Estimating Dynamic Lung Images from High-Dimension Chest Surface Motion Using 4D Statistical Model

被引:0
|
作者
He, Tiancheng [1 ]
Xue, Zhong [1 ]
Yu, Nam [1 ]
Nitsch, Paige L. [1 ]
Teh, Bin S. [1 ]
Wong, Stephen T. [1 ]
机构
[1] Weill Cornell Med Coll, Houston Methodist Res Inst, Houston, TX 77030 USA
关键词
high-dimensional respiratory motion estimation; statistical model; CT; FRAMEWORK;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Computed Tomography (CT) has been widely used in image-guided procedures such as intervention and radiotherapy of lung cancer. However, due to poor reproducibility of breath holding or respiratory cycles, discrepancies between static images and patient's current lung shape and tumor location could potentially reduce the accuracy for image guidance. Current methods are either using multiple intra-procedural scans or monitoring respiratory motion with tracking sensors. Although intra-procedural scanning provides more accurate information, it increases the radiation dose and still only provides snapshots of patient's chest. Tracking-based breath monitoring techniques can effectively detect respiratory phases but have not yet provided accurate tumor shape and location due to low dimensional signals. Therefore, estimating the lung motion and generating dynamic CT images from real-time captured high-dimensional sensor signals acts as a key component for image-guided procedures. This paper applies a principal component analysis (PCA)-based statistical model to establish the relationship between lung motion and chest surface motion from training samples, on a template space, and then uses this model to estimate dynamic images for a new patient from the chest surface motion. Qualitative and quantitative results showed that the proposed high-dimensional estimation algorithm yielded more accurate 4D-CT compared to fiducial marker-based estimation.
引用
收藏
页码:138 / 145
页数:8
相关论文
共 50 条
  • [1] Statistical Modeling of 4D Respiratory Lung Motion Using Diffeomorphic Image Registration
    Ehrhardt, Jan
    Werner, Rene
    Schmidt-Richberg, Alexander
    Handels, Heinz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 251 - 265
  • [2] A 4D Statistical Model of Wrist Bone Motion Patterns
    van de Giessen, Martijn
    Foumani, Mahyar
    Vos, Frans M.
    Strackee, Simon D.
    Maas, Mario
    Van Vliet, Lucas J.
    Grimbergen, Cornelis A.
    Streekstra, Geert J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) : 613 - 625
  • [3] Planning lung radiotherapy using 4D CT data and a motion model
    Colgan, R.
    McClelland, J.
    McQuaid, D.
    Evans, P. M.
    Hawkes, D.
    Brock, J.
    Landau, D.
    Webb, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20): : 5815 - 5830
  • [4] Physiological and Biomechanical Model of Patient Specific Lung Motion Based on 4D CT Images
    Ladjal, Hamid
    Skendraoui, Nadir
    Giroux, Matthieu
    Touileb, Yazid
    Azencot, Joseph
    Shariat, Behzad
    Ladjal, Hamid
    Beuve, Michael
    Giraud, Philippe
    2015 8TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2015,
  • [5] Lung tumor segmentation in 4D CT images using motion convolutional neural networks
    Momin, Shadab
    Lei, Yang
    Tian, Zhen
    Wang, Tonghe
    Roper, Justin
    Kesarwala, Aparna H.
    Higgins, Kristin
    Bradley, Jeffrey D.
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL PHYSICS, 2021, 48 (11) : 7141 - 7153
  • [6] Monte Carlo dose calculation procedure using a 4D motion simulating chest model
    Zhang, J.
    Xu, X. George
    Shi, C.
    Fuss, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2294 - 2294
  • [7] Reconstruction of heart motion from 4D echocardiographic images
    Chlebiej, Michal
    Nowinski, Krzysztof
    Scislo, Piotr
    Bala, Piotr
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, PROCEEDINGS, 2007, 4673 : 245 - 252
  • [8] Tracking the motion trajectories of junction structures in 4D CT images of the lung
    Xiong, Guanglei
    Chen, Chuangzhen
    Chen, Jianzhou
    Xie, Yaoqin
    Xing, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15): : 4905 - 4930
  • [9] Estimating pulmonary arterial pressure from 4D flow images
    Zhang, Chi
    Dong, Yaowen
    Liu, Tongxi
    She, Jin
    Yang, Jian
    Li, Deyu
    Xie, Sheng
    MEDICINE IN NOVEL TECHNOLOGY AND DEVICES, 2025, 26
  • [10] Image quality enhancement using motion estimation in 4D CT images of lung cancer patients
    Wolthaus, J.
    Sonke, J.
    van Herk, M.
    Zijp, L.
    Lebesque, J.
    Damen, E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S110 - S110