Effect of exchange blood transfusion on oxygen saturation of neonates with severe neonatal jaundice by pulse oximetry

被引:0
|
作者
Shakur, Abubakar Muhammed [1 ]
Garba, Nuhu Abubakar [2 ]
Ahmadu, Ibrahim [1 ]
Apollos, Daniel [3 ]
Wada, Aminu [4 ]
Abdullahil, Safiya Garba [1 ]
Mohammed, Abdulsalam [4 ]
Asani, Mustafa O. [1 ]
Aliyu, Ibrahim [1 ]
机构
[1] Aminu Kano Teaching Hosp, Cardiopulm Unit, Dept Pediat, Kano, Nigeria
[2] Fed Med Ctr, Dept Pediat, Nguru, Nigeria
[3] Fed Teaching Hosp, Dept Pediat, Gombe, Nigeria
[4] Aminu Kano Teaching Hosp, Dept Pediat, Kano, Nigeria
关键词
Exchange blood transfusion; SpO(2); Neonate; Hypoxia; HYPERBILIRUBINEMIA; PATTERN;
D O I
10.4103/2221-6189.316675
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine if there was any difference in SpO2 readings during exchange blood transfusion (EBT). Methods: A prospective cross-sectional study of neonates with severe neonatal jaundice requiring EBT was conducted. Oxygen saturation was recorded before, immediately and 15 minutes after EBT by using a pulse oximeter. Results: This study included 30 neonates with 20 males and 10 females. The age ranged from 1 to 12 days with a mean of (5.4 +/- 2.9) days. Pre-EBT SpO(2) ranged from 90% to 98% with a mean value of (94.3 +/- 2.2)%; SpO(2) in the end of EBT ranged from 85% to 99% with a mean value of (94.1 +/- 3.2)%; SpO(2) at 15 minutes after EBT ranged from 77% to 99% with a mean value of (94.8 +/- 4.1)%. There was no significant difference between SpO(2) values at onset of EBT and either immediately or 15 minutes after EBT (P=0.770 and 0.422, respectively). SpO(2) showed no significant difference between neonates who were infused with blood of different storage times (<24 h or >= 24 h) at the onset of EBT (P=0.584), immediately (P>0.999) and 15 minutes after EBT (P=0.887). Besides, SpO(2) values were compariable in neonates with hematocrit <45% or >= 45% at the onset of EBT (P=0.284), immediately (P=0.118) and 15 minutes after EBT (P=0.868). Conclusions: EBT does not affect SpO(2) in neonates.
引用
收藏
页码:112 / 116
页数:5
相关论文
共 50 条
  • [1] Reflectance pulse oximetry from core body in neonates and infants: Comparison to arterial blood oxygen saturation and to transmission pulse oximetry
    Kugelman A.
    Wasserman Y.
    Mor F.
    Goldinov L.
    Geller Y.
    Bader D.
    Journal of Perinatology, 2004, 24 (6) : 366 - 371
  • [2] Blood haemoglobin and pulse oximetry oxygen saturation measurement error
    Crooks, C.
    West, J.
    Morling, J.
    Simmonds, M.
    Juurlink, I.
    Briggs, S.
    Cruickshank, S.
    Hammond-Pears, S.
    Shaw, D.
    Card, T.
    Fogarty, A.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [3] EVALUATION OF OXYGEN-SATURATION MONITORING BY PULSE OXIMETRY IN NEONATES IN THE DELIVERY SYSTEM
    DIMICH, I
    SINGH, PP
    ADELL, A
    HENDLER, M
    SONNENKLAR, N
    JHAVERI, M
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (08): : 985 - 988
  • [4] Severe neonatal hyperbilirubinemia and blood exchange transfusion
    Zahedpasha, Y
    Ahmadpour, M
    Ebrahimzadeh, N
    PEDIATRIC RESEARCH, 2003, 54 (04) : 566 - 566
  • [5] Factors Associated with Exchange Transfusion among Severe Neonatal Jaundice in Malaysia
    Hanafi, Wan Soliha Wan Mohd
    Ibrahim, Wan Norlida Wan
    Hashim, Noran
    IRANIAN JOURNAL OF NEONATOLOGY, 2021, 12 (03) : 7 - 12
  • [6] Effects of Motion Artifact on the Blood Oxygen Saturation Estimate in Pulse Oximetry
    Clarke, Geoffrey W. J.
    Chan, Adrian D. C.
    Adler, Andy
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 275 - 278
  • [7] Novel Pulse Oximetry Sonifications for Neonatal Oxygen Saturation Monitoring: A Laboratory Study
    Hinckfuss, Kelly
    Sanderson, Penelope
    Loeb, Robert G.
    Liley, Helen G.
    Liu, David
    HUMAN FACTORS, 2016, 58 (02) : 344 - 359
  • [8] Blood Exchange Transfusion for Infants with Severe Neonatal Hyperbilirubinemia
    Murki, Srinivas
    Kumar, Praveen
    SEMINARS IN PERINATOLOGY, 2011, 35 (03) : 175 - 184
  • [9] Reference Values of Capillary Blood Saturation in Neonates and its Difference from Pulse Oximetry
    Jesic, Milos M.
    Jesic, Maja D.
    Krstajic, Tamara D.
    Vujnovic, Zoran M.
    Cutura, Nedjo D.
    Maglajlic, Svjetlana S.
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2010, 138 (5-6) : 297 - 299
  • [10] Pulse Oximetry Overestimates Oxygen Saturation in COPD
    Amalakanti, Sridhar
    Pentakota, Mohan Rao
    RESPIRATORY CARE, 2016, 61 (04) : 423 - 427