Laparoscopic implantation of electrodes for bilateral neuromodulation of the pudendal nerves and S3 nerve roots for treating pelvic pain and voiding dysfunction

被引:10
|
作者
Li, Adrienne L. K. [1 ]
Marques, Renato [2 ]
Oliveira, Acary [3 ]
Veloso, Laise [2 ]
Girao, Manoel J. B. C. [2 ]
Lemos, Nucelio [1 ,2 ]
机构
[1] Univ Toronto, Dept Obstet & Gynecol Funct Pelv Surg & Neuropelv, Toronto, ON, Canada
[2] Univ Fed Sao Paulo, Dept Gynecol, Pelv Neurodysfunct Unit, Rua Jose de Magalhaes,373 Ap904, BR-04026090 Sao Paulo, SP, Brazil
[3] Univ Fed Sao Paulo, Dept Neurol & Neurosurg, Neuromuscular Dis Unit, Sao Paulo, Brazil
关键词
Chronic pelvic pain; Neuromodulation; Pudendal; LION procedure; Laparoscopy; VASCULAR ENTRAPMENT; PREVALENCE; SYMPTOMS; SERIES;
D O I
10.1007/s00192-017-3411-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The procedure began with the removal of two previously placed InterStims. A quadripolar electrode was then laparoscopically inserted into Alcock's canal and attached to the pelvic pectineal line. Another lead was placed juxtaneurally to S3. Lead contacts were then exteriorized, and the peritoneum closed. The same procedure was then performed on the contralateral side. The leads were connected to a 16-pole rechargeable pulse generator. Postoperatively, the patient developed an acute dissection and partial thrombosis of the external iliac artery, which was treated endovascularly. Complete pain resolution was observed with simultaneous S3 and pudendal stimulation, with pudendal stimulation turned off for voiding. We conclude that laparoscopic implantation of neuromodulation electrodes allows simultaneous stimulation of S3 and pudendal nerves, providing more programming options and possibly increasing success rates in complex pelvic floor dysfunction cases.
引用
收藏
页码:1061 / 1064
页数:4
相关论文
共 9 条
  • [1] Laparoscopic implantation of electrodes for bilateral neuromodulation of the pudendal nerves and S3 nerve roots for treating pelvic pain and voiding dysfunction
    Adrienne L. K. Li
    Renato Marques
    Acary Oliveira
    Laise Veloso
    Manoel J. B. C. Girão
    Nucelio Lemos
    International Urogynecology Journal, 2018, 29 : 1061 - 1064
  • [2] LAPAROSCOPIC IMPLANTATION OF ELECTRODES FOR BILATERAL NEURMODULATION OF THE PUDENDAL NERVES AND S3 NERVE ROOTS FOR THE TREATMENT OF PELVIC PAIN AND VOIDING DYSFUNCTION
    Lemos, N.
    Marques, R.
    Oliveira, A.
    Girao, M.
    NEUROUROLOGY AND URODYNAMICS, 2014, 33 (06) : 1000 - 1001
  • [3] Laparoscopic implantation of neural electrodes on pelvic nerves: an experimental study on the obturator nerve in a chronic minipig model
    Rabischong, Benoit
    Larrain, Demetrio
    Rabischong, Pierre
    Botchorishvili, Revaz
    Fraisse, Georges
    Gallego, Stephane
    Gaydier, Philippe
    Chardigny, Jean Michel
    Avan, Paul
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (11): : 3706 - 3712
  • [4] Laparoscopic implantation of neural electrodes on pelvic nerves: an experimental study on the obturator nerve in a chronic minipig model
    Benoit Rabischong
    Demetrio Larraín
    Pierre Rabischong
    Revaz Botchorishvili
    Georges Fraisse
    Stephane Gallego
    Philippe Gaydier
    Jean Michel Chardigny
    Paul Avan
    Surgical Endoscopy, 2011, 25 : 3706 - 3712
  • [5] Laparoscopic treatment of intrapelvic entrapment of sacral nerve roots by abnormal piriformis bundles causing sciatica, pudendal neuralgia, and pelvic floor dysfunction
    Li, A.
    Polesello, G.
    Tokechi, D.
    Cancelliere, L.
    Sermer, C.
    Lemos, N.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2018, 29 : S78 - S79
  • [6] LAPAROSCOPIC TREATMENT OF INTRAPELVIC ENTRAPMENT OF SACRAL NERVE ROOTS BY ABNORMAL PIRIFORMIS BUNDLES CAUSING SCIATICA, PUDENDAL NEURALGIA, PELVIC FLOOR DYSFUNCTION, AND LOWER URINARY TRACT SYMPTOMS
    Li, A. L. K.
    Polesello, G.
    Tokechi, D.
    Cancelliere, L.
    Sermer, C.
    Lemos, N.
    NEUROUROLOGY AND URODYNAMICS, 2018, 37 : S239 - S240
  • [7] Development of a CT-guided standard approach for tined lead implantation at the sacral nerve root S3 in minipigs for chronic neuromodulation
    Foditsch, Elena Esra
    Zimmermann, Reinhold
    RESEARCH AND REPORTS IN UROLOGY, 2016, 8 : 169 - 173
  • [8] Bilateral S3 nerve stimulation, a minimally invasive alternative treatment for postoperative stress incontinence after implantation of an anterior root stimulator with posterior rhizotomy: a preliminary observation
    Everaert, K
    Derie, A
    Van Laere, M
    Vandekerckhove, T
    SPINAL CORD, 2000, 38 (04) : 262 - 264
  • [9] Bilateral S3 nerve stimulation, a minimally invasive alternative treatment for postoperative stress incontinence after implantation of an anterior root stimulator with posterior rhizotomy: a preliminary observation
    K Everaert
    A Derie
    M Van Laere
    T Vandekerckhove
    Spinal Cord, 2000, 38 : 262 - 264