Experimental investigation on the seismic response of a steel liquid storage tank equipped with floating roof by shaking table tests

被引:99
|
作者
De Angelis, M. [2 ]
Giannini, R. [1 ]
Paolacci, F. [1 ]
机构
[1] Univ Roma Tre, Dept Struct, I-00146 Rome, Italy
[2] Univ Roma La Sapienza, Dept Struct & Geotech Engn, Rome, Italy
来源
关键词
steel storage tanks; floating roof; shaking table test; base isolation; CYLINDRICAL TANKS; EARTHQUAKE;
D O I
10.1002/eqe.945
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the effectiveness of the base isolation on steel storage tanks has been investigated through numerical models and then checked by shaking table tests on a reduced scale (1:14) model of a real steel tank, typically used in petrochemical plants. In the experimental campaign the floating roof has also been taken into account. The tests have been performed on the physical model both in fixed and isolated base configurations; in particular two alternative base isolation systems have been used: high-damping rubber bearings devices and sliding isolators with elasto-plastic dampers. Finally, a comparison between experimental and numerical results has also been performed. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:377 / 396
页数:20
相关论文
共 50 条
  • [1] Seismic risk assessment of liquid overtopping in a steel storage tank equipped with a single deck floating roof
    Caprinozzi, Stefano
    Paolacci, Fabrizio
    Dolsek, Matjaz
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2020, 67
  • [2] Shaking Table Test of Steel Cylindrical Liquid Storage Tank Considering the Roof Characteristics
    Doobyong Bae
    Jang Ho Park
    International Journal of Steel Structures, 2018, 18 : 1167 - 1176
  • [3] Shaking Table Test of Steel Cylindrical Liquid Storage Tank Considering the Roof Characteristics
    Bae, Doobyong
    Park, Jang Ho
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2018, 18 (04) : 1167 - 1176
  • [4] Experimental investigation of the seismic response of moment-resisting steel frames using shaking table tests
    Balaskas, G.
    Lenzen, N.
    Kolisch, F.
    Hoffmeister, B.
    Klinkel, S.
    BAUINGENIEUR, 2025, 100 (1-2):
  • [5] MODEL TESTS ON SLOSHING OF A FLOATING ROOF IN A CYLINDRICAL LIQUID STORAGE TANK UNDER SEISMIC EXCITATION
    Nagaya, Takashi
    Matsui, Tetsuya
    Wakasa, Takuo
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 4, 2009, : 391 - 399
  • [6] Seismic performance of a floating roof in an unanchored broad storage tank: Experimental tests and numerical simulations
    Caprinozzi, Stefano
    Paolacci, Fabrizio
    Bursi, Oreste S.
    Dolsek, Matjaz
    JOURNAL OF FLUIDS AND STRUCTURES, 2021, 105
  • [7] Floating Roof Influence on Seismic Response of Large Vertical Storage Tank
    Sun, Ying
    Sun, Jiangang
    Cui, Lifu
    CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 1399 - +
  • [8] Seismic response analysis models of an oil storage tank with a floating roof
    Nagashima, Toshio
    Tsukuda, Takenari
    Suemasu, Hiroshi
    Sogabe, Kiyoshi
    ENGINEERING COMPUTATIONS, 2011, 28 (5-6) : 701 - 716
  • [9] Experimental investigation of liquid-tank interaction effects on full containment LNG storage tanks through shaking table tests
    Liu, Wei
    Xiao, Chang
    Zhou, Hao
    Wang, Chenyan
    THIN-WALLED STRUCTURES, 2024, 196
  • [10] Seismic Response of a Large LNG Storage Tank Based on a Shaking Table Test
    Chen, Zengshun
    Xu, Zhengang
    Liu, Yang
    Fu, Jun
    Cheng, Huayan
    Zhang, Likai
    Xue, Xuanyi
    APPLIED SCIENCES-BASEL, 2022, 12 (15):