Fast digitization and discrimination of prompt neutron and photon signals using a novel silicon carbide detector

被引:0
|
作者
Blackburn, Brandon W. [1 ]
Johnson, James T. [1 ]
Watson, Scott M. [1 ]
Chichester, David L. [1 ]
Jones, James L. [1 ]
Ruddy, Frank H. [2 ]
Seidel, John G. [2 ]
Flammang, Robert W. [2 ]
机构
[1] Idaho Natl Lab, 2525 N Fremont Ave MS-2802, Idaho Falls, ID 83415 USA
[2] Westinghouse Elect Co, Sci & Technol Dept, Pittsburgh, PA 15235 USA
关键词
SNM; active inspection; silicon carbide; digitization; pulse shape discrimination;
D O I
10.1117/12.722921
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Current requirements of some Homeland Security active interrogation projects for the detection of Special Nuclear Material (SNM) necessitate the development of faster inspection and acquisition capabilities. In order to do so, fast detectors which can operate during and shortly after intense interrogation radiation flashes are being developed. Novel silicon carbide (SiC) semiconductor Schottky diodes have been utilized as robust neutron and photon detectors in both pulsed photon and pulsed neutron fields and are being integrated into active inspection environments to allow exploitation of both prompt and delayed emissions. These detectors have demonstrated the capability of detecting both photon and neutron events during intense photon flashes typical of an active inspection environment. Beyond the inherent insensitivity of SiC to gamma radiation, fast digitization and processing has demonstrated that pulse shape discrimination (PSD) in combination with amplitude discrimination can ftirther suppress unwanted gamma signals and extract fast neutron signatures. Usable neutron signals have been extracted from mixed radiation fields where the background has exceeded the signals of interest by > 1000:1.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Fast neutron spectrometry using silicon carbide detectors
    Ruddy, FH
    Dulloo, AR
    Petrovic, B
    Seidel, JG
    REACTOR DOSIMETRY IN THE 21ST CENTURY, 2003, : 347 - 355
  • [2] TCAD assisted analysis of Silicon Carbide based Fast Neutron Detector for nuclear applications
    Tripathi, Shivang
    Upadhyay, Chandrakant
    Nagaraj, C. P.
    Devan, K.
    Venkatesan, A.
    Panigrahi, B. K.
    2017 IEEE 12TH NANOTECHNOLOGY MATERIALS AND DEVICES CONFERENCE (NMDC), 2017, : 190 - 191
  • [3] Pulse Shape Discrimination for a Fast Neutron Detector
    Coakley, Kevin J.
    Vecchia, Dominic F.
    Nico, Jeffrey S.
    Fisher, Brian M.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2259 - +
  • [4] Fast neutron dosimetry and spectrometry using silicon carbide semiconductor detectors
    Westinghouse Electric Company, 1332 Beulah Road, Pittsburgh, PA 15235-5081
    J. ASTM Int., 2006, 3
  • [5] Fast neutron dosimetry and spectrometry using silicon carbide semiconductor detectors
    Ruddy, Frank H.
    Seidel, John G.
    Dulloo, Abdul R.
    REACTOR DOSIMETRY: 12TH INTERNATIONAL SYMPOSIUM, 2008, 1490 : 408 - 415
  • [6] Transient Current Analysis of Silicon Carbide Neutron Detector Using SRIM and TCAD
    Zhang, Lilong
    Wang, Ying
    Guo, Haomin
    Yu, Chenghao
    Hu, Haifan
    Liu, Yuntao
    Chen, Size
    IEEE SENSORS JOURNAL, 2022, 22 (11) : 10620 - 10629
  • [7] Improving Detection Efficiency of Silicon Carbide Neutron Detector Using Double Trench
    Zhang, Lilong
    Wang, Ying
    Guo, Haomin
    Hu, Haifan
    Liu, Yuntao
    Chen, Size
    IEEE SENSORS JOURNAL, 2023, 23 (05) : 4302 - 4310
  • [8] PIN silicon diode fast neutron detector
    Zhou, CZ
    Zhao, JX
    Xiao, WY
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (04) : 365 - 368
  • [9] Individual monitoring in mixed neutron/photon fields using a single silicon detector
    Luszik-Bhadra, M
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A179 - A182
  • [10] Individual monitoring in mixed neutron/photon fields using a single silicon detector
    Luszik-Bhadra, M
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 179 - 182