The internal standard methods are known to compensate for the errors from sample preparation and injection into an analytical instrument. However, recent HPLC apparatuses have injectors of excellent repeatability and it is dubious whether the cancellation of injection error can lead to substantial improvement in the precision of analysis. This paper answers the above question experimentally and theoretically. The HPLC analysis of butylscopolamine bromide is taken as an example. The relative standard deviations (RSD) of measurements in the internal standard method and absolute calibration curve method are compared and the advantages of these methods are discussed. The measurement RSD is shown to be well estimated by the (function of mutual information) (FUMI) theory without repeating measurements. This report also demonstrates simple equations for calculating the measurement RSD at an arbitrary concentration of analyte and for selecting the better method between the internal standard method and absolute calibration curve method under specific experimental conditions.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
  • [1] INTERNAL STANDARD HPLC METHOD FOR THE ANALYSIS OF PROPOXUR
    KIKTA, EJ
    HERBST, RM
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1979, 2 (04): : 599 - 606
  • [2] EFFECT OF THE AMOUNT OF INTERNAL STANDARD ON THE PRECISION OF AN ANALYTICAL METHOD
    JEMAL, M
    BERGUM, J
    JOURNAL OF CLINICAL PHARMACOLOGY, 1992, 32 (07): : 676 - 677
  • [3] Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS
    Joo, Mingyu
    Park, Myungsun
    Pak, Yong-Nam
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2014, 27 (03): : 140 - 146
  • [4] HIGH PRECISION ACTIVATION ANALYSIS OF SODIUM WITH AN INTERNAL STANDARD TECHNIQUE
    MARSH, RH
    ALLIE, W
    ANALYTICAL CHEMISTRY, 1968, 40 (13) : 2037 - &
  • [5] INTERNAL STANDARD HPLC METHOD FOR THE ANALYSIS OF AZINPHOS-METHYL USING A BONDED AMINE STATIONARY PHASE
    KIKTA, EJ
    HERBST, RM
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1979, 2 (04): : 589 - 598
  • [6] Analysis of uranium in environmental sample by internal standard method
    Han, Jun
    Fu, Zhong-Hua
    Jia, Bao-Ting
    Liu, Xue-Mei
    Mao, Xin-Gen
    Meng, Fan-Ben
    He-Huaxue yu Fangshe Huaxue/Journal of Nuclear and Radiochemistry, 2004, 26 (04):
  • [7] Determination of the Fluroxypyr Ester by HPLC with Internal Standard
    Zhu, Hua-Jing
    Chen, Ze-Li
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MATERIAL SCIENCE AND APPLICATIONS (ICMSA 2015), 2015, 3 : 760 - 764
  • [8] ELECTROIMMUNOASSAY PRECISION IMPROVED BY USING AN INTERNAL STANDARD
    LORIER, MA
    HAWES, C
    CLINICAL CHEMISTRY, 1985, 31 (04) : 647 - 647
  • [9] Tocopherol and tocotrienol analysis by NF-HPLC using an internal standard.
    Brindle, LK
    Craft, NE
    Li, Y
    FASEB JOURNAL, 2000, 14 (04): : A40 - A40
  • [10] An automated workflow approach for the analysis of flavin adenine dinucleotide by HPLC with internal standard
    Van Long Nguyen
    Ah-Loo, Andrew
    Fitzpatrick, Michael
    ANALYTICAL BIOCHEMISTRY, 2020, 594