Predictors of adoption and impact of evidence-based programming on the incidence of implantable cardioverter-defibrillator therapies

被引:0
|
作者
Loughlin, Gerard [1 ,2 ]
Datino, Tomas [1 ]
Arenal, Angel [1 ]
Ruiz-Granell, Ricardo [3 ]
Miguel Sanchez-Gomez, Juan [3 ]
Perez, Luisa [4 ]
Martinez-Ferrer, Jose [5 ]
Alzueta, Javier [6 ]
Perez-Lorente, Fernando [7 ]
Vinolas, Xavier [8 ]
Fidalgo Andres, Maria Luisa [9 ]
Fernandez de la Concha, Joaquin [10 ]
机构
[1] Hosp Gen Univ Gregorio Maranon, Serv Cardiol, Dr Esquerdo 46, Madrid 28007, Spain
[2] Complejo Hosp Univ Toledo, Serv Cardiol, Unidad Arritmias, Toledo, Spain
[3] Hosp Clin Univ Valencia, Serv Cardiol, Valencia, Spain
[4] Complexo Hosp Univ A Coruna, Serv Cardiol, La Coruna, Spain
[5] Hosp Univ Araba, Serv Cardiol, Vitoria, Spain
[6] Hosp Virgen Victoria, Serv Cardiol, Malaga, Spain
[7] Hosp Reina Sofia, Serv Cardiol, Murcia, Spain
[8] Hosp Santa Creu & Sant Pau, Serv Cardiol, Barcelona, Spain
[9] Hosp Univ Leon, Serv Cardiol, Unidad Arritmias, Leon, Spain
[10] Hosp Infanta Cristina, Serv Cardiol, Badajoz, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2021年 / 74卷 / 04期
关键词
ICD programming; ADVANCE III; Adoption of evidence; ICD therapy;
D O I
10.1016/j.recesp.2020.06.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: The ADVANCE III trial showed that a delayed-detection strategy reduces implantable cardioverter-defibrillator (ICD) therapies. Here, we describe the adherence to and predictors of ADVANCE adoption and compare ICD therapy rates between patients with and without ADVANCE programming. Methods: This observational retrospective study analyzed patients implanted with Medtronic ICDs included from 2005 to 2016 in a Spanish national multicenter registry (UMBRELLA database; ClinicalTrials.gov, NCT01561144). Changes in ADVANCE programming adoption were described in relation to a) publication of the ADVANCE trial, b) implementation of an "ADVANCE awareness" campaign, and c) publication of an expert consensus statement. Multivariate logistic regression identified predictors of adoption. Therapy incidence rates were compared between groups by estimating the adjusted incidence rate ratio (aIRR) using negative binomial regression. Results: A total of 3528 patients were included. An ADVANCE strategy was used in 20% overall and in 44% at the end of the study. ADVANCE III adoption increased after trial publication, with less growth after an "ADVANCE awareness" campaign and after expert consensus statement publication. Predictors of ADVANCE adoption were as follows: ICD device with a nominal number of intervals to detect 30/40 (aOR, 4.4; 95%CI, 3.5-5.4), implantation by an electrophysiologist (aOR, 1.7; 95%CI, 1.4-2.2), and secondary prevention (aOR, 3.2; 95%CI, 2.6-3.9). Dual-chamber ICDs (aOR, 0.6; 95%CI, 0.5-0.8) and cardiac resynchronization-defibrillators (aOR, 0.5; 95%CI, 0.4-0.7) were associated with lower adoption. ADVANCE programming was associated with reduced total therapy burden (aIRR, 0.77; 95%CI, 0.69-0.86) and fewer inappropriate shocks (aIRR, 0.66; 95%CI, 0.52-0.85). Conclusions: ADVANCE adoption remains modest and can be improved through evidence-driven selection of nominal ICD settings. ADVANCE programming is associated with reduced therapy rates in real-world ICD recipients. (C) 2020 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [1] Inappropriate Implantable Cardioverter-Defibrillator Shocks Incidence, Predictors, and Impact on Mortality
    van Rees, Johannes B.
    Borleffs, C. Jan Willem
    de Bie, Mihaly K.
    Stijnen, Theo
    van Erven, Lieselot
    Bax, Jeroen J.
    Schalij, Martin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (05) : 556 - 562
  • [2] Feedback to providers improves evidence-based implantable cardioverter-defibrillator programming and reduces shocks
    Silver, Marc T.
    Sterns, Laurence D.
    Piccini, Jonathan P.
    Joung, Boyoung
    Ching, Chi-Keong
    Pickett, Robert A.
    Rabinovich, Rafael
    Liu, Shufeng
    Peterson, Brett J.
    Lexcen, Daniel R.
    HEART RHYTHM, 2015, 12 (03) : 545 - 553
  • [3] Adopting evidence-based optimal implantable cardioverter-defibrillator programming: Overcoming the inertia COMMENT
    Stiles, Martin K.
    HEART RHYTHM, 2022, 19 (02) : 226 - 227
  • [4] Incidence of and predictors for appropriate implantable cardioverter-defibrillator therapy in patients with a secondary preventive implantable cardioverter-defibrillator indication
    Schaer, Beat
    Kuehne, Michael
    Reichlin, Tobias
    Osswald, Stefan
    Sticherling, Christian
    EUROPACE, 2016, 18 (02): : 227 - 231
  • [5] INCIDENCE AND PREDICTORS OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPIES IN AMBULATORY PATIENTS WITH VENTRICULAR ASSIST DEVICES
    Aktas, Mehmet
    Koneru, Sushma
    Shah, Abrar
    Shah, Samit
    Massey, Todd
    Chen, Leway
    Huang, David T.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [6] Right Ventricular Dysfunction and the Incidence of Implantable Cardioverter-Defibrillator Therapies
    Aktas, Mehmet K.
    Kim, David D.
    McNitt, Scott
    Huang, David T.
    Rosero, Spencer Z.
    Hall, Burr W.
    Zareba, Wojciech
    Daubert, James P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (12): : 1501 - 1508
  • [7] Predictors of Shock-Reduction Programming and Its Impact on Implantable Cardioverter-Defibrillator Therapies and Mortality: The CERTITUDE Registry
    Beyer, Sebastian E.
    Harrell, Camden
    Mullane, Steven
    Kutyifa, Valentina
    Madhavan, Malini
    Piccini, Jonathan P.
    Upadhyay, Gaurav A.
    Ip, James E.
    Thomas, George
    Liu, Christopher F.
    Markowitz, Steven M.
    Hayes, David
    Lerman, Bruce B.
    Cheung, Jim W.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (15):
  • [8] Improving adoption of evidence-based implantable cardioverter defibrillator programming: A single-center experience
    Khan, Parisha
    Gopinath, Binoob
    Jahagirdar, Nishat
    Laybourn, Micaela
    Cannata, Antonio
    Bromage, Daniel I.
    Murgatroyd, Francis
    Scott, Paul A.
    HEART RHYTHM, 2022, 19 (06) : 1011 - 1012
  • [9] PREDICTORS OF INAPPROPRIATE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR DISCHARGES
    Catanzaro, John N.
    Makaryus, Amgad
    Makaryus, John
    Sison, Cristina
    Vavasis, Christos
    Donaldson, David
    Altman, Erik
    Beldner, Stuart
    Jadonath, Ram
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E172 - E172
  • [10] Impact of the implantable cardioverter-defibrillator on rehospitalizations
    Valenti, R
    Schlapfer, J
    Fromer, M
    Fischer, A
    Kappenberger, L
    EUROPEAN HEART JOURNAL, 1996, 17 (10) : 1565 - 1571