Fire ignition of NYM cable shield vapor on excessive electric current in multi core cables

被引:1
|
作者
Setyadi, P. [1 ]
Kusumohadi, C. S. [1 ]
Triyono, T. [1 ]
Yoga, N. G. [1 ]
Sutrisno, H. H. [1 ]
机构
[1] State Univ Jakarta, Jakarta, Indonesia
关键词
D O I
10.1088/1757-899X/1098/6/062087
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
People oftenky use electrical appliances exceeds the technical specifications, but if done technically prevention of the manufacture of the cable to prevent the occurrence of fire, the fire risk will be minimized Under the rules of SNI, heated wires or fed by the overcurrent, to be able to not burn. However, in some ocassions, electrical wires burned and turned into a heat source for fires. NYM cable flame characteristics in the event of overload currents, laminar diffusion flame occurs, the process of liquefaction, pyrolysis, diffusion, and combustion clearly seen. NYM cable flame propagation patterns in the incidence of overload start happening at that point reaches ignition temperature, which occurs due to an electric wire heat reaching the melting temperature of copper. Flame propagates in all directions where their fume and oxygen along the cable and around the cable. In certain circumstances, occur splash / explosion of the fuel to evaporate.
引用
收藏
页数:6
相关论文
共 21 条
  • [2] Ignition and flame propagation of electric cables in a laboratory-scale gallery fire test
    Nakagawa, Yuichi
    Komai, Takeshi
    Kohno, Makoto
    Fire and Materials, 1992, 16 (04) : 181 - 186
  • [3] Cable tray fire tests with halogenated electric cables in a confined and mechanically ventilated facility
    Zavaleta, Pascal
    Suard, Sylvain
    Audouin, Laurent
    FIRE AND MATERIALS, 2019, 43 (05) : 543 - 560
  • [4] Fire behavior of simulated low voltage intumescent cables with and without electric current
    Sarazin, Johan
    Bachelet, Pierre
    Bourbigot, Serge
    JOURNAL OF FIRE SCIENCES, 2017, 35 (03) : 179 - 194
  • [5] Effect of ferrite core attachment to coaxial cable on differential mode noise caused by braided shield current
    Fujiwara, O
    Ichikawa, T
    Kawada, H
    1997 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, PROCEEDINGS, 1997, : 523 - 526
  • [6] Multi-scale influence of vapor pressure deficit on fire ignition and spread in boreal forest ecosystems
    Sedano, F.
    Randerson, J. T.
    BIOGEOSCIENCES, 2014, 11 (14) : 3739 - 3755
  • [7] Research on non-invasive multi conductor current measurement of three-core cables
    Gao, Gan
    Wen, Yumei
    Li, Ping
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2024, 45 (04): : 127 - 135
  • [8] Experimental study on the influence of layer number and initial ignition location on burning characteristic of multi-layer cable fire
    Chen, Jie
    Qin, Shengze
    Zhao, Xiaolong
    Tong, Yunhe
    Fan, Minghao
    FIRE SAFETY JOURNAL, 2025, 153
  • [9] Analysis of normal-mode noise caused by braided shield current flowing on coaxial cable attached by a ferrite core
    Ichikawa, Takeshi
    Kawada, Hiroyuki
    Fujiwara, Osamu
    Electronics and Communications in Japan, Part I: Communications (English translation of Denshi Tsushin Gakkai Ronbunshi), 1999, 82 (02): : 1 - 10
  • [10] An analysis of normal-mode noise caused by braided shield current flowing on coaxial cable attached by a ferrite core
    Ichikawa, T
    Kawada, H
    Fujiwara, O
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART I-COMMUNICATIONS, 1999, 82 (02): : 1 - 10