The CMS Collaboration has approved the installation of an additional set of muon detectors based on triple-GEM technology in the first endcap muon station known as GE1/1. The chambers are currently under construction and will be installed in 2019 during the second Long Shutdown (LS2) planned by LHC. About half of the required 144 chambers have been already built by different production sites in Europe, Asia and the United States. Systematic inspections and strict quality controls, scheduled for the GE1/1 chambers approval by the central site (CERN), were carried out successfully in Bari and Frascati (Italy). The results of the quality control procedures concerning the effective gain and the response uniformity of the delivered detectors will be shown together with the results on other relevant parameters like internal pressure drop and maximum spurious signal rate.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Production and quality control of the new chambers with GEM technology in the CMS Muon System
    Venditti, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 476 - 478
  • [2] The Triple GEM Detector Control System for CMS forward muon spectrometer upgrade
    Ahmed, W.
    Abbaneo, D.
    Abbas, M.
    Abbrescia, M.
    Abdelalim, A. A.
    Aki, M. Abi
    Acosta, D.
    Ahmad, A.
    Ahmed, W.
    Aleksandrov, A.
    Aly, R.
    Altieri, P.
    Asawatangtrakuldee, C.
    Aspe, P.
    Assran, Y.
    Awan, I.
    Bally, S.
    Ban, Y.
    Banerjee, S.
    Barashko, V.
    Barria, P.
    Bencze, G.
    Beni, N.
    Benussi, L.
    Bhopatkar, V.
    Bianco, S.
    Bos, J.
    Bouhali, O.
    Holme, O.
    Braghieri, A.
    Braibant, S.
    Buontempo, S.
    Khan, S. A.
    Calabria, C.
    Caponero, M.
    Caputo, C.
    Cassese, F.
    Castaneda, A.
    Cauwenbergh, S.
    Cavallo, F. R.
    Celik, A.
    Choi, M.
    Choi, S.
    Christiansen, J.
    Cimmino, A.
    Colafranceschi, S.
    Colaleo, A.
    Garcia, A. Conde
    Czellar, S.
    Dabrowski, M. M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [3] Upgrade of the CMS Muon Spectrometer in the forward region with the GEM technology
    Bianco, M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (09):
  • [4] GEM detectors characterisation for the upgrade of the CMS muon system
    Simone, F.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (2-3):
  • [5] GEM detectors for the Upgrade of the CMS Muon Forward system
    Mocellin, Giovanni
    4TH INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS (ICPPA-2018), 2019, 1390
  • [6] Production and quality control of the Barrel RPC chambers of the CMS experiment
    Abbrescia, M
    Cavallo, E
    Colaleo, A
    Iaselli, G
    Loddo, F
    Maggi, M
    Marangelli, B
    Natali, S
    Nuzzo, S
    Pulgliese, G
    Ranieri, A
    Romano, F
    Trentadue, R
    Cavallo, N
    Comunale, G
    Fabozzi, F
    Paolucci, P
    Piccolo, D
    Sciacca, C
    Belli, G
    De Vecchi, C
    Guida, R
    Ratti, SP
    Riccardi, G
    Torre, P
    Vitulo, P
    Young, B
    Tao, LH
    Si-Jin, Q
    Yan-Lin, Y
    Jun, Y
    Anguelov, T
    Guenchev, V
    Panev, B
    Piperov, S
    Sultanov, G
    Vankov, P
    Dimitrov, A
    Glushkov, I
    Litov, L
    Nasteva, I
    Pavlov, B
    Petkov, P
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 290 - 294
  • [7] CMS Endcap Muon System Cathode Strip Chambers
    Vorobiev, I.
    2007 EUROPHYSICS CONFERENCE ON HIGH ENERGY PHYSICS, PTS 1-12, 2008, 110
  • [8] Cathode strip chambers for the CMS endcap muon system
    Hauser, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 384 (01): : 207 - 210
  • [9] Layout and assembly technique of the GEM chambers for the upgrade of the CMS first muon endcap station
    Abbaneo, D.
    Abbas, D.
    Abbrescia, M.
    Abdalla, H.
    Ahmad, A.
    Ahmed, A.
    Ahmed, W.
    Ali, C.
    Asghar, I
    Aspell, P.
    Assran, Y.
    Avila, C.
    Ban, Y.
    Band, R.
    Bansal, S.
    Bencze, G.
    Beni, N.
    Benussi, L.
    Bhatnagar, V
    Bhopatkar, V
    Bianco, M.
    Bianco, S.
    Borgonovi, L.
    Bouhali, O.
    Braghieri, A.
    Braibant-Giacomelli, S.
    Bravo, C.
    Cafaro, V
    Calabria, C.
    Salazar, C.
    Caponero, M.
    Cassese, F.
    Hernandez, A.
    Cavallo, F.
    Cavallo, N.
    Choi, Y.
    Colafranceschi, S.
    Colaleo, A.
    Garcia, A. Conde
    Dalchenko, M.
    De Lentdecker, G.
    Olio, D. Dell
    De Robertis, G.
    Dildick, S.
    Dorney, B.
    Endroczi, G.
    Erbacher, R.
    Errico, F.
    Fallavollita, F.
    Fontanesi, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 918 : 67 - 75
  • [10] Characterization of GEM Detectors for Application in the CMS Muon Detection System
    Abbaneo, D.
    Bally, S.
    Postema, H.
    Garcia, A. Conde
    Chatelain, J. P.
    Faber, G.
    Ropelewski, L.
    David, E.
    Pinto, S. Duarte
    Croci, G.
    Alfonsi, M.
    van Stenis, M.
    Sharma, A.
    Benussi, L.
    Bianco, S.
    Colafranceschi, S.
    Piccolo, D.
    Saviano, G.
    Turini, N.
    Oliveri, E.
    Magazzu, G.
    Marinov, A.
    Tytgat, M.
    Zaganidis, N.
    Hohlmann, M.
    Gnanvo, K.
    Ban, Y.
    Teng, H.
    Cai, J.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1416 - 1422