Evaluation of a human bio-engineered skin equivalent for drug permeation studies

被引:65
|
作者
Asbill, C
Kim, N
El-Kattan, A
Creek, K
Wertz, P
Michniak, B
机构
[1] Univ S Carolina, Coll Pharm, Dept Basic Pharmaceut Sci, Columbia, SC 29208 USA
[2] Univ S Carolina, Sch Med, Dept Pediat, Childrens Canc Res Lab, Columbia, SC 29208 USA
[3] Univ S Carolina, Sch Med, Dept Pathol, Columbia, SC 29208 USA
[4] Univ Iowa, Dows Inst, Iowa City, IA 52242 USA
关键词
drug delivery systems; skin alternatives; transdermal drug delivery; permeability;
D O I
10.1023/A:1026405712870
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose. To test the barrier function of a bio-engineered human skin (BHS) using three model drugs (caffeine, hydrocortisone, and tamoxifen) in vitro. To investigate the lipid composition and microscopic structure of the BHS. Methods. The human skin substitute was composed of both epidermal and dermal layers, the latter having a bovine collagen matrix. The permeability of the BHS to three model drugs was compared to that obtained in other percutaneous testing models (human cadaver skin, hairless mouse skin, and EpiDerm(TM)). Lipid analysis of the BHS was performed by high performance thin layered chromatography. Histological evaluation of the BHS was performed using routine H&E staining. Results. The BHS mimicked human skin in terms of lipid composition, gross ultrastructure, and the formation of a stratum corneum. However, the permeability of the BHS to caffeine, hydrocortisone, and tamoxifen was 3-4 fold higher than that of human cadaver skin. Conclusions. In summary, the results indicate that the BHS may be an acceptable in vitro model for drug permeability testing.
引用
收藏
页码:1092 / 1097
页数:6
相关论文
共 50 条
  • [1] Evaluation of a Human Bio-Engineered Skin Equivalent for Drug Permeation Studies
    Charles Asbill
    Nanhye Kim
    Ayman El-Kattan
    Kim Creek
    Philip Wertz
    Bozena Michniak
    Pharmaceutical Research, 2000, 17 : 1092 - 1097
  • [2] Skin homeostasis evaluation of an autologous model of human bio-engineered skin in a GMP facility
    Arias-Santiago, Salvador
    Ruiz-Garcia, Antonio
    Lizana, Antonio
    Blasco-Morente, Gonzalo
    Kim, Kevin
    Aneiros-Fernandez, Jose
    Arrabal, Miguel
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2016, 74 (05) : AB36 - AB36
  • [3] Bio-engineered model eye for in-vitro drug permeation using photokinetic delivery
    Godley, Bernard F.
    Kraft, Edward
    Zhao, Zhen-Yang
    Elkeeb, Ahmed
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [4] COMBINING BIO-ENGINEERED HUMAN SKIN WITH BIO-PRINTED CARTILAGE FOR EAR RECONSTRUCTION
    Zielinska, Dominika
    Fisch, Philipp
    Zenobi-Wong, Marcy
    Biedermann, Thomas
    Klar, Agnes
    TISSUE ENGINEERING PART A, 2022, 28 : S548 - S549
  • [5] OPTIMIZATION OF HUMAN KERATINOCYTE CULTURE TO DEVELOP A TISSUE BIO-ENGINEERED HUMAN SKIN MODEL
    Guerrero-Calvo, J.
    Fernandez-Gonzalez, A.
    Lizana-Moreno, A.
    Montes-Ramos, P.
    Fernandez, N.
    Ruiz-Garcia, A.
    Espinosa, O.
    Ordonez-Luque, A.
    Sierra-Sanchez, A.
    Arias-Santiago, S.
    CYTOTHERAPY, 2017, 19 (05) : S136 - S137
  • [6] Studies of nanoparticle delivery with in vitro bio-engineered microtissues
    Sun, Mingze
    Lee, Jinhyung
    Chen, Yupeng
    Hoshino, Kazunori
    BIOACTIVE MATERIALS, 2020, 5 (04) : 924 - 937
  • [7] CLINICAL, HISTOLOGICAL AND HOMEOSTASIS EVALUATION OF TISSUE BIO-ENGINEERED SKIN SUBSTITUTE: IN VIVO MOUSE MODEL
    Fernandez-Gonzalez, A.
    Lizana-Moreno, A.
    Guerrero, J.
    Ruiz-Garcia, A.
    Fernandez, N.
    Espinosa, O.
    Ordonez-Luque, A.
    Sierra-Sanchez, A.
    Arias-Santiago, S.
    CYTOTHERAPY, 2017, 19 (05) : S27 - S27
  • [8] Human fetal skin derived merkel cells display distinctive characteristics in vitro and in bio-engineered skin substitutes in vivo
    Michalak-Micka, Katarzyna
    Rütsche, Dominic
    Mazzone, Luca
    Büchler, Vanessa L.
    Moehrlen, Ueli
    Klar, Agnes S.
    Biedermann, Thomas
    Frontiers in Bioengineering and Biotechnology, 2022, 10
  • [9] Human Immune Response to Xenogeneic Bio-engineered Tooth Root
    Li, H.
    Li, J.
    Tian, W.
    TISSUE ENGINEERING PART A, 2015, 21 : S399 - S399
  • [10] Bio-engineered human kidney for the study of nephrotoxicity and kidney disease
    DesRochers, T. M.
    Ko, W.
    Subramanian, B.
    Perrone, R.
    Shah, J. V.
    Kaplan, D. L.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 126 - 126