Monte Carlo simulation-based design for an electron-linear-accelerator-driven subcritical neutron multiplier for boron neutron capture therapy

被引:2
|
作者
Hiraga, F. [1 ]
机构
[1] Hokkaido Univ, Fac Engn, Div Quantum Sci & Engn, Kita Ku, Kita 13,Nishi 8, Sapporo, Hokkaido 0608628, Japan
关键词
Electron linear accelerator; Subcritical neutron multiplier; Fuel configurations; Epithermal neutron flux; Beam characteristics; Boron neutron capture therapy;
D O I
10.1016/j.apradiso.2018.06.023
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Fuel configurations for a subcritical neutron multiplier, which was embedded in a beam-shaping assembly and irradiated by electrons from a linear accelerator, were examined to maximize the production of the epithermal neutron flux for boron neutron capture therapy. The epithermal neutron flux at the treatment position increased as the area per uranium fuel plate increased and was estimated to be 2 x 10(9) cm(-2) s(-1) when the subcritical neutron multiplier was irradiated by a 4.4 kW (0.22 mA) beam of 20 MeV electrons.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [1] Monte Carlo simulation-based design of an electron-linear accelerator-based neutron source for boron neutron capture therapy
    Hiraga, F.
    APPLIED RADIATION AND ISOTOPES, 2020, 162
  • [2] Monte Carlo simulation of boron neutron capture therapy
    Qiu, YH
    Li, D
    Ying, YJ
    Xiao, G
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 27 (10): : 936 - 942
  • [3] Optimum design and criticality safety of a beam-shaping assembly with an accelerator-driven subcritical neutron multiplier for boron neutron capture therapies
    Hiraga, F.
    APPLIED RADIATION AND ISOTOPES, 2015, 106 : 84 - 87
  • [4] Accelerator-driven boron neutron capture therapy
    Edgecock, Rob
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2014, 29 (14):
  • [5] BORON NEUTRON CAPTURE THERAPY SETUP FOR A LINEAR ACCELERATOR
    Chiojdeanu, C. F.
    Pavel, C.
    Constantin, F.
    ROMANIAN JOURNAL OF PHYSICS, 2009, 54 (7-8): : 641 - 648
  • [6] A shielding design for an accelerator-based neutron source for boron neutron capture therapy
    Hawk, AE
    Blue, TE
    Woollard, JE
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1027 - 1031
  • [7] Accelerator-based neutron source for boron neutron capture therapy
    Ivanov, A. A.
    Smirnov, A. N.
    Taskaev, S. Yu
    Bayanov, B. F.
    Belchenko, Yu, I
    Davydenko, V., I
    Dunaevsky, A.
    Emelev, I. S.
    Kasatov, D. A.
    Makarov, A. N.
    Meekins, M.
    Kuksanov, N. K.
    Popov, S. S.
    Salimov, R. A.
    Sanin, A. L.
    Sorokin, I. N.
    Sycheva, T., V
    Shudlo, I. M.
    Vorob'ev, D. S.
    Cherepkov, V. G.
    Fadeev, S. N.
    PHYSICS-USPEKHI, 2022, 65 (08) : 834 - 851
  • [8] Monte-Carlo simulations of a neutron source based on a linear electron accelerator
    Wasilewski, Adam
    Wronka, Slawomir
    NUKLEONIKA, 2025, 70 (01) : 3 - 10
  • [9] Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy
    Allen, DA
    Beynon, TD
    Green, S
    MEDICAL PHYSICS, 1999, 26 (01) : 71 - 76
  • [10] Neutron beam design and dosimetric evaluation for accelerator-based Boron Neutron Capture Therapy
    Bortolussi, S.
    Postuma, I.
    Protti, N.
    Fatemi, S.
    Magni, C.
    Gonzalez, S.
    Altieri, S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1024 - S1024