Effects of scatter in dual-source CT

被引:1
|
作者
Kyriakou, Y. [1 ]
Ertel, D. [1 ]
Krause, J. [1 ]
Kalender, W. [1 ]
机构
[1] Inst Med Phys, Erlangen, Germany
关键词
D O I
10.1118/1.2760409
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the magnitude and distribution of scatter for dual‐source CT (DSCT) and its impact on image quality. Materials and Methods: Apart from forward scatter which is given for all CT scanners, the measurements at a dual‐source system is also affected by cross scattered photons from the second tube‐detector system arranged at 90°. Simulations and measurements of homogenous phantoms of increasing diameter (100–400 mm) and of anthropomorphic phantoms were conducted for a DSCT scanner (SOMATOM Definition, Siemens Medical Solutions, Forchheim, Germany). The simulations of both forward and cross scatter were carried out using combined analytical and Monte Carlo simulation methods using a collimation of 19.2 mm for both tube‐detector systems. Measurements of cross scatter were performed by switching one tube off, still reading out the corresponding detector. Cross scatter was evaluated with respect to anthropomorphic and homogeneous phantoms for different imaging conditions such as different tube voltages, bow—tie filters. Dual‐energy scanning was included in the evaluations. Results: The forward scatter fraction increased with increasing diameter to 10% for a PMMA phantom of 400 mm diameter; for cross scatter, the mean intensity was lower or equivalent to forward scatter for small phantoms but was larger for increased phantom diameters. For large objects the ratio of cross scatter intensity to the sum of primary signal and forward scatter intensity reaches values higher than 100%. The outer dimensions of the object appear to be decisive for cross‐scatter whereas the influence of phantom inhomogeneity appears to be negligible. For dual energy — dual source scan modes the tube current setting for each tube should be adapted to achieve a minimization of cross scatter. Conclusion: The cross scatter magnitude is non‐negligible for a DSCT system and a compensation of its contribution is necessary for the assurance of high image quality. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2345 / 2345
页数:1
相关论文
共 50 条
  • [1] Intensity distribution and impact of scatter for dual-source CT
    Kyriakou, Yiannis
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (23): : 6969 - 6989
  • [2] Quantitative assessment of motion effects in dual-source dual-energy CT and dual-source photon-counting detector CT
    Ahmed, Zaki
    Rajendran, Kishore
    Gong, Hao
    McCollough, Cynthia
    Leng, Shuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [3] Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids
    Ren, Lei
    Chen, Yingxuan
    Zhang, You
    Giles, William
    Jin, Jianyue
    Yin, Fang-Fang
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (03) : 416 - 427
  • [4] Deep learning-based forward and cross-scatter correction in dual-source CT
    Erath, Julien
    Voth, Tim
    Maier, Joscha
    Fournie, Eric
    Petersilka, Martin
    Stierstorfer, Karl
    Kachelriess, Marc
    MEDICAL PHYSICS, 2021, 48 (09) : 4824 - 4842
  • [5] Reduced Cross Scatter in Dual-source Cone-Beam CT by Asynchronous Projection Acquisition
    Giles, W. M.
    Bowsher, J.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S681 - S681
  • [6] Scatter Correction Associated with Dedicated Dual-source CT Hardware Improves Accuracy of Lung Air Measures
    Mobberley, Sean D.
    Fuld, Matthew K.
    Sieren, Jered P.
    Primak, Andrew N.
    Hoffman, Eric A.
    ACADEMIC RADIOLOGY, 2013, 20 (11) : 1334 - 1343
  • [7] Thoracic applications of dual-source CT technology
    Boroto, Kahimano
    Remy-Jardin, Martine
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Pansini, Vittorio
    Tacelli, Nunzia
    Schmidt, Bernhard
    Gorgos, Andrei
    Remy, Jacques
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 375 - 384
  • [8] Dual-source CT in chest pain diagnosis
    Johnson, T. R. C.
    Nikolaou, K.
    Fink, C.
    Becker, A.
    Knez, A.
    Rist, C.
    Reiser, M. F.
    Becker, C. R.
    RADIOLOGE, 2007, 47 (04): : 301 - 309
  • [9] Dual-Source CT in Congenital Heart Disease
    Ruehm, S.
    Lohan, D.
    Krishnam, M.
    Panknin, C.
    Lell, M. M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [10] Noise Reduction in Dual-Source CT Scanning
    Petersilka, M.
    Krauss, B.
    Stierstorfer, K.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961