From patient-informed to patient-specific organ dose estimation in clinical computed tomography

被引:7
|
作者
Fu, Wanyi [1 ,2 ]
Segars, William P. [1 ,3 ,4 ]
Abadi, Ehsan [1 ,2 ]
Sharma, Shobhit [1 ,5 ]
Kapadia, Anuj J. [1 ,6 ]
Samei, Ehsan [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27708 USA
[2] Duke Univ, Dept Elect & Comp Engn, Durham, NC 27708 USA
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[4] Duke Univ, Dept Radiol, Durham, NC 27710 USA
[5] Duke Univ, Dept Phys, Durham, NC 27706 USA
[6] Duke Univ, Med Phys Grad Program, Durham, NC 27708 USA
基金
美国国家卫生研究院;
关键词
organ dose; Monte Carlo; computational phantom; patient-specific; convolutional neural networks; CT; PHANTOMS; ADULT;
D O I
10.1117/12.2294954
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many hospitals keep a record of dose after each patient's CT scan to monitor and manage radiation risks. To facilitate risk management, it is essential to use the most relevant metric, which is the patient-specific organ dose. The purpose of this study was to develop and validate a patient-specific and automated organ dose estimation framework. This framework includes both patient and radiation exposure modeling. From patient CT images, major organs were automatically segmented using Convolutional Neural Networks (CNNs). Smaller organs and structures that were not otherwise segmented were automatically filled in by deforming a matched XCAT phantom from an existing library of models. The organ doses were then estimated using a validated Monte Carlo (PENELOPE) simulation. The segmentation and deformation components of the framework were validated independently. The segmentation methods were trained and validated using 50-patient CT datasets that were manually delineated. The deformation methods were validated using a leave-one-out technique across 50 existing XCAT phantoms that were deformed to create a patient-specific XCAT for each of 50 targets. Both components were evaluated in terms of dice similarity coefficients (DSC) and organ dose. For dose comparisons, a clinical chest-abdomen-pelvis protocol was simulated under fixed tube current (mA). The organ doses were estimated by a validated Monte Carlo package and compared between automated and manual segmentation and between patient-specific XCAT phantoms and their corresponding XCAT targets. Organ dose for phantoms from automated vs. manual segmentation showed a (similar to)2% difference, and organ dose for phantoms deformed by the study vs. their targets showed a variation of (similar to)5% for most organs. These results demonstrate the great potential to assess organ doses in a highly patient-specific manner.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Comprehensive Implementation of Patient-Informed Organ Dose Estimation for Adult, Pediatric and Pregnant Patients in Clinical Computed Tomography
    Fu, W.
    Segars, P.
    Choudhury, K.
    Kapadia, A.
    Wilson, J.
    Ria, F.
    Samei, E.
    MEDICAL PHYSICS, 2018, 45 (06) : E689 - E689
  • [2] Patient-Informed Organ Dose Estimation in Clinical CT: Implementation and Effective Dose Assessment in 1048 Clinical Patients
    Fu, Wanyi
    Ria, Francesco
    Segars, William Paul
    Choudhury, Kingshuk Roy
    Wilson, Joshua M.
    Kapadia, Anuj J.
    Samei, Ehsan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 216 (03) : 824 - 834
  • [3] Patient-specific organ and effective dose estimates in pediatric oncology computed tomography
    Gao, Yiming
    Quinn, Brian
    Pandit-Taskar, Neeta
    Behr, Gerald
    Mahmood, Usman
    Long, Daniel
    Xu, X. George
    St.Germain, Jean
    Dauer, Lawrence T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 146 - 155
  • [4] Multi-organ segmentation in clinical computed tomography for patient-specific image quality and dose metrology
    Fu, Wanyi
    Sharma, Shobhit
    Smith, Taylor
    Hou, Rui
    Abadi, Ehsan
    Selvakumaran, Vignesh
    Tang, Ruixiang
    Lo, Joseph Y.
    Segars, W. Paul
    Kapadia, Anuj J.
    Solomon, Justin B.
    Rubin, Geoffrey D.
    Samei, Ehsan
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [5] Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography
    Segars, W. P.
    Rybicki, K.
    Norris, Hannah
    Frush, D.
    Samei, E.
    MEDICAL PHYSICS, 2014, 41 (12)
  • [6] Rapid patient-specific organ dose estimation in computed tomography scans via integration of radiomics features and neural networks
    Shao, Wencheng
    Lin, Xin
    Huang, Ying
    Qu, Liangyong
    Zhuo, Weihai
    Liu, Haikuan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (10) : 7379 - 7391
  • [7] Patient-specific Effective Dose Estimation from Dose-Length Product in Lung Computed Tomography Using Monte Carlo Simulation
    Fallahmohammadi, Gholamreza
    Nodeh, Zeinab Kordzini
    Mahdavi, Mohammad
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2024, 14 (04):
  • [8] PATIENT-SPECIFIC DOSE ESTIMATES IN DYNAMIC COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION EXAMINATION
    Sundell, V-M
    Kortesniemil, M.
    Siiskonen, T.
    Kosunen, A.
    Rosendahl, S.
    Bueermann, L.
    RADIATION PROTECTION DOSIMETRY, 2021, 193 (01) : 24 - 36
  • [9] Construction of patient-specific computational models for organ dose estimation in radiological imaging
    Xie, Tianwu
    Akhavanallaf, Azadeh
    Zaidi, Habib
    MEDICAL PHYSICS, 2019, 46 (05) : 2403 - 2411
  • [10] Modeling Patient-Informed Liver Contrast Perfusion in Contrast-enhanced Computed Tomography
    Setiawan, Hananiel
    Ria, Francesco
    Abadi, Ehsan
    Fu, Wanyi
    Smith, Taylor B.
    Samei, Ehsan
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (06) : 882 - 886