Soft x-ray PHA measurement of the long pulse discharge in HT-7 tokamak

被引:0
|
作者
Xu, P. [1 ]
Hu, L. Q. [1 ]
Lin, S. Y. [1 ]
Duan, Y. M. [1 ]
Zhang, J. Z. [1 ]
Zhong, G. Q. [1 ]
Lu, H. W. [1 ]
Chen, K. Y. [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Soft x-ray PHA; Lower hybrid current drive (LHCD); Electron temperature (T-e); Z(eff); HT-7; Long pulse discharge; HEIGHT ANALYZER; CURRENT DRIVE; PLASMA; PERFORMANCE; EFFICIENCY; OPERATION; IMPURITY;
D O I
10.1016/j.physleta.2010.04.005
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
By analyzing the soft x-ray energy spectrum measured by the soft x-ray pulse height analysis (PHA) system, the electron temperature (T-e) and the effective charge number (Z(eff)) of the ultra-long pulse discharge driven by lower hybrid wave (LHW) were obtained in the HT-7 tokamak. Moreover, the information of medium-Z impurities such as Ti, Cr, Fe, and Ni intrinsic to HT-7 tokamak can also be inspected. The accuracy of the electron temperature derived from the soft x-ray energy spectrum measurements is verified by comparing with the temperature measured by the Thomson scattering system for various plasmas and electron cyclotron emission diagnostic system for ohmic plasmas. The bulk electron temperature of about 1 key and Z(eff) approximate to 2 were achieved for long pulse plasma. The appreciable K alpha lines of Ti, Cr, Fe and Ni metallic impurities released from the antennas of radio frequency wave and/or the first wall and Ar injected into plasma can be observed, and they kept stable during the long duration discharges. As a result, the longest pulse discharge with relatively high temperature of T-e(0) similar to 1 key, and n(e)(0) similar to 0.5 x 10(19) m(-3) has been achieved with a duration of 400 s in the HT-7 experimental campaign in 2008. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2452 / 2460
页数:9
相关论文
共 50 条
  • [1] A compact soft X-ray PHA in the HT-7 tokamak
    Chen, ZY
    Wan, BN
    Shi, YJ
    Hu, LQ
    Lin, SY
    Hu, QS
    Lui, SX
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (03): : 604 - 608
  • [2] New soft x-ray PHA diagnostic in the HT-7 tokamak
    Chen, ZY
    Wan, BN
    Shi, YJ
    Liu, SY
    Hu, LQ
    PLASMA SCIENCE & TECHNOLOGY, 2005, 7 (03) : 2813 - 2815
  • [3] New Soft x-ray PHA Diagnostic in the HT-7 Tokamak
    陈忠勇
    万宝年
    石跃江
    林士耀
    胡立群
    Plasma Science & Technology, 2005, (03) : 2813 - 2815
  • [4] Soft x-ray pulse height analyzer in the HT-7 tokamak
    Shi, YJ
    Chen, ZY
    Wan, BN
    Lv, B
    Hu, LQ
    Lin, SY
    Hu, QS
    Qian, JP
    Liu, HQ
    Liu, SX
    Xu, YC
    Shan, JF
    Li, JG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (11): : 4930 - 4933
  • [5] Hard X-Ray PHA System on the HT-7 Tokamak
    林士耀
    石跃江
    万宝年
    陈忠勇
    胡立群
    Plasma Science and Technology, 2006, (03) : 261 - 264
  • [6] Hard X-ray PHA system on the HT-7 tokamak
    Lin Shiyao
    Shi Yuejiang
    Wan Baonian
    Chen Zhongyong
    Hu Liqun
    PLASMA SCIENCE & TECHNOLOGY, 2006, 8 (03) : 261 - 264
  • [7] Hard X-Ray PHA System on the HT-7 Tokamak
    林士耀
    石跃江
    万宝年
    陈忠勇
    胡立群
    Plasma Science and Technology, 2006, 8 (03) : 261 - 264
  • [8] Soft X-ray spectrometer on the HT-7 tokamak
    Liang, Y.
    Yin, X.
    Fang, Z.
    Liang, R.
    Fusion Engineering and Design, 1997, 34-35 : 201 - 204
  • [9] Soft X-ray spectrometer on the HT-7 tokamak
    Liang, YF
    Yin, XJ
    Fang, ZS
    Liang, RQ
    FUSION ENGINEERING AND DESIGN, 1997, 34-35 : 201 - 204
  • [10] Application of avalanche photodiode for soft X-ray pulse-height analyses in the Ht-7 tokamak
    Shi, YJ
    Wan, BN
    Hu, LQ
    Sun, YJ
    Liu, S
    Ling, BL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 488 (03): : 566 - 571