliers, to improve implant positioning and to decrease surgery time. The primary purpose of this study was to investigate the efficacy of a specific PSI in comparison with standard instrumentation (SI) in reducing the number of MLA outliers. It was hypothesized that the number of MLA outliers would be significantly lower in the PSI group. Methods A multicenter randomized controlled trial was implemented. There were 59 patients in the PSI group and 66 in the SI group. The absolute number of outliers outside the +/- 3 degrees target neutral MLA was compared between the groups with a Chi-square test. As secondary outcomes, the Knee Society Score (KSS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were compared between the groups preoperatively and at 90-day follow-up. Results There were 15 (26.3%) MLA outliers in the PSI group and 8 (12.3%) in the SI group. The number of outliers was not independent from the group ((2)(X) (1) = 3.8, p = 0.04; Relative risk = 1.5). Preoperatively, there were no significant differences between the groups when comparing their KSS and KOOS sub-scores. At 90 days postoperatively, the patients in the SI group showed better KOOS-Quality of Life (KOSS-QOL) in comparison with the PSI group (p < 0.0001). Conclusion The use of PSI did not significantly reduce the number of MLA outliers in comparison with SI. There were no differences when comparing the achieved mean MLA of both groups.
引用
收藏
页码:2788 / 2796
页数:9
相关论文
共 50 条
  • [1] No improvement in reducing outliers in coronal axis alignment with patient-specific instrumentation
    Uwe Maus
    Carlos J. Marques
    David Scheunemann
    Frank Lampe
    Djordje Lazovic
    Hagen Hommel
    Dennis Vogel
    Martin Haunschild
    Tilman Pfitzner
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 2788 - 2796
  • [2] No Evidence of Superiority in Reducing Outliers of Component Alignment for Patient-specific Instrumentation for Total Knee Arthroplasty: a Systematic Review
    Zhang, Qing-meng
    Chen, Ji-ying
    Li, Heng
    Chai, Wei
    Ni, Ming
    Zhang, Zhen-dong
    Yang, Fan
    ORTHOPAEDIC SURGERY, 2015, 7 (01) : 19 - 25
  • [3] Patient-Specific Instrumentation in Total Knee Arthroplasty Provides No Improvement in Component Alignment
    Stronach, Benjamin M.
    Pelt, Christopher E.
    Erickson, Jill A.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1705 - 1708
  • [4] Patient-specific instrumentation does not improve tibial component coronal alignment for medial UKA compared to conventional instrumentation
    Kalache, Houssam
    Mueller, Jacobus H.
    Saffarini, Mo
    Gancel, Evrard
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2020, 7 (01)
  • [5] Patient-specific instrumentation does not improve tibial component coronal alignment for medial UKA compared to conventional instrumentation
    Houssam Kalache
    Jacobus H. Müller
    Mo Saffarini
    Evrard Gancel
    Journal of Experimental Orthopaedics, 7
  • [6] Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes
    Kazumasa Yamamura
    Yukihide Minoda
    Ryo Sugama
    Yoichi Ohta
    Suguru Nakamura
    Hideki Ueyama
    Hiroaki Nakamura
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 1560 - 1567
  • [7] Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes
    Yamamura, Kazumasa
    Minoda, Yukihide
    Sugama, Ryo
    Ohta, Yoichi
    Nakamura, Suguru
    Ueyama, Hideki
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (05) : 1560 - 1567
  • [8] Accuracy of a patient-specific instrumentation for coronal plane alignment of an anatomic alignment total knee arthroplasty system: A radiographic study
    Mueller, Konstantin
    Lerch, Solveig
    Sauer, Bernd
    Lerch, Matthias
    TECHNOLOGY AND HEALTH CARE, 2022, 30 (06) : 1397 - 1406
  • [9] Accuracy of Coronal Plane Mechanical Alignment in a Customized, Individually Made Total Knee Replacement with Patient-Specific Instrumentation
    Levengood, Gary A.
    Dupee, Jack
    JOURNAL OF KNEE SURGERY, 2018, 31 (08) : 792 - 796
  • [10] Rotational alignment in patient-specific instrumentation in TKA: MRI or CT?
    Silva, Alcindo
    Pinto, Elisabete
    Sampaio, Ricardo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) : 3648 - 3652