PREDICTORS OF PARTIAL WEIGHT-BEARING PERFORMANCE AFTER TOTAL HIP ARTHROPLASTY

被引:11
|
作者
Hurkmans, Henri L. [1 ]
Bussmann, Johannes B. [2 ]
Benda, Eric [1 ]
Haisma, Janneke A. [2 ]
Verhaar, Jan A. [3 ]
Stam, Henk J. [2 ]
机构
[1] Erasmus MC, Univ Med Ctr Rotterdam, Dept Phys Therapy, NL-3015 CE Rotterdam, Netherlands
[2] Erasmus MC, Univ Med Ctr, Dept Rehabil Med, NL-3015 CE Rotterdam, Netherlands
[3] Erasmus MC, Univ Med Ctr, Dept Orthoped Surg, NL-3015 CE Rotterdam, Netherlands
关键词
weight-bearing; hip arthroplasty; physical therapy; rehabilitation; multilevel modelling; VERTICAL FORCE MEASUREMENTS; PEDAR MOBILE SYSTEM; ASSISTIVE DEVICES; LOWER-EXTREMITY; WALKING; AMBULATION; MUSCLE; WEIGHTBEARING; CRUTCHES; FRACTURE;
D O I
10.2340/16501977-0480
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To determine which patient characteristics, postoperative characteristics, and walking features influence patients' partial weight-bearing performance after total hip arthroplasty. Design: A descriptive prospective study. Patients: Fifty patients with total hip arthroplasty were included; partial weight-bearing was performed at a 10% body weight target load (n=33) and at a 50% body weight target load (n=17). Methods: Patient (age, gender, body weight, upper arm muscle strength) and postoperative (pain, fatigue, anxiety) characteristics, and walking features (step frequency, total walking time, total number of steps, walking aid) were measured postoperatively on day 7 (with and without a physical therapist) and on day 21 (at home). Multilevel regression analyses were conducted to identify determinants that influence partial weight-bearing. Results: Gender (female) (regression coefficient B=8.18, p=0.03) and total walking time (B=0.58,p<0.001) were positively, and pain during walking was negatively (B=-2.43, p=0.02), associated with the mean peak load. For partial weight-bearing at 10% body weight, postoperative overall anxiety (B=6.40, p=0.002) and total steps (B=0.05, p=0.02) were positively associated with the percentage of steps above the target load. For partial weight-bearing at home, postoperative overall anxiety was negatively associated with the percentage of steps above the target load (B=-5.32, p=0.001). Conclusion: Gender, pain during walking, walking time, postoperative anxiety and total number of steps influence the patient's partial weight-bearing performance.
引用
收藏
页码:42 / 48
页数:7
相关论文
共 50 条
  • [1] Full weight-bearing after cementless total hip arthroplasty
    Kishida, Y
    Sugano, N
    Sakai, T
    Nishii, T
    Haraguchi, K
    Ohzono, K
    Yoshikawa, H
    INTERNATIONAL ORTHOPAEDICS, 2001, 25 (01) : 25 - 28
  • [2] Full weight-bearing after cementless total hip arthroplasty
    Y. Kishida
    N. Sugano
    T. Sakai
    T. Nishii
    K. Haraguchi
    K. Ohzono
    H. Yoshikawa
    International Orthopaedics, 2001, 25 : 25 - 28
  • [3] WEIGHT-BEARING RADIOGRAPHY IN TOTAL HIP-ARTHROPLASTY
    TURULA, K
    FRIBERG, O
    HAAJANEN, J
    LINDHOLM, TS
    TALLROTH, K
    ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (06): : 581 - 581
  • [4] Utility of Upright Weight-bearing Imaging in Total Hip Arthroplasty
    DelSole, Edward M.
    Mercuri, John J.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2019, 23 (06) : 603 - 608
  • [5] The Recovery of Weight-Bearing Symmetry After Total Hip Arthroplasty Is Activity-Dependent
    Alves, Sonia A.
    Preusse, Marco
    Hommel, Hagen
    Duda, Georg N.
    Agres, Alison N.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [6] Biofeedback Training for Partial Weight Bearing in Patients After Total Hip Arthroplasty
    Pataky, Zoltan
    Rodriguez, Diego De Leon
    Golay, Alain
    Assal, Mathieu
    Assal, Jean-Philippe
    Hauert, Claude-Alain
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (08): : 1435 - 1438
  • [7] The effect of weight-bearing on the radiographic measurement of the position of the femoral head after total hip arthroplasty
    Moore, KD
    Barrack, RL
    Sychterz, CJ
    Sawhney, J
    Yang, AM
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (01): : 62 - 69
  • [8] The effect of partial or full weight bearing ambulation after cementless total hip arthroplasty
    Woolson, ST
    Adler, NS
    JOURNAL OF ARTHROPLASTY, 2002, 17 (07): : 820 - 825
  • [9] WEIGHT-BEARING AFTER HIP SURGERY
    TAILLARD, W
    SOUTH AFRICAN MEDICAL JOURNAL, 1973, 47 (44): : 2139 - 2140
  • [10] Outcomes and Weight-bearing Status During Rehabilitation After Arthroplasty for Hip Fractures
    Siebens, Hilary C.
    Sharkey, Phoebe
    Aronow, Harriet U.
    Horn, Susan D.
    Munin, Michael C.
    DeJong, Gerben
    Smout, Randall J.
    Radnay, Craig S.
    PM&R, 2012, 4 (08) : 548 - 555