Energy Efficiency Optimization Design of a Forward-Swept Axial Flow Fan for Heat Pump

被引:5
|
作者
Yang, Ke [1 ,2 ,3 ]
Zhou, Shuiqing [1 ,2 ,3 ]
Hu, Yinjie [1 ,2 ,3 ]
Zhou, Huaxin [1 ,2 ,3 ]
Jin, Weiya [1 ,2 ,3 ]
机构
[1] Zhejiang Univ Technol, Coll Mech Engn, Hangzhou, Peoples R China
[2] Inst Innovat Res Shengzhou, Shengzhou, Peoples R China
[3] Zhejiang Univ Technol, Shengzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
forward-swept axial fan; energy conservation design; forward-swept curve parameterization; ensemble of surrogates; multi-objective optimization; NOISE; SHAPE;
D O I
10.3389/fenrg.2021.700365
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As one of the key components of the heat pump system, compared to that of a conventional axial fan, the blade tip area of a forward-swept axial fan is much larger than its blade root, which is the main noise source of the fan and also has an important influence on the fan efficiency. Enhancement of the aerodynamic performance and efficiency of a forward-swept axial fan was addressed by utilizing the Bezier function to parameterize the forward-swept curve on blade tops. In order to quickly select an agent model suitable for the project, an ES model was established by integration of the radial basis function model and the Kriging model. When NSGA-II was combined, multi-objective optimization was carried out with the flow rate and total pressure efficiency as optimization goals. Analysis of optimization results revealed that the optimized axial flow fan's flow rate and total pressure efficiency were improved to some degree. At the design working point, the fan's flow rate increased by 1.78 m(3)/min, while the total pressure efficiency increased by 3.0%. These results lay solid foundation for energy saving of the heat pump system.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan
    Gong Hee Lee
    Je Hyun Baek
    Hwan Joo Myung
    Flow, Turbulence and Combustion, 2003, 70 : 241 - 265
  • [2] Structure of tip leakage flow in a forward-swept axial-flow fan
    Lee, GH
    Baek, JH
    Myung, HJ
    FLOW TURBULENCE AND COMBUSTION, 2003, 70 (1-4) : 241 - 265
  • [3] Mean velocity characteristics behind a forward-swept axial-flow fan
    Department of Mechanical Engineering, Pohang Univ. of Sci. and Technology, San 31, HyoJa Dong, Pohang, 790-784, Korea, Republic of
    JSME Int. J. Ser. B Fluids Therm. Eng., 3 (476-488):
  • [4] Mean velocity characteristics behind a forward-swept axial-flow fan
    Myung, HJ
    Baek, JH
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1999, 42 (03) : 476 - 488
  • [5] Effect of blade loading on the structure of tip leakage flow in a forward-swept axial-flow fan
    Lee, GH
    Baek, JH
    Myung, HJ
    HVAC&R RESEARCH, 2005, 11 (01): : 95 - 117
  • [6] Forward-swept fan moves ahead
    Ashley, S
    MECHANICAL ENGINEERING, 1996, 118 (11) : 142 - 142
  • [7] OPTIMIZATION OF A FORWARD-SWEPT COMPLIANT MECHANISM
    Calogero, Joseph
    Frecker, Mary
    Hasnain, Zohaib
    Hubbard, James E., Jr.
    PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, 2017, VOL 1, 2017,
  • [8] Velocity field measurements of swirl flow around a forward-swept axial fan using a phase-averaged PTV
    S. J. Lee
    J. Choi
    I. S. Lee
    Journal of Visualization, 2001, 4 : 257 - 265
  • [9] Velocity Field Measurements of Swirl Flow around a Forward-swept Axial Fan Using a Phase-averaged PTV
    Lee, S. J.
    Choi, J.
    Lee, I. S.
    JOURNAL OF VISUALIZATION, 2001, 4 (03) : 257 - 265
  • [10] Shock characteristics measured upstream of both a forward-swept and an aft-swept fan
    Podboy, Gary G.
    Krupar, Martin J.
    Sutliff, Daniel L.
    Horvath, Csaba
    Proceedings of the ASME Turbo Expo 2007, Vol 6, Pts A and B, 2007, : 1455 - 1478