On-line sample pre-treatment systems interfaced to electrothermal atomic absorption spectrometry

被引:25
|
作者
Burguera, JL [1 ]
Burguera, M [1 ]
机构
[1] Univ Los Andes, Fac Sci, Andean Inst Chem Res, IVAIQUIM, Merida 5101A, Venezuela
关键词
flow injection; electrothermal atomic absorption spectrometry; interface; on-line sample pre-treatment;
D O I
10.1039/a708112j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Atomic spectrometric techniques working with a continuous supply of sample, such as flame atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry, are well suited for on-line connection through flow injection arrangements. For the determination of elements at lower concentrations, electrothermal atomization is often needed owing to the requirement for better detection limits, However, connecting a batch technique such as electrothermal atomic absorption spectrometry to a continuous flow or a flow injection system presents some fundamental difficulties, making it a real challenge for the analytical chemist to design suitable interfaces, There are different ways of interfacing the systems to each other; the available versions utilize either on-line sample treatment with off-line measurement or are completely on-line arrangements. Complex samples cannot be directly processed by this technique owing to severe matrix interferences, which have not been minimized despite the development of efficient background correction devices. Successful matrix separation can be achieved on-line through solvent and sorbent extraction, precipitation and coprecipitation, volatile compound generation and liquid chromatography. Moreover, transformation of the sample and/or its fractions into a form that can be analyzed in a graphite furnace often requires unpleasant, tedious and time-consuming digestion procedures. Microwave heating has emerged as a means of dramatically improving leaching, mineralization or digestion processes and has frequently been used with in-batch or on-line systems, This paper outlines the most recent advances in the development of flow injection-graphite furnace interfaces and also describes the on-line sample pre-treatment systems developed so far for electrothermal atomic absorption detection.
引用
收藏
页码:561 / 569
页数:9
相关论文
共 50 条
  • [1] Flow injection on-line electrothermal atomic absorption spectrometry
    Alonso, EV
    de Torres, AG
    Pavón, JMC
    TALANTA, 2001, 55 (02) : 219 - 232
  • [2] Flow injection on-line pre-concentration of platinum coupled with electrothermal atomic absorption spectrometry
    Limbeck, Andreas
    Rudolph, Elisabeth
    Hann, Stephan
    Koellensperger, Gunda
    Stingeder, Gerhard
    Rendl, Josef
    1600, Royal Society of Chemistry (19):
  • [3] Flow injection on-line pre-concentration of platinum coupled with electrothermal atomic absorption spectrometry
    Limbeck, A
    Rudolph, E
    Hann, S
    Koellensperger, G
    Stingeder, G
    Rendl, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (11) : 1474 - 1478
  • [4] On-line electrothermal atomic absorption spectrometry configurations: recent developments and trends
    Burguera, Marcela
    Burguera, Jose Luis
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) : 884 - 896
  • [5] Application of flow injection on-line electrothermal atomic absorption spectrometry to the determination of rhodium
    Rojas, FS
    Ojeda, CB
    Pavón, JMC
    ANNALI DI CHIMICA, 2005, 95 (06) : 437 - 445
  • [6] Sample pre-treatment methods for the trace elements determination in seafood products by atomic absorption spectrometry
    Bermejo-Barrera, P
    Moreda-Piñeiro, A
    Bermejo-Barrera, A
    TALANTA, 2002, 57 (05) : 969 - 984
  • [7] On-line microwave-assisted sample decomposition for lead determination in fish slurry samples by electrothermal atomic absorption spectrometry
    Arruda, MAZ
    Fostier, AH
    Krug, FJ
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 1997, 8 (01) : 39 - 45
  • [8] A time-based flow injection cold vapor atomic absorption spectrometry system with on-line microwave sample pre-treatment for the determination of inorganic and total mercury in urine
    Gallignani, M
    Bahsas, H
    Brunetto, MR
    Burguera, M
    Burguera, JL
    de Peña, YP
    ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) : 57 - 67
  • [9] Automatic on-line column preconcentration system for determination of cadmium by electrothermal atomic absorption spectrometry
    Alonso, EIV
    Gil, LP
    Cordero, MTS
    de Torres, AG
    Pavón, JMC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) : 293 - 295
  • [10] Indirect determination of nitrate by electrothermal atomic absorption spectrometry using an on-line cadmium microcolumn
    Alonso, EV
    Cordero, MTS
    Torres, MPC
    de Torres, AG
    Pavón, JMC
    ANALYST, 1998, 123 (07) : 1561 - 1564