Coronary collateral blood-flow velocity improves with repeated coronary occlusions during angioplasty in patients with coronary artery disease and systemic hypertension

被引:1
|
作者
Kyriakides, ZS
Sbarouni, E
Paraskevaidis, IA
Giakoumakis, T
Tsiapras, D
Kremastinos, DT
机构
[1] Second Department of Cardiology, Onassis Cardiac Surgery Center, Athens
[2] Onassis Cardiac Surgery Center, Athens
关键词
coronary collateral blood flow; coronary angioplasty; systemic hypertension; coronary artery disease;
D O I
10.1097/00019501-199705000-00004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiac hypertrophy is associated with numerous alterations in the coronary circulation. Objective To test the hypothesis that, during angioplasty, the coronary collateral blood flow during repetitive coronary occlusions increases more in hypertensives than it does in normotensives. Methods We studied 34 patients (22 normotensives and 12 hypertensives) with stable angina and single-vessel disease undergoing coronary angioplasty during two similar balloon inflations. Each balloon inflation was maintained for 120 s. The coronary blood flow velocity was estimated using the Doppler-flow guide wire, which was positioned distally to the lesion. Flow velocities were recorded before balloon deflation. Results The average peak velocity increased by 29.0 +/- 14.7 mm/s in the hypertensives and decreased by 9.4 +/- 4.9 mm/s in the normotensives (P<0.01) during the second balloon inflation, whereas the velocity-time integral increased by 33.1 +/- 19.2 mm and decreased by 14.3 +/- 11.3 mm (P<0.05), respectively. The ST-segment elevation decreased by 1.13 +/- 1.27 and by 0.17 +/- 0.16 mV, respectively (P = 0.01). The increase in the average peak velocity which occurred during the second balloon inflation was related to the left ventricular mass (r = 0.47, P = 0.004). Conclusion These results indicate that the coronary collateral blood flow velocity improves with repetitive coronary occlusions during angioplasty in patients with systemic hypertension and that this increase is correlated to the left ventricular mass. (C) Rapid Science Publishers ISSN 0954-6928.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 50 条
  • [1] PHASIC CORONARY COLLATERAL FLOW VELOCITY IN CONSCIOUS DOGS WITH REPEATED CORONARY OCCLUSIONS
    MIKUNIYA, A
    ONODERA, K
    MCKOWN, DP
    MCKOWN, MD
    FRANKLIN, D
    CIRCULATION, 1990, 82 (04) : 380 - 380
  • [2] Acute endothelinA antagonism decreases coronary collateral blood flow in patients with coronary artery disease during angioplasty
    Kyriakides, ZS
    Kolettis, TM
    Sbarouni, E
    Antoniadis, A
    Psychari, S
    Kremastinos, DTH
    Webb, DJ
    EUROPEAN HEART JOURNAL, 2000, 21 : 513 - 513
  • [3] CHANGES IN CORONARY BLOOD-FLOW VELOCITY WITH SUCCESSFUL CORONARY ANGIOPLASTY
    SIBLEY, DH
    NATH, HP
    BULLE, TM
    DEAN, LS
    CHANDLER, JW
    WHITLOW, PL
    CLINICAL RESEARCH, 1986, 34 (01): : A175 - A175
  • [4] CORONARY COLLATERAL CIRCULATION IN CORONARY-ARTERY DISEASE AND SYSTEMIC HYPERTENSION
    KYRIAKIDES, ZS
    KREMASTINOS, DT
    MICHELAKAKIS, NA
    MATSAKAS, EP
    DEMOVELIS, T
    TOUTOUZAS, PK
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (08): : 687 - 690
  • [5] QUANTITATING CORONARY COLLATERAL FLOW VELOCITY IN PATIENTS DURING CORONARY ANGIOPLASTY USING A DOPPLER GUIDEWIRE
    KERN, MJ
    DONOHUE, TJ
    BACH, RG
    AGUIRRE, FV
    CARACCIOLO, EA
    OFILI, EO
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (14): : D34 - D40
  • [6] CORONARY COLLATERAL BLOOD-FLOW DURING ISCHEMIA
    RIEDY, M
    HAMRA, M
    STONE, HL
    FEDERATION PROCEEDINGS, 1985, 44 (03) : 822 - 822
  • [7] Coronary collateral blood flow recruitment is not decreased in diabetic patients: a study during coronary angioplasty
    Kyriakides, ZS
    Psychari, S
    Kolettis, TM
    Sbarouni, E
    Antoniadis, A
    Kremastinos, DTH
    EUROPEAN HEART JOURNAL, 2000, 21 : 630 - 630
  • [8] COMPARISON OF CHANGES IN CORONARY BLOOD-FLOW VELOCITY BEFORE AND AFTER CORONARY ANGIOPLASTY
    RAYMOND, RE
    TUZCU, M
    SHIREY, E
    GRIGERA, F
    HOLLMAN, J
    DOROSTI, K
    FRANCO, I
    WHITLOW, P
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 15 (03): : 203 - 203
  • [9] INTRACORONARY BLOOD-FLOW VELOCITY PROFILE IN PATIENTS WITH CORONARY-ARTERY DISEASE
    DIRSCHINGER, J
    DENNIG, K
    HALL, D
    RUDOLPH, W
    CIRCULATION, 1992, 86 (04) : 587 - 587
  • [10] EVALUATION OF RECRUITABLE COLLATERAL VESSELS BY CORONARY BLOOD-FLOW VELOCITY ANALYSIS IN THE IPSILATERAL AND CONTRALATERAL CORONARY-ARTERY
    PIEK, JJ
    VONLIEBERGEN, RA
    KOCH, KT
    PETERS, RJ
    DAVID, GK
    CIRCULATION, 1995, 92 (08) : 1252 - 1252