This paper presents forced and ambient vibration tests on a six-storey precast concrete frame building, a structural system that has not often been the focus of such tests in spite of its widespread use. Precast buildings come with semi-rigid connections so their idealisation requires good knowledge of the construction practice for those connections and their details. Structural system dynamic properties are identified for the first three translational modes along each axis of the building and for the first three torsional modes. The study shows that the three-dimensional finite-element structural model for the building is capable of replicating the measured in situ dynamic properties. In the small displacement elastic range, the finite-element modelling of precast concrete frame systems is not very different from their cast-in-place counterparts but an extrapolation to the large displacement range requires empirical confirmation.
引用
收藏
页码:527 / 539
页数:13
相关论文
共 50 条
  • [1] Seismic design of a six-storey CLT building in Italy
    Vassallo, D.
    Follesa, M.
    Fragiacomo, M.
    ENGINEERING STRUCTURES, 2018, 175 : 322 - 338
  • [2] SOUND INSULATION IN A SIX-STOREY VOLUME BASED TIMBER BUILDING EQUIPPED WITH ELASTIC LAYERS
    Ljunggren, Fredrik
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, 2010,
  • [3] Dynamic testing and stiffness evaluation of a six-storey timber framed building during construction
    Ellis, BR
    Bougard, AJ
    ENGINEERING STRUCTURES, 2001, 23 (10) : 1232 - 1242
  • [4] Precast concrete frame construction for multi-storey car parks
    Rhodes, G.
    2001, Concrete Society (35):
  • [5] Effect of Beam-Column Connection Fixity on Collapse Performance of a Six-Storey Special Concentrically Braced Frame
    Mohsenzadeh V.
    Wiebe L.
    Key Engineering Materials, 2018, 763 KEM : 157 - 164
  • [6] Seismic performance assessment of two-storey precast reinforced concrete building
    Chourasia, Ajay
    Kajale, Yogesh
    Singhal, Shubham
    Parashar, Jalaj
    STRUCTURAL CONCRETE, 2020, 21 (05) : 2011 - 2027
  • [7] Precast reinforced concrete demountable system of multi-storey buildings
    Witzany, J.
    Zigler, R.
    Polak, A.
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 1300 - 1305
  • [8] Evaluation of the impact of compliance of precast discs of overlapping on the work of the frame of a multi-storey building
    Trekin, Nikolay
    Kodysh, Emil
    Bybka, Alexander
    Yamalov, Alexander
    Konkov, Nikita
    XXII INTERNATIONAL SCIENTIFIC CONFERENCE: CONSTRUCTION THE FORMATION OF LIVING ENVIRONMENT (FORM-2019), 2019, 97
  • [9] Probabilistic Risk Assessment of Life Safety for a Six-Storey Commercial Building with an Open Stair Interconnecting Four Storeys: A Case Study
    Prakash Sabapathy
    Aidan Depetro
    Khalid Moinuddin
    Fire Technology, 2019, 55 : 1405 - 1445
  • [10] Seismic behavior of a six-story precast concrete office building
    Low, SG
    Tadros, MK
    Einea, A
    Magana, RA
    PCI JOURNAL, 1996, 41 (06): : 56 - &