A dynamic nonlinear model for a once-through boiler-turbine unit in low load

被引:32
|
作者
Niu, Yuguang [1 ,3 ]
Du, Ming [1 ]
Ge, Weichun [2 ]
Luo, Huanhuan [2 ]
Zhou, Guiping [2 ]
机构
[1] North China Elect Power Univ, Sch Control & Comp Engn, Beijing 102206, Peoples R China
[2] State Grid Liaoning Elect Power Supply CO Ltd, Shenyang 110004, Liaoning, Peoples R China
[3] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
关键词
Nonlinear dynamic model; Once-through boiler; Low load; Nonlinear optimization algorithm; COORDINATED CONTROL; MATHEMATICAL-MODEL; CONTROLLER-DESIGN; CONTROL-SYSTEM; FUZZY MODEL; POWER-PLANT; VALIDATION; SIMULATION; ENERGY; EXERGY;
D O I
10.1016/j.applthermaleng.2019.113880
中图分类号
O414.1 [热力学];
学科分类号
摘要
Under the background of serious wind and solar energy curtailment in China, flexibility modification of coal-fired supercritical units is selected as an effective technical path to provide space for renewable energy into the grid. Modeling of coordinated control system in low load has yet to be conducted to date. In this work, a simplified dynamic model for coal-fired once-through boiler-turbine unit aimed at low load working condition is built up. First, the major model structure is established mainly based on mass and energy balance laws as well as thermodynamic equilibrium of important parameters combined with the analysis of operation characteristics. Then, the unknown parameters in the model are estimated by regression analysis, statistical analysis, and nonlinear optimization algorithm. Comparison results between measurement and simulation results show that the model has acceptable accuracy and, importantly, also captures the essential dynamic characteristics of units.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Analysis and Control of Once-through Boiler-Turbine Unit
    Huang Weijian
    Wu Yuzhong
    Kan Weimin
    Zhang Xi
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 678 - 681
  • [2] A dynamic hybrid model of supercritical once-through boiler-turbine unit including recirculation mode and once-through mode
    Xie, Yan
    Liu, Ji-zhen
    Zeng, De-liang
    Hu, Yong
    Li, Rui-lian
    Zhu, Yan-song
    ENERGY, 2024, 309
  • [3] A Dynamic Nonlinear Model of Once-Through Boiler-Turbine Units with Superheated Steam Temperature
    Fan, He
    Su, Zhi-gang
    Wang, Pei-hong
    Lee, Kwang Y.
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [4] A dynamic model used for controller design of a coal fired once-through boiler-turbine unit
    Liu, Ji-Zhen
    Yan, Shu
    Zeng, De-Liang
    Hu, Yong
    Lv, You
    ENERGY, 2015, 93 : 2069 - 2078
  • [5] A dynamic mathematical model used for controller design of a supercritical once-through boiler-turbine unit in all load conditions
    Xie, Yan
    Liu, Ji-zhen
    Zeng, De-liang
    Hu, Yong
    Zhu, Yan-song
    Li, Rui-lian
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [6] A dynamic mathematical model of an ultra-supercritical coal fired once-through boiler-turbine unit
    Fan, He
    Zhang, Yu-fei
    Su, Zhi-gang
    Wang, Ben
    APPLIED ENERGY, 2017, 189 : 654 - 666
  • [7] A dynamic nonlinear model for a wide-load range operation of ultra-supercritical once-through boiler-turbine units
    Fan, He
    Su, Zhi-gang
    Wang, Pei-hong
    Lee, Kwang Y.
    ENERGY, 2021, 226
  • [8] A dynamic model for supercritical once-through circulating fluidized bed boiler-turbine units
    Zhang, Hongfu
    Gao, Mingming
    Fan, Haohao
    Zhang, Kaiping
    Zhang, Jiahui
    ENERGY, 2022, 241
  • [9] A dynamic mathematical model for once-through boiler-turbine units with superheated steam temperature
    Fan, He
    Su, Zhi-gang
    Wang, Pei-hong
    Lee, Kwang Y.
    APPLIED THERMAL ENGINEERING, 2020, 170
  • [10] Affine nonlinear control for an ultra-supercritical coal fired once-through boiler-turbine unit
    Zhou, Hong
    Chen, Cheng
    Lai, Jingang
    Lu, Xiaoqing
    Deng, Qijun
    Gao, Xingran
    Lei, Zhongcheng
    ENERGY, 2018, 153 : 638 - 649