Placement of iliosacral screws using 3D image-guided (O-Arm) technology and Stealth Navigation COMPARISON WITH TRADITIONAL FLUOROSCOPY

被引:36
|
作者
Theologis, A. A. [1 ]
Burch, S. [1 ]
Pekmezci, M. [1 ]
机构
[1] Univ Calif San Francisco, Dept Orthopaed Surg, 500 Parnassus MU West 3rd Floor, San Francisco, CA 94143 USA
来源
BONE & JOINT JOURNAL | 2016年 / 98B卷 / 05期
关键词
INTRAOPERATIVE COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; ASSISTED SURGERY; SPINE SURGEON; INSERTION; FIXATION; SYSTEM; REDUCE; MALPOSITION; FRACTURES;
D O I
10.1302/0301-620X.98B5.36287
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Materials and Methods Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. Results There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (SD) 1922) than during fluoroscopy (11.9 mRem SD 14.8) (p < 0.01). Conclusion O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy.
引用
收藏
页码:696 / 702
页数:7
相关论文
共 50 条
  • [1] Safety and Efficacy of Reconstruction of Complex Cervical Spine Pathology Using Pedicle Screws Inserted with Stealth Navigation and 3D Image-Guided (O-Arm) Technology
    Theologis, Alexander A.
    Burch, Shane
    SPINE, 2015, 40 (18) : 1397 - 1406
  • [2] Comparison of 3D C-arm fluoroscopy and 3D image-guided navigation for minimally invasive pelvic surgery
    Bin Li
    Jiliang He
    Zexing Zhu
    Dongsheng Zhou
    Zhenhai Hao
    Yonghui Wang
    Qinghu Li
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1527 - 1534
  • [3] Comparison of 3D C-arm fluoroscopy and 3D image-guided navigation for minimally invasive pelvic surgery
    Li, Bin
    He, Jiliang
    Zhu, Zexing
    Zhou, Dongsheng
    Hao, Zhenhai
    Wang, Yonghui
    Li, Qinghu
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (10) : 1527 - 1534
  • [4] The Accuracy of Navigation and 3D Image-Guided Placement for the Placement of Pedicle Screws in Congenital Spine Deformity
    Larson, A. Noelle
    Polly, David W., Jr.
    Guidera, Kenneth J.
    Mielke, Cary H.
    Santos, Edward R. G.
    Ledonio, Charles Gerald T.
    Sembrano, Jonathan N.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2012, 32 (06) : E23 - E29
  • [5] Positioning of sacroiliac screws using an intraoperative 3D CT (O-Arm©) guided navigation in posterior pelvic ring fractures
    Potocnik, Primoz
    Arigoni, Michele
    Candrian, Christian
    SWISS MEDICAL WEEKLY, 2013, 143 : 29S - 29S
  • [6] Conventional fluoroscopy-guided percutaneous placement of iliosacral screws in the era of intraoperative 3D imaging and navigation: inappropriate or still a valid option?
    Kuttner, H.
    Benninger, E.
    Meier, C.
    BRITISH JOURNAL OF SURGERY, 2019, 106 : 22 - 22
  • [7] Differences in Accuracy and Radiation Dose in Placement of Iliosacral Screws: Comparison between 3D and 2D Fluoroscopy
    Kulakowski, Michal
    Reichert, Pawel
    Elster, Karol
    Witkowski, Jaroslaw
    Sleczka, Pawel
    Morasiewicz, Piotr
    Oleksy, Lukasz
    Krolikowska, Aleksandra
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (06)
  • [8] Comparing the Efficiency, Radiation Exposure, and Accuracy Using C-Arm versus O-Arm With 3D Navigation in Placement of Transiliac-Transsacral and Iliosacral Screws: A Cadaveric Study Evaluating an Early Career Surgeon
    Araiza, Edgar T.
    Medda, Suman
    Plate, Johannes F.
    Marquez-Lara, Alejandro
    Trammell, Amy P.
    Aran, Fernando S.
    Lara, Daniel
    Danelson, Kerry
    Halvorson, Jason J.
    Carroll, Eben A.
    Pilson, Holly T.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (06) : 302 - 306
  • [9] VIRTUAL VISION - ACCURATE 3D IMAGE-GUIDED PLACEMENT OF VERTEBRAL PEDICLE SCREWS
    DISLER, DG
    CARL, AL
    LEHN, JCV
    KHANUJA, PS
    MCCAULEY, TR
    SACHS, BL
    RADIOLOGY, 1995, 197 : 267 - 267
  • [10] Learning curve of 3D fluoroscopy image-guided pedicle screw placement in the thoracolumbar spine
    Ryang, Yu-Mi
    Villard, Jimmy
    Obermueller, Thomas
    Friedrich, Benjamin
    Wolf, Petra
    Gempt, Jens
    Ringel, Florian
    Meyer, Bernhard
    SPINE JOURNAL, 2015, 15 (03): : 467 - 476