Dynamic PET simulator via tomographic emission projection for kinetic modeling and parametric image studies

被引:14
|
作者
Haggstrom, Ida [1 ,2 ]
Beattie, Bradley J. [1 ]
Schmidtlein, C. Ross [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[2] Umea Univ, Dept Radiat Sci, S-90187 Umea, Sweden
关键词
dynamic PET; simulation; PETSTEP; Monte Carlo; compartment modeling; parametric imaging; NOISE PROPERTIES; CLINICAL PET; CANCER; SEGMENTATION; VALIDATION; THERAPY; PHANTOM; TUMORS; GATE; FDG;
D O I
10.1118/1.4950883
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and evaluate a fast and simple tool called dPETSTEP (Dynamic PET Simulator of Tracers via Emission Projection), for dynamic PET simulations as an alternative to Monte Carlo (MC), useful for educational purposes and evaluation of the effects of the clinical environment, postprocessing choices, etc., on dynamic and parametric images. Methods: The tool was developed in MATLAB using both new and previously reported modules of PETSTEP (PET Simulator of Tracers via Emission Projection). Time activity curves are generated for each voxel of the input parametric image, whereby effects of imaging system blurring, counting noise, scatters, randoms, and attenuation are simulated for each frame. Each frame is then reconstructed into images according to the user specified method, settings, and corrections. Reconstructed images were compared to MC data, and simple Gaussian noised time activity curves (GAUSS). Results: dPETSTEP was 8000 times faster than MC. Dynamic images from dPETSTEP had a root mean square error that was within 4% on average of that of MC images, whereas the GAUSS images were within 11%. The average bias in dPETSTEP and MC images was the same, while GAUSS differed by 3% points. Noise profiles in dPETSTEP images conformed well to MC images, confirmed visually by scatter plot histograms, and statistically by tumor region of interest histogram comparisons that showed no significant differences (p < 0.01). Compared to GAUSS, dPETSTEP images and noise properties agreed better with MC. Conclusions: The authors have developed a fast and easy one-stop solution for simulations of dynamic PET and parametric images, and demonstrated that it generates both images and subsequent parametric images with very similar noise properties to those of MC images, in a fraction of the time. They believe dPETSTEP to be very useful for generating fast, simple, and realistic results, however since it uses simple scatter and random models it may not be suitable for studies investigating these phenomena. dPETSTEP can be downloaded free of cost from https:// github. com/CRossSchmidtlein/dPETSTEP. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:3104 / 3116
页数:13
相关论文
共 50 条
  • [1] A fast dynamic PET simulator for improved kinetic modeling estimation
    Haggstrom, Ida
    Beattie, Bradley
    Humm, John
    Schmidtlein, Charles
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [2] PPET: A software tool for kinetic and parametric analyses of dynamic PET studies
    Boellaard, Ronald
    Yaqub, M.
    Lubberink, M.
    Lammertsma, A.
    NEUROIMAGE, 2006, 31 : T62 - T62
  • [3] POSITRON EMISSION TOMOGRAPHIC (PET) STUDIES IN DEMENTIA
    GOTO, I
    TANIWAKI, T
    HOSOKAWA, S
    OTSUKA, M
    ICHIYA, Y
    ICHIMIYA, A
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 1993, 114 (01) : 1 - 6
  • [4] DYNAMIC CEREBRAL POSITRON EMISSION TOMOGRAPHIC STUDIES
    TERPOGOSSIAN, MM
    FICKE, DC
    MINTUN, MA
    HERSCOVITCH, P
    FOX, PT
    RAICHLE, ME
    ANNALS OF NEUROLOGY, 1984, 15 : S46 - S47
  • [5] Direct Estimation of Kinetic Parametric Images for Dynamic PET
    Wang, Guobao
    Qi, Jinyi
    THERANOSTICS, 2013, 3 (10): : 802 - 815
  • [6] Using kinetic parameters analysis of dynamic PET studies for liver image segmentation
    Lin, HD
    Wu, LC
    Liu, RS
    Chung, BT
    Lin, KP
    MEDICAL IMAGING 2004: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2004, 5 (23): : 761 - 768
  • [7] Parametric image reconstruction using spectral analysis of PET projection data
    Meikle, SR
    Matthews, JC
    Cunningham, VJ
    Bailey, DL
    Livieratos, L
    Jones, T
    Price, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (03): : 651 - 666
  • [8] KINETIC MODELING OF RECEPTOR LIGAND-BINDING APPLIED TO POSITRON EMISSION TOMOGRAPHIC STUDIES WITH NEUROLEPTIC TRACERS
    LOGAN, J
    WOLF, AP
    SHIUE, CY
    FOWLER, JS
    JOURNAL OF NEUROCHEMISTRY, 1987, 48 (01) : 73 - 83
  • [9] Image-wise model fitting for generating parametric images in dynamic PET studies.
    Huang, SC
    Zhou, Y
    Stout, D
    Barrio, JR
    PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1998, 1998, 3337 : 198 - 202
  • [10] Improved parametric image generation using spatial-temporal analysis of dynamic PET studies
    Zhou, Y
    Huang, SC
    Bergsneider, M
    Wong, DF
    NEUROIMAGE, 2002, 15 (03) : 697 - 707