Dosimetry Commissioning of Tunisian Electron Beam Accelerator

被引:2
|
作者
Mejri, A. [1 ]
Farah, K. [1 ]
Hosni, F. [1 ]
Chatti, J. [1 ]
Trabelsi, H. [2 ]
Trabelsi, Z. [2 ]
Kraiem, M. [2 ]
机构
[1] CNSTN, Lab Dosimetrie Rayonnements Ionisants, Sidi Thabet 2020, Tunisia
[2] Lab Radio Traitement CNSTN, Sidi Thabet, Tunisia
关键词
Dosimetry commissioning; E-beam accelerator; Dose uniformity; IRRADIATOR; RADIATION; GEANT4;
D O I
10.1007/s13369-015-1866-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The Tunisian Beta irradiation facility (LINAC, CIRCE III) has been put into operation at the end of 2009. Such facility is designed essentially for sterilization of medical devices and conservation of foodstuff. The delivery and validation of a specified dose are key concerns of operators of electron beam irradiation facilities. In order to adjust the treatment conditions and to control the optimal operation of the accelerator, it is necessary to evaluate the absorbed dose and its distribution within material in the radiation field. Consequently, aspects from installation qualification to operation qualification are described together with the associated process variables. Technical parameters that directly influence the absorbed dose distribution in the product were examined by dosimetric measurements and compared to the data specified by the facility manufacturer. Two dosimeter types were used for measurements: radiochromic B3 and cellulose triacetate films.
引用
收藏
页码:2333 / 2338
页数:6
相关论文
共 50 条
  • [1] Dosimetry Commissioning of Tunisian Electron Beam Accelerator
    A. Mejri
    K. Farah
    F. Hosni
    J. Chatti
    H. Trabelsi
    Z. Trabelsi
    M. Kraiem
    Arabian Journal for Science and Engineering, 2016, 41 : 2333 - 2338
  • [2] Chemical dosimeters for electron beam dosimetry of microtron accelerator
    Praveen Joseph
    Rajesha Nairy
    Santhosh Acharya
    Ganesh Sanjeev
    Y. Narayana
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 1013 - 1019
  • [3] CELLOPHANE DOSIMETRY OF ELECTRON BEAM GENERATED BY VANDEGRAAFF ACCELERATOR
    CHEN, TJ
    YEH, SJ
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1965, 12 (04) : 127 - &
  • [4] Chemical dosimeters for electron beam dosimetry of microtron accelerator
    Joseph, Praveen
    Nairy, Rajesha
    Acharya, Santhosh
    Sanjeev, Ganesh
    Narayana, Y.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 302 (02) : 1013 - 1019
  • [5] DOSIMETRY MEASUREMENTS DURING THE COMMISSIONING OF THE GJ-2 ELECTRON-ACCELERATOR
    CHOSDU, R
    HILMY, N
    TOBING, R
    KICKY, LTK
    RAZZAK, M
    KOVACS, A
    MILLER, A
    RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6): : 1175 - 1179
  • [6] ACCELERATOR BEAM DOSIMETRY
    NELSON, WR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (04) : 1376 - 1378
  • [7] Results of beam parameter measurement of the ELBE electron accelerator after commissioning
    Teichert, J
    Büchner, A
    Evtushenko, P
    Gabriel, F
    Lehnert, U
    Michel, P
    Voigtländer, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 507 (1-2): : 354 - 356
  • [8] ELECTRON BEAM DOSIMETRY OF A 2-MEV VANDEGRAAFF ACCELERATOR
    SHUMWAY, BW
    GOLDEN, R
    RADIOLOGY, 1957, 68 (01) : 104 - 105
  • [9] Electron beam commissioning for a siemens PRIMUS accelerator for Monte Carlo treatment planning
    Qin, L
    Li, J
    Deng, J
    Paskalev, K
    Ding, M
    Fourkal, E
    Ma, C
    MEDICAL PHYSICS, 2003, 30 (06) : 1516 - 1516
  • [10] EVALUATION OF ELECTRON-BEAM UNIFORMITY DURING COMMISSIONING OF A LINEAR-ACCELERATOR
    MANDELZWEIG, Y
    FEYGELMAN, V
    MEDICAL PHYSICS, 1993, 20 (04) : 1233 - 1236