Correction of distorted 3-D images for misalignment of an optical structure in a multiview 3-D display system

被引:4
|
作者
Kwon, Yongjoon [1 ]
Kim, Donghwan [1 ,2 ]
Kim, Sung-Kyu [1 ]
机构
[1] Korea Inst Sci & Technol, Robot & Media Inst, Ctr Imaging Media Res, Seoul, South Korea
[2] Gachon Univ, Dept Nanophys, Seongnam, South Korea
关键词
autostereoscopic display; multiview three-dimensional display; misalignment; correction of three-dimensional image; AUTOSTEREOSCOPIC 3D DISPLAYS; LENTICULAR DISPLAYS; TECHNOLOGIES; CALIBRATION;
D O I
10.1117/1.OE.57.6.061602
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
For a multiview three-dimensional (3-D) display system using a two-dimensional (2-D) flat panel display, it is very important to attach accurately an optical plate such as a parallax barrier and a lenticular lens sheet onto a 2-D display panel for the best quality of 3-D images. In most practical cases, however, misalignment occurs since it is too difficult to align perfectly in assembly process. In general, angular misalignment results in the deterioration of 3-D image quality by some increase of crosstalk, so that the resulting 3-D images are even distorted as tilted ones. To correct distorted 3-D images, we propose a method to skew 3-D objects before each image for multiviews is taken by multiple cameras. For this, a formula is derived to determine the amount of skewing 3-D objects. And by using it, some experimental results are shown that distorted 3-D images in a misaligned multiview 3-D display system are completely corrected. Since skewing 3-D objects implies a coordinate transformation of 3-D space, this method can be also used in the manipulation of 3-D image data obtained from a depth camera in order to correct the distorted 3-D images caused by angular misalignment. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Crosstalk in multiview 3-D images
    Son, Jung-Young
    Lee, Beom-Ryeol
    Park, Min-Chul
    Leportier, Thibault
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2015, 2015, 9495
  • [2] 3-D TV and display using multiview
    Son Jung-Young
    Kim Shin-Hwan
    Park Min-Chul
    Kim Sung-Kyu
    SPECIAL SESSIONS ON FOOD SAFETY, VISUAL ANALYTICS, RESOURCE RESTRICTED EMBEDDED AND SENSOR NETWORKS, AND 3D IMAGING AND DISPLAY, 2008, 6983
  • [3] 3-D SEGMENTATION OF MR IMAGES OF THE HEAD FOR 3-D DISPLAY
    BOMANS, M
    HOHNE, KH
    TIEDE, U
    RIEMER, M
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (02) : 177 - 183
  • [4] Stereoscopic 3-D display system using dynamic optical correction
    Shibata, T
    Kawai, T
    Otsuki, M
    Miyake, N
    Yoshihara, Y
    Terashima, N
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 2004, 39 (5-6) : 3 - 3
  • [5] 3-D DISPLAY SYSTEM
    GOLDBERG, AA
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1962, 50 (12): : 2521 - &
  • [6] Wide viewing angle floating 3-D display system (with no 3-D glasses)
    Dolgoff, G
    PROJECTION DISPLAYS IV, 1998, 3296 : 186 - 190
  • [7] Multiview 3-D photography simplified
    不详
    PHOTONICS SPECTRA, 2013, 47 (09) : 32 - 33
  • [8] Examination of a stereoscopic 3-D display system using a correction lens
    Kawai, T
    Shibata, T
    Ohta, K
    Yoshihara, Y
    Inoue, T
    Iwasaki, T
    STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS X, 2003, 5006 : 254 - 262
  • [9] Realization of electronic 3-D display combining multiview and volumetric solutions
    Ebisu, Hiromitsu
    Kimura, Tetsuya
    Kakeya, Hideki
    STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XIV, 2007, 6490
  • [10] INTERACTIVE DISPLAY AND ANALYSIS OF 3-D MEDICAL IMAGES
    ROBB, RA
    BARILLOT, C
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (03) : 217 - 226