Experience of 3 types of commercially available photodiode array in the daresbury laboratory energy dispersive EXAFS detector system

被引:3
|
作者
Salvini, G
Dent, AJ
Farrow, RC
Derbyshire, GE
Bogg, D
机构
[1] CCLRC Daresbury Laboratory
来源
JOURNAL DE PHYSIQUE IV | 1997年 / 7卷 / C2期
关键词
D O I
10.1051/jp4/1997210
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The technique of Energy Dispersive EXAFS is well established as an excellent tool for dynamic measurements. Daresbury Laboratory has developed a photodiode array based detector system for synchrotron radiation Energy Dispersive EXAFS experiments which allows high quality data to be collected in time scales of less than a second [1]. In order to provide the highest quality system the performance of 3 different commercially available photodiode arrays has been evaluated. This paper presents the results of these evaluations and indicates the future direction of this project.
引用
收藏
页码:319 / 320
页数:2
相关论文
共 6 条
  • [1] Characterisation of Reticon and Hamamatsu Photodiode array and the subsequent development of high performance VME-based detector systems optimised for Energy Dispersive EXAFS
    CCLRC Daresbury Lab, Warrington, United Kingdom
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 392 (1-3): : 461 - 464
  • [2] Characterisation of Reticon and Hamamatsu Photodiode array and the subsequent development of high performance VME-based detector systems optimised for Energy Dispersive EXAFS
    Bogg, D
    Dent, AJ
    Derbyshire, GE
    Farrow, RC
    Ramsdale, CA
    Salvini, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 461 - 464
  • [3] High performance VME-based detector system for subsecond energy dispersive EXAFS
    Salvini, G.
    Bogg, D.
    Dent, A.J.
    Derbyshire, G.E.
    Farrow, R.C.
    Felton, A.
    Ramsdale, C.
    Physica B: Condensed Matter, 1995, 208-209 (1-4):
  • [4] A HIGH-PERFORMANCE VME-BASED DETECTOR SYSTEM FOR SUBSECOND ENERGY-DISPERSIVE EXAFS
    SALVINI, G
    BOGG, D
    DENT, AJ
    DERBYSHIRE, GE
    FARROW, RC
    FELTON, A
    RAMSDALE, C
    PHYSICA B, 1995, 208 (1-4): : 229 - 231
  • [5] A VME-BASED PHOTODIODE ARRAY SYSTEM FOR ENERGY DISPERSIVE EXTENDED X-RAY ABSORPTION FINE-STRUCTURE
    DERBYSHIRE, GE
    BOGG, D
    DENT, AJ
    FARROW, RC
    GREAVES, GN
    HELSBY, WI
    MORRELL, C
    RAMSDALE, CA
    WELLS, MP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 790 - 791
  • [6] 20-ELEMENT HGI2 ENERGY DISPERSIVE-X-RAY ARRAY DETECTOR SYSTEM
    IWANCZYK, JS
    DORRI, N
    WANG, M
    SZCZEBIOT, RW
    DABROWSKI, AJ
    HEDMAN, B
    HODGSON, KO
    PATT, BE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) : 1275 - 1280