A continuous, hybrid field-gradient device for magnetic colloid-based separations

被引:3
|
作者
Ghebremeskel, AN [1 ]
Bose, A [1 ]
机构
[1] Univ Rhode Isl, Dept Chem Engn, Kingston, RI 02881 USA
关键词
colloid-based separations; hybrid field gradient;
D O I
10.1016/S0304-8853(02)01414-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A fully continuous, hybrid field-gradient device is developed for colloidal magnetic affinity separation. The device consists of a 1.0 cm internal diameter 1.2 m long, axially rotating horizontal glass chamber, with four repeating magnetic units distributed axially along the tube. Each magnetic unit consists of a stationary alternating-current solenoid that surrounds the chamber, followed by a direct current flowing, computer-controlled electromagnet, placed at a distance of 4.0 cm from the end of the solenoid. The alternating-current-carrying solenoids impart translational and rotary oscillations to the magnetic particles, enhancing mixing. The computer-controlled electromagnets draw the magnetic particles to the chamber walls, and increase their residence time in the chamber. By manipulating the on-off cycle for these electromagnets, the exiting solution can be switched between one that contains a negligible concentration of target-bound magnetic particles and one that has a high concentration of the target, without interrupting the feed. The operation of this device is demonstrated for the removal of cadmium ions from a cadmium sulfate solution. 1-10 mum diameter anion-exchange-resin-coated magnetic particles at a concentration of 0.5 mg particles/ml were used as the mobile solid support. The feed consisted of a 10.0 mg/l cadmium sulfate solution, at a flow rate of 25 ml/min. The device was operated as a three-stage cross-current cascade. For this system, 45%, 58% and 63% of the entering cadmium ions are removed at each stage, respectively, with stage efficiencies that vary. between 57% and 65%. Thus, more than 90% of the entering cadmium ions are removed. While this device has been demonstrated for metal ion removal from an aqueous feed, it can potentially be applied to several other affinity-based separations. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:66 / 72
页数:7
相关论文
共 50 条
  • [1] Magnetic colloid mediated recovery of cadmium ions from an aqueous solution using a flow-through hybrid field-gradient device
    Ghebremeskel, AN
    Bose, A
    SEPARATION SCIENCE AND TECHNOLOGY, 2002, 37 (03) : 555 - 569
  • [2] Magnetic colloid mediated recovery of cadmium ions from an aqueous solution using a flow-through hybrid field-gradient device.
    Ghebremeskel, A
    Bose, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U579 - U580
  • [3] Removal of As(V) and Cr(VI) ions from aqueous solution using a continuous, hybrid field-gradient magnetic separation device
    Jha, Ashish K.
    Bose, Arijit
    Downey, Jerome P.
    SEPARATION SCIENCE AND TECHNOLOGY, 2006, 41 (15) : 3297 - 3312
  • [4] A flow-through, hybrid magnetic-field-gradient, rotating wall device for magnetic colloidal separations
    Ghebremeskel, AN
    Bose, A
    SEPARATION SCIENCE AND TECHNOLOGY, 2000, 35 (12) : 1813 - 1828
  • [5] DESIGN OF A MAGNETOMETER AND OF A MAGNETIC FIELD-GRADIENT METER
    SPIGHEL, M
    JOURNAL DE PHYSIQUE ET LE RADIUM, 1957, 18 (07): : A108 - A111
  • [6] A structural study of hybrid organosilica materials for colloid-based DNA biosensors
    Corrie, Simon R.
    Vogel, Robert
    Keen, Imelda
    Jack, Kevin
    Kozak, Darby
    Lawrie, Gwendolyn A.
    Battersby, Bronwyn J.
    Fredericks, Peter
    Trau, Matt
    JOURNAL OF MATERIALS CHEMISTRY, 2008, 18 (05) : 523 - 529
  • [7] Localization error of magnetic dipole by measuring remote magnetic field and field-gradient tensor
    Wang Sansheng
    Shi Guoqiang
    Zhang Mingji
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 779 - 786
  • [8] Partial measurements of the total field gradient and the field-gradient tensor using an atomic magnetic gradiometer
    Yu, Q. -Q
    Liu, S. -Q
    Wang, X. -K
    Sheng, D.
    PHYSICAL REVIEW A, 2023, 107 (04)
  • [9] High field-gradient dysprosium tips for magnetic resonance force microscopy
    Mamin, H. J.
    Rettner, C. T.
    Sherwood, M. H.
    Gao, L.
    Rugar, D.
    APPLIED PHYSICS LETTERS, 2012, 100 (01)
  • [10] SPECTROSCOPIC MEASUREMENT OF CYCLOTRON RADIATIONS FROM LINEAR DEVICE WITH FIELD-GRADIENT ALONG THE AXIS
    NAGATSU, M
    INUZUKA, H
    TSUKISHIMA, T