Role of the source to building lateral separation distance in petroleum vapor intrusion

被引:18
|
作者
Verginelli, Iason [1 ]
Capobianco, Oriana [1 ]
Baciocchi, Renato [1 ]
机构
[1] Univ Roma Tor Vergata, Lab Environm Engn, Dept Civil Engn & Comp Sci Engn, Rome, Italy
关键词
Vapor intrusion; Lateral screening distance; Modeling; Aerobic biodegradation; EMPLACED FUEL SOURCE; OXYGEN-LIMITED BIODEGRADATION; VADOSE ZONE; CONTAMINANT VAPORS; AIRBASE VAERLOSE; SCREENING MODEL; HYDROCARBONS; DENMARK; SITES; ATTENUATION;
D O I
10.1016/j.jconhyd.2016.03.009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The adoption of source to building separation distances to screen sites that need further field investigation is becoming a common practice for the evaluation of the vapor intrusion pathway at sites contaminated by petroleum hydrocarbons. Namely, for the source to building vertical distance, the screening criteria for petroleum vapor intrusion have been deeply investigated in the recent literature and fully addressed in the recent guidelines issued by ITRC and U.S.EPA. Conversely, due to the lack of field and modeling studies, the source to building lateral distance received relatively low attention. To address this issue, in this work we present a steady-state vapor intrusion analytical model incorporating a piecewise first-order aerobic biodegradation limited by oxygen availability that accounts for lateral source to building separation. The developed model can be used to evaluate the role and relevance of lateral vapor attenuation as well as to provide a site-specific assessment of the lateral screening distances needed to attenuate vapor concentrations to risk-based values. The simulation outcomes showed to be consistent with field data and 3-D numerical modeling results reported in previous studies and, for shallow sources, with the screening criteria recommended by U.S.EPA for the vertical separation distance. Indeed, although petroleum vapors can cover maximum lateral distances up to 25-30 m, as highlighted by the comparison of model outputs with field evidences of vapor migration in the subsurface, simulation results by this new model indicated that, regardless of the source concentration and depth, 6 m and 7 m lateral distances are sufficient to attenuate petroleum vapors below risk-based values for groundwater and soil sources, respectively. However, for deep sources (>5 m) and for low to moderate source concentrations (benzene concentrations lower than 5 mg/L in groundwater and 0.5 mg/kg in soil) the above criteria were found extremely conservative as the model results indicated that for such scenarios the lateral screening distance may be set equal to zero. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:58 / 67
页数:10
相关论文
共 50 条
  • [1] Estimation of Contaminant Subslab Concentration in Vapor Intrusion Including Lateral Source-Building Separation
    Yao, Yijun
    Shen, Rui
    Pennell, Kelly G.
    Suuberg, Eric M.
    VADOSE ZONE JOURNAL, 2013, 12 (03):
  • [2] Influence of the lateral source/building separation on vapour intrusion: A numerical study
    Mora, Juan Sebastian Rios
    Collignan, Bernard
    Diallo, Thierno
    Abadie, Marc
    Limam, Karim
    12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [3] Physically simulating the effect of lateral vapor source-building separation on soil vapor intrusion: Influences of surface pavements and soil heterogeneity
    Wang, Genfu
    Xiao, Yuting
    Zuo, Jianping
    Wang, Yue
    Man, Jun
    Tang, Wei
    Chen, Qiang
    Ma, Shuaishuai
    Yao, Yijun
    JOURNAL OF CONTAMINANT HYDROLOGY, 2020, 235
  • [4] Vapor intrusion in buildings: Development of semi-empirical models including lateral separation between the building and the pollution source
    Juan Sebastian Rios Mora
    Thierno Diallo
    Bernard Collignan
    Marc Abadie
    Karim Limam
    Building Simulation, 2022, 15 : 2031 - 2049
  • [5] Vapor intrusion in buildings: Development of semi-empirical models including lateral separation between the building and the pollution source
    Mora, Juan Sebastian Rios
    Diallo, Thierno
    Collignan, Bernard
    Abadie, Marc
    Limam, Karim
    BUILDING SIMULATION, 2022, 15 (12) : 2031 - 2049
  • [6] Effect of vapor source - building separation and building construction on soil vapor intrusion as studied with a three-dimensional numerical model
    Abreu, LDV
    Johnson, PC
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (12) : 4550 - 4561
  • [7] Investigating the Role of Soil Texture in Petroleum Vapor Intrusion
    Yao, Yijun
    Mao, Fang
    Xiao, Yuting
    Chen, Huanyu
    Verginelli, Iason
    Luo, Jian
    JOURNAL OF ENVIRONMENTAL QUALITY, 2018, 47 (05) : 1179 - 1185
  • [8] Estimating the oxygenated zone beneath building foundations for petroleum vapor intrusion assessment
    Verginelli, Iason
    Yao, Yijun
    Wang, Yue
    Ma, Jie
    Suuberg, Eric M.
    JOURNAL OF HAZARDOUS MATERIALS, 2016, 312 : 84 - 96
  • [9] A source depletion model for vapor intrusion involving the influence of building characteristics
    Zhang, Ruihuan
    Jiang, Lin
    Zhong, Maosheng
    DeVaull, George
    Lahvis, Matthew A.
    Ma, Jie
    Zhou, Youya
    Zheng, Rui
    Fu, Quankai
    ENVIRONMENTAL POLLUTION, 2019, 246 : 864 - 872
  • [10] Vapor Intrusion Screening at Petroleum UST Sites
    Lahvis, Matthew A.
    Hers, Ian
    Davis, Robin V.
    Wright, Jackie
    DeVaull, George E.
    GROUND WATER MONITORING AND REMEDIATION, 2013, 33 (02): : 53 - 67