123I-IMT SPECT and 1H MR-spectroscopy at 3.0 T in the differential diagnosis of recurrent or residual gliomas:: a comparative study

被引:74
|
作者
Plotkin, M
Eisenacher, J
Bruhn, H
Wurm, R
Michel, R
Stockhammer, F
Feussner, A
Dudeck, O
Wust, P
Felix, R
Amthauer, H
机构
[1] Univ Klin Charite, Klin Strahlenheilkunde, D-13353 Berlin, Germany
[2] Klin Strahlentherapie, Berlin, Germany
[3] Charite, Neurochirurg Klin, Berlin, Germany
关键词
3-[I-123]iodine-a-methyl-L-tyrosine; proton magnetic resonance spectroscopy; recurrent glioma; single photon emission tomography; 3.0; T;
D O I
10.1023/B:NEON.0000040810.77270.68
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this investigation was to compare two current non-invasive modalities, single photon emission tomography ( SPECT) using 123-iodine-alpha-methyl tyrosine (I-123-IMT) and single-voxel proton magnetic resonance spectroscopy (H-1-MRS) at 3.0 T, with regard to their ability to differentiate between residual/ recurrent tumors and treatment-related changes in patients pretreated for glioma. The patient population comprised 25 patients in whom recurrent glioma was suspected based on MR imaging. SPECT imaging started 10 min after iv. injection of 300-370 MBq I-123-IMT and was performed using a triple-head system. The IMT uptake was calculated semiquantitatively using regions-of-interest. H-1-MRS was performed at 3.0 T using the single-volume point-resolved spectroscopy (PRESS) technique. Guided by MR imaging volumes-of-interest for spectroscopy were placed into the suspected lesions. Signal intensities of choline-containing compounds (Cho), creatine and phosphocreatine (Cr), and N-acetylaspartate (NAA) were obtained. When using the cut-off of 1.62 for I-123-IMT uptake, the sensitivity, specificity, and accuracy of the I-123-IMT SPECT were 95, 100 and 96%, respectively. For H-1-MRS, the sensitivity, specificity and accuracy were 89, 83 and 88%, respectively, based both on the metabolic ratios of Cho/Cr and Cho/NAA as tumor criterion with cut-off values of 1.11 and 1.17, respectively. In conclusion, I-123-IMT SPECT yielded more favorable results compared to H-1-MRS at distinguishing recurrent and/or residual glioma from posttherapeutic changes and may be particularly valuable when the evaluation of tumor extent is necessary.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 2 条
  • [1] 123I-IMT SPECT and 1HMR-Spectroscopy at 3.0T in the Differential Diagnosis of Recurrent or Residual Gliomas: A Comparative Study
    Michail Plotkin
    Julia Eisenacher
    Harald Bruhn
    Reinhard Wurm
    Roger Michel
    Florian Stockhammer
    Annelie Feußner
    Oliver Dudeck
    Peter Wust
    Roland Felix
    Holger Amthauer
    Journal of Neuro-Oncology, 2004, 70 : 49 - 58
  • [2] Metabolic imaging to follow stereotactic radiation of gliomas -: the role of 1H MR spectroscopy in comparison to FDG-PET and IMT-SPECT
    Lichy, MP
    Henze, M
    Plathow, C
    Bachert, P
    Kauczor, HU
    Schlemmer, HP
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (08): : 1114 - 1121