An efficient procedure for tomotherapy treatment plan verification using the on-board detector

被引:8
|
作者
Pisaturo, O. [1 ]
Mieville, F. [1 ]
Tercier, P-A [1 ]
Allal, A. S. [1 ]
机构
[1] HFR Hop Fribourgeois, Dept Radiat Oncol, Fribourg, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 04期
关键词
tomotherapy; treatment plan verification; dose calculation model; DELIVERY VERIFICATION; HELICAL TOMOTHERAPY; DOSE VERIFICATION; IMRT; FILM;
D O I
10.1088/0031-9155/60/4/1625
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, a fast and simple procedure for tomotherapy treatment plan verification using the on-board detector (OBD) has been developed. This procedure allows verification of plans with static and dynamic jaws (TomoEDGE). A convolution-based calculation model has been derived in order to link the leaf control sinogram from the treatment planning system to the data acquired by the OBD during a static couch procedure. The convolution kernel has been optimized using simple plans calculated in the Tomotherapy Cheese phantom. The optimal kernel has been found to be a lorentzian function, whose parameter Gamma is 0.186 for the 1 cm jaw opening, 0.232 for the 2.5 cm jaw opening and 0.373 for the 5 cm jaw opening. The evaluation has been performed with gamma-index analysis. The dose criterion was 3% of the 95th percentile of the dose distribution and the distance-to-agreement criterion is 2 mm. In order to validate the procedure, it has been applied to around 50 clinical treatment plans, which had already been validated by the Delta4 phantom (Scandidos, Sweden). 96% of the tested plans have passed the criteria. Concerning the other 4%, significant discrepancies between the leaf pattern in the leaf control sinogram and the OBD data have been shown, which might be due to differences in the leaf open time. This corresponds also to a higher sensitivity of this method over the Delta4, adding the possibility of better monitoring the treatment delivery.
引用
收藏
页码:1625 / 1639
页数:15
相关论文
共 50 条
  • [1] An efficient procedure for treatment plan verification using the tomotherapy on-board detector
    Pisaturo, O.
    Mieville, F.
    Tercier, P. A.
    Allal, A. S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (01) : 88 - 88
  • [2] Detection of dose delivery variations on TomoTherapy using on-board detector based verification
    Hui, Cheukkai
    Chen, Quan
    Khandelwal, Shiv
    Neal, Brian
    Watkins, William
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (14):
  • [3] Treatment plan preparation and verification for total body irradiation using tomotherapy
    Konstanty, E.
    Malicki, J.
    Skrzypczak, K.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S722 - S722
  • [4] A Simulation Study of Treatment Verification Using On-Board Multipinhole SPECT
    Yan, S.
    Bowsher, J.
    Giles, W.
    Ren, L.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S707 - S707
  • [5] Transmission Verification Using the On-Board EPID
    Jin, P.
    Munbodh, R.
    Zhu, T.
    Lin, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [6] IMRT Verification Using the On-Board EPID
    Dormer, J.
    Witztum, A.
    Ding, X.
    Jin, P.
    Zhu, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 335 - 335
  • [7] A quality assurance tool for helical tomotherapy using a step-wedge phantom and the on-board MVCT detector
    Althof, Vincent
    van Haaren, Paul
    Westendorp, Rik
    Nuver, Tonnis
    Kramer, Dinant
    Ikink, Marijke
    Bel, Arjen
    Minken, Andre
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (01): : 148 - 163
  • [8] In air and in vivo measurement of the leaf open time in tomotherapy using the on-board detector pulse-by-pulse data
    Schopfer, Mathieu
    Bochud, Francois O.
    Bourhis, Jean
    Moeckeli, Raphael
    MEDICAL PHYSICS, 2019, 46 (05) : 1963 - 1971
  • [9] TomoTherapy MLC verification using exit detector data
    Chen, Quan
    Westerly, David
    Fang, Zhenyu
    Sheng, Ke
    Chen, Yu
    MEDICAL PHYSICS, 2012, 39 (01) : 143 - 152
  • [10] On-board imager-based MammoSite treatment verification
    Wojcicka, Jadwiga
    Yankelevich, Rafael
    Iorio, Stephen
    Tinger, Alfred
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (11) : 1065 - 1069