Auditing the image quality of mammograms

被引:2
|
作者
Young, KC [1 ]
King, S
Meeson, S
Ramsdale, ML
Cooke, J
Wallis, MG
机构
[1] Royal Surrey Cty Hosp, Dept Med Phys, Natl Coordinating Ctr Phys Mammog, Guildford GU2 7XX, Surrey, England
[2] Jarvis Breast Screening Ctr, Guildford GU1 1LJ, Surrey, England
[3] Coventry & Warwickshire Hosp, Warwickshire Solihull & Coventry Breast Screening, Coventry CV1 4FH, W Midlands, England
关键词
D O I
10.1093/oxfordjournals.rpd.a033138
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A quantitative approach to assessing the image quality of mammograms at screening centres has been developed. In this study an expert radiologist made a subjective judgement of the overall film blackening for each mammogram taken on a sequential series of 100 women attending screening over a period of three days on a single screening system. To relate these subjective judgements to quantitative measurements each mammogram was digitised and the distribution of film densities analysed. Average film densities in the main breast area were found to vary from 1.2 to 2.4, with an average of 1.8 for oblique views and 1.7 for CC views. The densities measured on quality control films of 40 mm thick PMMA exposed at 28 kV and 30 kV, and processed at the same time as the clinical films, were 1.52 and 1.67 respectively. Mammograms were judged satisfactory when film densities in the main breast region were in the range 0.8 to 2.8 with average densities of about 1.6 to 2.0. The method described allows the ideal film blackening to be quantitatively assessed.
引用
收藏
页码:279 / 282
页数:4
相关论文
共 50 条
  • [1] Image quality in lossy compressed digital mammograms
    Perlmutter, SM
    Cosman, PC
    Gray, RM
    Olshen, RA
    Ikeda, D
    Adams, CN
    Betts, BJ
    Williams, MB
    Perlmutter, KO
    Li, J
    Aiyer, A
    Fajardo, L
    Birdwell, R
    SIGNAL PROCESSING, 1997, 59 (02) : 189 - 210
  • [2] Denoising and Enhancing Image Quality for Detection Accuracy in Mammograms
    Hua, Yen Thi Hoang
    Nguyen, Giang Hong
    Nguyen, Linh Chi
    Van Liet, Dang
    IEEJ Transactions on Sensors and Micromachines, 2024, 144 (10) : 307 - 310
  • [3] Image quality in mammograms with low compressed breast thicknesses
    Loveland, J.
    Mackenzie, A.
    17TH INTERNATIONAL WORKSHOP ON BREAST IMAGING, IWBI 2024, 2024, 13174
  • [4] Evaluation of possible phantoms for assessment of image quality in synthetic mammograms
    Vancoillie, L.
    Cockmartin, L.
    Marshall, N. W.
    Lo, J. Y.
    Bosmans, H.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [5] Image quality of CRT displays and the effect of brightness on diagnosis of mammograms
    Hans Roehrig
    Elizabeth Krupinski
    Journal of Digital Imaging, 1998, 11 : 187 - 188
  • [6] Diagnostic Image Quality of Mammograms in German Outpatient Medical Care
    Pfandzelter, R.
    Wulfing, U.
    Boedeker, B.
    Kobrunner, S. Heywang
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (11): : 993 - 1000
  • [7] Image quality of CRT displays and the effect of brightness on diagnosis of mammograms
    Roehrig, H
    Krupinski, E
    JOURNAL OF DIGITAL IMAGING, 1998, 11 (03) : 187 - 188
  • [8] Auditing mammographic dose and image quality in the UK breast screening programme
    Young, KC
    Ramsdale, ML
    Rust, A
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 291 - 294
  • [9] PROBLEMS OF IMAGE QUALITY IN MAMMOGRAPHY - AVOIDABLE TECHNICAL ERRORS IN PERFORMANCE AND EVALUATION OF MAMMOGRAMS
    HUPPE, JR
    SCHNEIDER, HJ
    RADIOLOGE, 1977, 17 (05): : 197 - 202
  • [10] Comparison of image quality between mammograms performed by an assistant practitioner and by screening radiographers
    AE Tuson
    D Seddon
    CA Hopkins
    AJ Maxwell
    Breast Cancer Research, 4 (Suppl 1)