Collaborative ductile rupture mechanisms of high-purity copper identified by in situ X-ray computed tomography

被引:33
|
作者
Croom, Brendan P. [1 ]
Jin, Helena [2 ]
Noell, Philip J. [3 ]
Boyce, Brad L. [3 ]
Li, Xiaodong [1 ]
机构
[1] Univ Virginia, Dept Mech & Aerosp Engn, 122 Engineers Way, Charlottesville, VA 22904 USA
[2] Sandia Natl Labs, POB 969, Livermore, CA 94551 USA
[3] Sandia Natl Labs, POB 5800, Albuquerque, NM 87185 USA
基金
美国国家科学基金会;
关键词
Ductile fracture; Damage initiation; Void coalescence; Synchrotron radiation computed tomography; VOID GROWTH-MODELS; FRACTURE; COALESCENCE; DAMAGE; NUCLEATION; QUANTIFICATION; CRITERIA; FAILURE; METALS; ALLOY;
D O I
10.1016/j.actamat.2019.10.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The competition between ductile rupture mechanisms in high-purity Cu and other metals is sensitive to the material composition and loading conditions, and subtle changes in the metal purity can lead to failure either by void coalescence or Orowan Alternating Slip (OAS). In situ X-ray computed tomography tensile tests on 99.999% purity Cu wires have revealed that the rupture process involves a sequence of damage events including shear localization; growth of micron-sized voids; and coalescence of microvoids into a central cavity prior to the catastrophic enlargement of the coalesced void via OAS. This analysis has shown that failure occurs in a collaborative rather than strictly competitive manner. In particular, strain localization along the shear band enhanced void nucleation and drove the primary coalescence event, and the size of the resulting cavity and consumption of voids ensured a transition to the OAS mechanism rather than continued void coalescence. Additionally, the tomograms identified examples of void coalescence and OAS growth of individual voids at all stages of the failure process, suggesting that the transition between the different mechanisms was sensitive to local damage features, and could be swayed by collaboration with other damage mechanisms. The competition between the different damage mechanisms is discussed in context of the material composition, the local damage history, and collaboration between the mechanisms. (C) 2019 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:377 / 384
页数:8
相关论文
共 50 条
  • [1] Investigation of the slip geometry of high-purity potassium by in situ X-ray diffraction
    Krystian, M
    Pichl, W
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2004, 387 (1-2 SPEC. ISS.): : 115 - 120
  • [2] Trace analysis of high-purity copper by total reflection X-ray fluorescence spectrometry
    Yamaguchi, H
    Itoh, S
    Igarashi, S
    Naitoh, K
    Hasegawa, R
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (04): : 395 - 398
  • [3] Trace analysis of high-purity copper by total reflection X-ray fluorescence spectrometry
    Hitoshi Yamaguchi
    Sinji Itoh
    Shukuro Igarashi
    Kunishige Naitoh
    Ryosuke Hasegawa
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 395 - 398
  • [4] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [5] In situ observation of ductile fracture using X-ray tomography technique
    Toda, H.
    Maire, E.
    Yamauchi, S.
    Tsuruta, H.
    Hiramatsu, T.
    Kobayashi, M.
    ACTA MATERIALIA, 2011, 59 (05) : 1995 - 2008
  • [6] HIGH-PURITY GERMANIUM DETECTORS FOR X-RAY AND GAMMA-RAY SPECTROSCOPY
    GLASOW, P
    MULLER, A
    RAAB, G
    WOLF, HJ
    SIEMENS FORSCHUNGS-UND ENTWICKLUNGSBERICHTE-SIEMENS RESEARCH AND DEVELOPMENT REPORTS, 1978, 7 (04): : 181 - 188
  • [7] Investigation of ductile damage in dual phase steel during tensile deformation by in situ X-ray computed tomography
    Chen, Jiadong
    Magdysyuk, Oxana, V
    Li, Xiao
    Withers, Philip J.
    Yan, Kun
    ENGINEERING FRACTURE MECHANICS, 2023, 293
  • [8] Ductile fracture evaluated through micro-computed X-ray tomography
    Scheck, Caroline
    Zupan, Marc
    SCRIPTA MATERIALIA, 2011, 65 (12) : 1041 - 1044
  • [9] DETERMINATION OF IMPURITIES IN HIGH-PURITY LEAD BY X-RAY FLUORESCENT ANALYSIS
    MUNCHOW, P
    SCHRADER, HG
    METALL, 1977, 31 (09): : 987 - 990
  • [10] X-ray induced luminescence of high-purity, amorphous silicon dioxide
    Miller, AJ
    Leisure, RG
    Austin, WR
    JOURNAL OF APPLIED PHYSICS, 1999, 86 (04) : 2042 - 2050