Regimes of jetting and bubbling in a fluidized bed studied using real-time magnetic resonance imaging

被引:21
|
作者
Penn, A. [1 ,2 ,3 ]
Boyce, C. M. [4 ]
Pruessmann, K. P. [1 ,2 ]
Mueller, C. R. [3 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomed Engn, Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] Swiss Fed Inst Technol, Dept Mech & Proc Engn, Zurich, Switzerland
[4] Columbia Univ, Dept Chem Engn, New York, NY 10027 USA
基金
瑞士国家科学基金会;
关键词
Fluidized bed reactors; Magnetic resonance imaging; Bubbling; Jetting; Jet length; Bubble breakoff frequency; JET PENETRATION DEPTH; GAS JETS; HYDRODYNAMICS; FLOW; SIMULATION; HEIGHT;
D O I
10.1016/j.cej.2019.123185
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Real-time magnetic resonance imaging was used to study the different flow regimes which occur in a fluidized bed containing a gas injection system. The gas flow rates through the main distributor and a central orifice were varied independently. We identified six different regimes of bubbling and jetting behavior: (1) freely bubbling, (2) permanent jet, (3) spouting, (4) pulsating jet, (5) pulsating jet with bubble collapse and (6) pulsating jet and freely bubbling. While regimes (1-4) have been described previously in the literature, regimes (5) and (6) are described here for the first time. To construct a regime map, the Froude number (Fr) and the ratio of the superficial gas velocity to the minimum fluidization velocity (U/U-mf) were used to describe the system. We observed that bubbles formed predominantly, when U/U-mf > 1. Further, we propose an empirical model that predicts the length of jets in the permanent jet regime as a function of Fr and background gas flow as l(jet)/d(or) = 0.12 Fr-0.38(1 + U-bg/U-mf)(0.81) The proposed model is in good agreement with tomographic measurements in smaller 3D systems reported in the literature, indicating that the non-dimensionalized description of jet length using a Fr number is valid throughout a large range of system diameters. Moreover, the bubble breakoff frequency of the pulsating jet regime was assessed by Fourier analysis, demonstrating that the frequency increases with increasing Fr before plateauing.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Eulerian simulations of bubbling and jetting regimes in a fluidized bed
    Parvathaneni, Sirisha
    Karmakar, Sujay
    Buwa, Vivek V.
    PARTICUOLOGY, 2023, 75 : 50 - 68
  • [2] The effect of baffles on the hydrodynamics of a gas-solid fluidized bed studied using real-time magnetic resonance imaging
    Rennebaum, Hannah S.
    Brummerloh, Daniel L.
    Benders, Stefan
    Penn, Alexander
    POWDER TECHNOLOGY, 2024, 432
  • [3] Real-time measurement of bubbling phenomena in a three-dimensional gas-fluidized bed using ultrafast magnetic resonance imaging
    Müller, CR
    Davidson, JF
    Dennis, JS
    Fennell, PS
    Gladden, LF
    Hayhurst, AN
    Mantle, MD
    Rees, AC
    Sederman, AJ
    PHYSICAL REVIEW LETTERS, 2006, 96 (15)
  • [4] Real-time magnetic resonance imaging of fluidized beds with internals
    Penn, Alexander
    Boyce, Christopher M.
    Conzelmann, Nicholas
    Bezinge, Gaetan
    Pruessmann, Klaas P.
    Muller, Christoph R.
    CHEMICAL ENGINEERING SCIENCE, 2019, 198 : 117 - 123
  • [5] Real-Time Magnetic Resonance Imaging
    Nayak, Krishna S.
    Lim, Yongwan
    Campbell-Washburn, Adrienne E.
    Steeden, Jennifer
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 81 - 99
  • [6] Real-Time Magnetic Resonance Imaging of Bubble Behavior and Particle Velocity in Fluidized Beds
    Penn, Alexander
    Boyce, Christopher M.
    Kovar, Thomas
    Tsuji, Takuya
    Pruessmann, Klaas P.
    Muller, Christoph R.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (29) : 9674 - 9682
  • [7] Tablet Disintegration Studied by High-Resolution Real-Time Magnetic Resonance Imaging
    Quodbach, Julian
    Moussavi, Amir
    Tammer, Roland
    Frahm, Jens
    Kleinebudde, Peter
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 103 (01) : 249 - 255
  • [8] Nomenclature for real-time magnetic resonance imaging
    Dietz, Bryson
    Fallone, B. Gino
    Wachowicz, Keith
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1483 - 1484
  • [9] Real-time functional magnetic resonance imaging
    Cohen, MS
    METHODS, 2001, 25 (02) : 201 - 220
  • [10] Vocal tract morphology using real-time magnetic resonance imaging
    Sampaio, Rafael de A.
    Jackowski, Marcel P.
    2017 30TH SIBGRAPI CONFERENCE ON GRAPHICS, PATTERNS AND IMAGES (SIBGRAPI), 2017, : 359 - 366