Pulse wave velocity measurement along the ulnar artery in the wrist region using a high-frequency ultrasonic probe with H-topology

被引:0
|
作者
Benchemoul, Maxime [1 ,2 ]
Mateo, Tony [1 ]
Savery, David [1 ]
Gehin, Claudine [1 ,2 ]
Massot, Bertrand [1 ,2 ]
Ferin, Guillaume [1 ]
Vince, Philippe [1 ]
Flesch, Martin [1 ]
机构
[1] Vermon SA, Act Probe Dept, F-37000 Tours, France
[2] Univ Lyon, INSA Lyon, ECL, CNRS,UCBL,CPE Lyon,INL,UMR5270, F-69621 Villeurbanne, France
关键词
Pulse wave velocity; pulse transit time; monolithic probe; H-topology; high-frequency; multiplane imaging; superficial arteries; ATHEROSCLEROSIS;
D O I
10.1109/IUS52206.2021.9593834
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Cardiovascular diseases (CVD) are considered as the main cause of death representing more than 30% of worldwide casualties according to the World Health Organization [1]. The pulse wave velocity (PWV) is a relevant indicator of CVD [2] at an early stage since it directly reflects the age and stiffness of the arterial network. A PWV measurement method using a high-frequency (15 MHz) ultrasound probe with a H-topology made for vascular imaging is presented in this paper. The probe includes a longitudinal 128-element linear array at the center of the probe and two orthogonal 64-element linear arrays on each side of the probe. This solution makes the probe very well suited to the anatomy of smaller arteries, enabling both longitudinal and cros-ssectional simultaneous imaging of the artery of interest. High frame-rate (HFR) plane wave imaging (10 000 frames per second) is employed for a precise PWV measurement which is performed in-vivo on a healthy volunteer. The long-term objective of this work is to develop an innovative device using a dedicated ultrasonic probe and integrating a miniaturized electronic system. The system would be able to automatically drive the probe, collect data and calculate the PWV in ambulatory situations, on-demand or during periodical routine check-ups. The device would be used at the wrist above the ulnar artery to measure the local PWV.
引用
收藏
页数:4
相关论文
共 5 条
  • [1] Pulse wave velocity measurement along the ulnar artery in the wrist region using a high frequency ultrasonic array
    Benchemoul, Maxime
    Mateo, Tony
    Savery, David
    Gehin, Claudine
    Massot, Bertrand
    Ferin, Guillaume
    Vince, Philippe
    Flesch, Martin
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4123 - 4127
  • [2] Pulse Wave Velocity Doppler Measurement of Ulnar Artery Using a High-Frequency Probe
    Benchemoul, Maxime
    Savery, David
    Gehin, Claudine
    Massot, Bertrand
    Ferin, Guillaume
    Vince, Philippe
    Flesch, Martin
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [3] A high-frequency linear probe with H-topology for PWV measurements on superficial arteries
    Benchemoul, Maxime
    Lejeune, Agnes
    Porcher, Nicolas
    Montauban, Emmanuel
    Ferin, Guillaume
    Gehin, Claudine
    Massot, Bertrand
    Vince, Philippe
    Flesch, Martin
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [4] Ultrasonic Measurement of Axial Stress Using High-Frequency Cylindrical Guided Wave
    Chen, Ping
    He, Xingliang
    Wang, Xinyu
    IEEE SENSORS JOURNAL, 2021, 21 (05) : 6691 - 6697
  • [5] MEASUREMENT OF RETINAL ARTERY PULSE WAVE VELOCITY IN THE RAT USING HIGH SPEED IMAGING
    Golzan, S. M.
    Butlin, M.
    Kouchaki, Z.
    Avolio, A. P.
    Graham, S. L.
    HYPERTENSION, 2014, 63 (06) : E147 - E147