Validation of hand-held bioelectrical impedance analysis with magnetic resonance imaging for the assessment of body composition in overweight women

被引:12
|
作者
Varady, Krista A.
Santosa, Sylvia
Jones, Peter J. H.
机构
[1] Univ Manitoba, Richardson Ctr Funct Foods & Nutraceut, Winnipeg, MB R3T 6C5, Canada
[2] McGill Univ, Sch Dietet & Human Nutr, Montreal, PQ, Canada
关键词
D O I
10.1002/ajhb.20609
中图分类号
Q98 [人类学];
学科分类号
030303 ;
摘要
Methods of assessing body composition suitable for use in clinical trials should be accurate, reliable, and easy to perform. One such technique routinely implemented is handheld bioelectrical impedance analysis (BIA). The validity of this method, however, in body composition assessment of overweight women is not known. The aim of this study was to validate the hand-held BIA technique with magnetic resonance imaging (MRI) for the assessment of body composition in overweight women. Fat mass, percent fat mass, fat-free mass, and percent fat-free mass values estimated by hand-held BIA were compared to those measured by MRI. Thirty-one Caucasian women (50.1 +/- 8.2 years, body mass index of 26.9 +/- 3.1 kg/m(2)) participated in the study. BIA measurements were highly reproducible (technical error (TE) was 0.06 +/- 0.07 kg for fat mass and 0.08 +/- 0.11% for percent fat mass), but were significantly different (P < 0.0001) for each body composition parameter when compared to MRI. BIA underestimated fat mass by 2.3 +/- 3.3 kg and percent fat mass by 5.6 +/- 3.9%. Likewise, BIA overestimated fat free mass by 7.4 +/- 2.7 kg and percent fat free mass by 5.6 +/- 3.2%. No relationship between the bias and the mean of the two measurements was noted suggesting that bias is not related to measurement size. Although hand-held BIA gives reproducible findings, the bias noted for all body composition parameters puts into question the validity of this regional impedance device for use in clinical trials in overweight women.
引用
收藏
页码:429 / 433
页数:5
相关论文
共 50 条
  • [1] Validation Of Hand-held Bioelectrical Impedance Analysis For The Assessment Of Body Fat In Young And Old Adults
    Wheeler, Lynn A.
    Cashin, Susan E.
    Klos, Lori A.
    Rote, Aubrianne E.
    Clasey, Jody L.
    Swartz, Ann M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 448 - 448
  • [2] Evaluation of Novel Hand-held Wireless Bioelectrical Impedance Analysis (BIA) Body Composition Devices
    Heymsfield, Steven
    Zheng, Jolene
    Wang, Mingming
    Gao, Chenfei
    Kim, Justin Young-Hyun
    Choi, Ahyoung
    Jo, Seong Wook
    Oh, Jung-Taek
    Cho, Jaegeol
    Bhagat, Yusuf
    Kim, Insoo
    FASEB JOURNAL, 2015, 29
  • [3] Postoperative Changes in Body Composition—Comparison of Bioelectrical Impedance Analysis and Magnetic Resonance Imaging in Bariatric Patients
    Mirko Otto
    Julia Färber
    Stefan Haneder
    Henrik Michaely
    Peter Kienle
    Till Hasenberg
    Obesity Surgery, 2015, 25 : 302 - 309
  • [4] VALIDATION OF BIOELECTRICAL IMPEDANCE ANALYSIS FOR THE ASSESSMENT OF BODY COMPOSITION IN PATIENTS WITH SYSTEMIC SCLEROSIS
    Spanjer, M. J.
    Bultink, E. M.
    de van der Schueren, M. A. E.
    Voskuyl, A. E.
    ANNALS OF THE RHEUMATIC DISEASES, 2016, 75 : 527 - 527
  • [5] Validation of a portable bioelectrical impedance analyzer for the assessment of body composition
    Karelis, Antony D.
    Chamberland, Gabriel
    Aubertin-Leheudre, Mylene
    Duval, Christian
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM-PHYSIOLOGIE APPLIQUEE NUTRITION ET METABOLISME, 2013, 38 (01): : 27 - 32
  • [6] Postoperative Changes in Body Composition-Comparison of Bioelectrical Impedance Analysis and Magnetic Resonance Imaging in Bariatric Patients
    Otto, Mirko
    Faerber, Julia
    Haneder, Stefan
    Michaely, Henrik
    Kienle, Peter
    Hasenberg, Till
    OBESITY SURGERY, 2015, 25 (02) : 302 - 309
  • [7] Validation Of Multi-frequency Bioelectrical Impedance Analysis For The Assessment Of Body Composition In Children
    Andreacci, Joseph L.
    Fetterman, Meghan
    Masteller, Brittany
    Dixon, Curt B.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 612 - 612
  • [8] Validation of foot-to-foot bioelectrical impedance analysis in the measurement of body composition in overweight and obese children
    Goldfield, G
    Cloutier, P
    Mallory, R
    Prud'Homme, D
    Parker, T
    Parker, K
    Lumb, A
    Pomerleau, M
    Doucet, E
    OBESITY RESEARCH, 2004, 12 : A121 - A121
  • [9] Assessment of body composition in elderly:: Accuracy of bioelectrical impedance analysis
    Bussolotto, M
    Ceccon, A
    Sergi, G
    Giantin, V
    Benincà, P
    Enzi, G
    GERONTOLOGY, 1999, 45 (01) : 39 - 43
  • [10] External cross-validation of bioelectrical impedance analysis for the assessment of body composition in Korean adults
    Kim, Hyeoijin
    Kim, Chul-Hyun
    Kim, Dong-Won
    Park, Mira
    Park, Hye Soon
    Min, Sun-Seek
    Han, Seung-Ho
    Yee, Jae-Yong
    Chung, Sochung
    Kim, Chan
    NUTRITION RESEARCH AND PRACTICE, 2011, 5 (03) : 246 - 252