A voltammetric study on the interaction between isoproterenol and cardiomyocyte DNA by using a glassy carbon electrode modified with carbon nanotubes, polyaniline and gold nanoparticles

被引:13
|
作者
Wang, Jian [1 ]
Li, Yanfei [2 ,3 ]
Li, Chao [4 ]
Zeng, Xinping [5 ]
Tang, Wenwei [6 ]
Chen, Xuejin [2 ]
机构
[1] Shanghai Jiao Tong Univ, Bio X Inst, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Dept Lab Anim Sci, Shanghai 200025, Peoples R China
[3] Shanghai Univ Med & Hlth Sci, Shanghai Zhoupu Hosp, Shanghai 201318, Peoples R China
[4] Tongji Univ, Sch Med, Shanghai Matern & Infant Hosp 1, Clin & Translat Res Ctr, Shanghai 200092, Peoples R China
[5] Tongji Univ, Sch Life Sci & Technol, Shanghai 200092, Peoples R China
[6] Tongji Univ, Dept Chem, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Isoproterenol; Cardiomyocyte; Electrochemical sensor; DNA damage; Drug side effects; Drug-DNA interaction; Cyclic voltammetry; Electrochemical impedance spectroscopy; ELECTROCHEMICAL DETECTION; CARDIAC-HYPERTROPHY; METHYLENE-BLUE; DAMAGE; GRAPHENE; SENSOR; COMPOSITES; EXPRESSION; SEROTONIN; DOPAMINE;
D O I
10.1007/s00604-017-2295-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An understanding of the mechanism of interaction between the isoproterenol (a beta-adrenoreceptor agonist and TAAR1 agonist) and cardiomyocytes is a crucial area of research in order to overcome the side effects of isoproterenol for clinical treatment. The authors describe an electrochemical method to study the effects and response of cardiomyocyte DNA following treatment with isoproterenol. High-purity DNA was isolated from primary cardiomyocytes and used to modify a glassy carbon electrode (GCE) with a nanocomposite of the type DNA/AuNP/PANI/MWCNT (where AuNP stands for gold nanoparticles, PANI for polyaniline, and MWCNT for multiwalled carbon nanotubes). Isoproterenol has a characteristic differential pulse voltammetric peak at approximately 0.38 V (vs. Ag/AgCl), and this signal was used to monitor interactions with DNA double strand with increasing concentrations of isoproterenol. It is shown that DNA is damaged which can be confirmed by detection of DNA damage-related protein expression. The primary mode of binding between isoproterenol and DNA is demonstrated to be intercalation, and the redox reaction is shown to be controlled by adsorption and to be an irreversible single-electron transfer process.
引用
收藏
页码:2999 / 3006
页数:8
相关论文
共 50 条
  • [1] A voltammetric study on the interaction between isoproterenol and cardiomyocyte DNA by using a glassy carbon electrode modified with carbon nanotubes, polyaniline and gold nanoparticles
    Jian Wang
    Yanfei Li
    Chao Li
    Xinping Zeng
    Wenwei Tang
    Xuejin Chen
    Microchimica Acta, 2017, 184 : 2999 - 3006
  • [2] Voltammetric Sensing of Nifedipine Using a Glassy Carbon Electrode Modified with Carbon Nanofibers and Gold Nanoparticles
    Santos, Anderson M.
    Wong, Ademar
    Feitosa, Maria H. A.
    Cardenas-Riojas, Andy A.
    Calderon-Zavaleta, Sandy L.
    Baena-Moncada, Angelica M.
    Sotomayor, Maria D. P. T.
    Moraes, Fernando C.
    BIOSENSORS-BASEL, 2023, 13 (08):
  • [3] Voltammetric studies on the interaction of epinephrine with DNA base on a glassy carbon electrode modified with Au nanoparticles
    Xueliang Wang
    Jinjin Li
    Tao Wang
    Zhangyu Yu
    Ionics, 2015, 21 : 1105 - 1110
  • [4] Voltammetric studies on the interaction of epinephrine with DNA base on a glassy carbon electrode modified with Au nanoparticles
    Wang, Xueliang
    Li, Jinjin
    Wang, Tao
    Yu, Zhangyu
    IONICS, 2015, 21 (04) : 1105 - 1110
  • [5] Chronocoulometric DNA biosensor based on a glassy carbon electrode modified with gold nanoparticles, poly(dopamine) and carbon nanotubes
    Dong, Xiao
    Lu, Xiaocui
    Zhang, Keying
    Zhang, Yuzhong
    MICROCHIMICA ACTA, 2013, 180 (1-2) : 101 - 108
  • [6] Chronocoulometric DNA biosensor based on a glassy carbon electrode modified with gold nanoparticles, poly(dopamine) and carbon nanotubes
    Xiao Dong
    Xiaocui Lu
    Keying Zhang
    Yuzhong Zhang
    Microchimica Acta, 2013, 180 : 101 - 108
  • [7] Voltammetric determination of Cr(VI) using gold nanoparticles-modified glassy carbon electrode
    Wyantuti, Santhy
    Ishmayana, Safri
    Hartati, Yeni Wahyuni
    INTERNATIONAL SYMPOSIUM ON APPLIED CHEMISTRY 2015, 2015, 16 : 15 - 23
  • [8] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Shoaie, Nahid
    Forouzandeh, Mehdi
    Omidfar, Kobra
    MICROCHIMICA ACTA, 2018, 185 (04)
  • [9] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Nahid Shoaie
    Mehdi Forouzandeh
    Kobra Omidfar
    Microchimica Acta, 2018, 185
  • [10] Voltammetric Determination of Sulfonamides with a Modified Glassy Carbon Electrode Using Carboxyl Multiwalled Carbon Nanotubes
    He, Bao-Shan
    Chen, Wen-Bo
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (12) : 2216 - 2225