Intra- and inter-observer reproducibility of CINtec® PLUS in ThinPrep® cytology preparations

被引:10
|
作者
McMenamin, M. [1 ]
McKenna, M. [1 ]
McDowell, A. [2 ]
Dawson, C. [3 ]
McKenna, R. [3 ]
机构
[1] Western Hlth & Social Care Trust, Altnagelvin Hosp, Cytopathol Dept, Londonderry, North Ireland
[2] Univ Ulster, Northern Ireland Ctr Stratified Med, Altnagelvin Hosp, Inst Biomed Sci, Londonderry, North Ireland
[3] Belfast Hlth & Social Care Trust, Belfast City Hosp, Cytopathol Dept, Belfast, Antrim, North Ireland
关键词
CINtec (R) PLUS cytology reproducibility; HPV primary screening; ThinPrep (R) LBC; CERVICAL-CANCER PRECURSORS; HUMAN-PAPILLOMAVIRUS; POSITIVE WOMEN; HPV INFECTION; PAP CYTOLOGY; DUAL-STAIN; FOLLOW-UP; ASC-US; SPECIFICITY; NEOPLASIA;
D O I
10.1111/cyt.12426
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background: This study evaluated the intra-and inter-observer reproducibility of the dual-stain biomarker, CINtec (R) PLUS cytology in ThinPrep (R) specimens, for improved specificity in the detection of cervical disease in women testing human papillomavirus (HPV) positive. Methods: A total of 972 cases of HPV-positive women from a triage and primary HPV screening population were selected from an ongoing study evaluating the clinical performance of CINtec (R) PLUS cytology. For reproducibility analyses, three cytotechnologists rescreened sets of slides which they had previously reported themselves and which were previously reported by each of the other cytotechnologists. The original results of slides previously screened by each of the three cytotechnologists were also compared with the results of an expert reference evaluator. Results: Intra-and inter-observer agreement for paired evaluations between reviewers ranged from 82.8% to 94.9% ( kappa 0.65-0.91) and 89.2% to 93% ( kappa 0.83-0.88), respectively. Reproducibility analyses between the cytotechnologists and the reference evaluator revealed agreements ranging from 95.5% to 98% ( kappa 0.89-0.96). Conclusion: Evaluation of the dual-stain biomarker showed a high level of agreement across all evaluators suggesting that CINtec (R) PLUS cytology will perform well in the hands of cytotechnologists and pathologist reviewers and could be introduced into cellular pathology laboratories that employ ThinPrep (R) LBC with a minimum effort.
引用
收藏
页码:284 / 290
页数:7
相关论文
共 50 条
  • [1] Intra- and inter-observer reproducibility in the measurement of central corneal thickness
    Albe, E
    Miglior, S
    Guareschi, M
    Mandelli, G
    Gomarasca, S
    Orzalesi, N
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U512 - U512
  • [2] Intra- and inter-observer reproducibility in the evaluation of the optic disc by HRT.
    Miglior, S
    Albe, E
    Guareschi, M
    Rossetti, L
    Orzalesi, N
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S16 - S16
  • [3] Intra- and inter-observer reproducibility of QRS duration measurement in CRT patients
    Thebault, C.
    Kervio, G.
    Gervais, R.
    Donal, E.
    Mabo, P.
    Linde, C.
    Daubert, C.
    EUROPEAN HEART JOURNAL, 2010, 31 : 266 - 266
  • [4] Intra- and inter-observer reproducibility of masked Goldmann applanation tonometry measurements
    Trevino, Rick
    Majcher, Carolyn
    Sponsel, William Eric
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [5] INTRA- AND INTER-OBSERVER VARIATIONS IN ASSESSMENT OF EMPHYSEMA
    THURLBEC.WM
    HOROWITZ, I
    SIEMIATY.J
    DUNNILL, MS
    MAISEL, JC
    PRATT, P
    RYDER, R
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1969, 18 (04): : 646 - &
  • [6] Influence of experience on intra- and inter-observer reproducibility of the Crowe, Hartofilakidis and modified Cochin classifications
    Clave, A.
    Tristan, L.
    Desseaux, A.
    Gaucher, F.
    Lefevre, C.
    Stindel, E.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (02) : 155 - 159
  • [7] Intra- and inter-observer reproducibility of the recurrent varicose veins after surgery (REVAS) classification
    Perrin, M.
    Allaert, F. A.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2006, 32 (03) : 326 - 332
  • [8] Classification of Minor Stroke: Intra- and Inter-Observer Reliability
    Selvarajah, Johann R.
    Glaves, Matthew
    Wainwright, Jane
    Jha, Animesh
    Vail, Andy
    Tyrrell, Pippa J.
    CEREBROVASCULAR DISEASES, 2009, 27 (03) : 209 - 214
  • [9] Intra- and inter-observer reliability in anthropometric measurements in children
    S Stomfai
    W Ahrens
    K Bammann
    É Kovács
    S Mårild
    N Michels
    L A Moreno
    H Pohlabeln
    A Siani
    M Tornaritis
    T Veidebaum
    D Molnár
    International Journal of Obesity, 2011, 35 : S45 - S51
  • [10] Intra- and inter-observer reliability in anthropometric measurements in children
    Stomfai, S.
    Ahrens, W.
    Bammann, K.
    Kovacs, E.
    Marild, S.
    Michels, N.
    Moreno, L. A.
    Pohlabeln, H.
    Siani, A.
    Tornaritis, M.
    Veidebaum, T.
    Molnar, D.
    INTERNATIONAL JOURNAL OF OBESITY, 2011, 35 : S45 - S51